Brocade Fabric OS Message Reference Supporting Fabric OS v6.0.0 (53-1000600-01, October 2007)

Fabric OS Message Reference 79
53-1000600-01
EM-1006
12
EM-1006
Message <timestamp>, [EM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id>
has faulted. Sensor(s) below minimum limits.
Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade
is being shut down for environmental reasons; the voltage is too low.
Recommended
Action
If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the
blade.
If this problem occurs on a switch, it usually indicates a hardware problem on the main board;
replace the switch.
Severity CRITICAL
EM-1007
Message <timestamp>, [EM-1007], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id>
is being reset. Sensor(s) has exceeded max limits.
Probable Cause Indicates that the voltage on a switch has exceeded environmental limits. A reset is sent to the
faulty slot or the switch for nonbladed switches.
Recommended
Action
There is most likely a voltage hardware problem on the blade or motherboard of the switch.
For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU).
For the Brocade 3900 replace the motherboard FRU.
For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, AP7600, replace the switch.
Severity CRITICAL
EM-1008
Message <timestamp>, [EM-1008], <sequence-number>, FFDC, CRITICAL, <system-name>, Unit in
<FRU Id> faulted, incompatible with chassis option <chassis configuration option>.
Probable Cause Indicates that a blade inserted in the specified slot is not compatible with the switch chassisConfig
option. The blade is faulted.
Recommended
Action
Replace the blade. Make sure the replacement blade is compatible with your control processor (CP)
type and chassisConfig setting.
Severity CRITICAL