Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)

646 Fabric OS Command Reference
53-1001186-01
portShow
2
iac_credits_timestamp: 0x0000030DF1E6C770
iac_credits_time_savg: 907614 microseconds
iac_credits_time_max: 1000221 microseconds
iac_e2e_latency_savg: 81800 microseconds
iac_e2e_latency_max: 90074 microseconds
iac_credits_timer_abort: 0
iac_credits_timer_nobuff: 0
iac_hold_head = 0x00000000
iac_hold_tail = 0x00000000
Internal Knobs for tuning Credit processing:
============================================
ip_api_data_credit_target = 32
ip_api_data_credit_ratio = 80
ip_api_credit_time = 15
ip_api_cwnd_overcommit = 29760
FC control traffic TCP connection:
Local 10.10.9.100:4099, Remote 10.62.0.100:3225
Data transfer TCP connection:
Local 10.10.9.100:4100, Remote 10.62.0.100:3226
IKE Policy 1
IPSec Policy 1
Pre-Shared Key testingFIPSandIPSec
To display QoS Mappings:
switch:admin> portshow fciptunnel 9/ge0 0 -qosmap
Slot: 9 Port: ge0
-------------------------------------------
Tunnel ID 0
Tunnel Description "This is a test Description of this tunnel"
Remote IP Addr 10.62.0.100
Local IP Addr 10.10.9.100
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:39:d4:5a
Compression on
Fastwrite on
Tape Pipelining on
Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps)
SACK on
Min Retransmit Time 100
Keepalive Timeout 90
Max Retransmissions 9
VC QoS Mapping off
DSCP Marking (Control): 10, DSCP Marking (Data): 62
VLAN Tagging Id 1062, L2CoS (Control): 1, L2CoS (data): 0
Connected Count: 1
Uptime 2 hours, 14 minutes, 47 seconds
IKE Policy 1
IPSec Policy 1
Pre-Shared Key testingFIPSandIPSec
VC QoS Map:
VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS
0 46 7 1 07 0 2 11 3 3 15 3
4 19 3 5 23 3 6 27 0 7 31 0
8 35 0 9 39 0 10 43 4 11 47 4
12 51 4 13 55 4 14 59 4 15 63 0