Brocade Web Tools Administrator's Guide (53-1000606-01, October 2007)

36 Web Tools Administrator’s Guide
53-1000606-01
Rebooting the switch
3
Rebooting the switch
When you reboot the switch, the reboot takes effect immediately. Ensure that there is no traffic or
other management on the switch, as traffic is interrupted during the reboot; however, frames are
not dropped. Be sure to save your changes before the reboot, as any changes that were not saved
are lost.
Performing a fast boot
A fast boot reduces boot time significantly by bypassing the power-on self test (POST).
1. Open the Switch Administration window as described on page 29.
2. Click the Fastboot button.
3. On the Fastboot Confirmation window, click Yes to continue.
4. Click Apply.
Performing a reboot
Use the following procedure to reboot the CP and execute the normal power-on booting sequence.
1. Open the Switch Administration window as described on page 29.
2. Click the Reboot button.
3. On the Reboot Confirmation window, click Yes to continue.
4. Click Apply.
Changing system configuration parameters
You must disable the switch before you can configure fabric parameters.
You can change the following system configuration parameters:
Switch fabric settings
Virtual channel settings
Arbitrated loop parameters
System services
Signed firmware
Configuring fabric settings
1. Open the Switch Administration window as described on page 29.
2. Disable the switch as described in “Enabling and disabling a switch” on page 34.
3. Click the Configure tab.
4. Click the Fabric subtab.