Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
50 Fabric OS Message Reference
53-1001157-01
BL-1003
5
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
Additional blade fault messages precede and follow this error, providing more information. See
other error messages for recommended action.
If the message persists, replace the blade.
Severity CRITICAL
BL-1003
Message <timestamp>, [BL-1003], <sequence-number>, FFDC, CRITICAL, <system-name>,
Faulting blade in slot
<slot number>.
Probable Cause Indicates a faulty blade in the specified slot number.
Recommended
Action
Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle
the blade.
Run the systemVerification command to verify that blade does not have hardware problems. Run
the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS
Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1004
Message <timestamp>, [BL-1004], <sequence-number>, FFDC, CRITICAL, <system-name>,
Suppressing blade fault in slot
<slot number>.
Probable Cause Indicates that the specified blade experienced a failure but was not faulted due to a user setting.
Recommended
Action
Reboot or power cycle the blade, using the slotPowerOff and slotPowerOn commands.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1006
Message <timestamp>, [BL-1006], <sequence-number>,, INFO, <system-name>, Blade <slot
number> NOT faulted. Peer blade <slot number> experienced abrupt failure.