Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)
452 Fabric OS Message Reference
53-1000600-02
TRCK-1005
74
Probable Cause Indicates that the track change feature recorded a configuration change for the switch. The track
change feature records any change to the configuration file in nonvolatile memory, including a
configDownload. This message is not generated for a configUpload. All configuration changes occur
through the PDM server, so the PDMIPC is the only task possible.
Recommended
Action
No action is required. Run the configShow command to view the configuration file.
Severity INFO
TRCK-1005
Message <timestamp>, [TRCK-1005], <sequence-number>,, INFO, <system-name>, Track-changes
on
Probable Cause Indicates that the track change feature has been enabled.
Recommended
Action
No action is required. Run the trackChangesSet 0 command to disable the track change feature.
Severity INFO
TRCK-1006
Message <timestamp>, [TRCK-1006], <sequence-number>,, INFO, <system-name>, Track-changes
off
Probable Cause Indicates that the track change feature has been disabled.
Recommended
Action
No action is required. Run the trackChangesSet 1 command to enable the track changes feature.
Severity INFO