Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)
274 Fabric OS Message Reference
53-1000600-02
HIL-1301
33
HIL-1301
Message <timestamp>, [HIL-1301], <sequence-number>,, WARNING, <system-name>, 1 blower
failed or missing. Replace failed or missing blower assembly immediately.
Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is
often preceded by a low speed error message. This problem can cause the switch to overheat.
Recommended
Action
Replace the affected fan FRU immediately.
Severity WARNING
HIL-1302
Message <timestamp>, [HIL-1302], <sequence-number>,, WARNING, <system-name>, <count>
blowers failed or missing. Replace failed or missing blower assemblies
immediately.
Probable Cause Indicates that multiple fan field-replaceable unit (FRU)s have failed or are missing on a switch. This
message is often preceded by a low fan speed message.
Recommended
Action
Replace the affected fan FRUs immediately.
Severity WARNING
HIL-1303
Message <timestamp>, [HIL-1303], <sequence-number>,, ERROR, <system-name>, One fan
failed. Replace failed fan FRU immediately.
Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed. This message is often preceded by a low
fan speed message.
Recommended
Action
Replace the faulty fan FRU immediately
Severity ERROR
HIL-1304
Message <timestamp>, [HIL-1304], <sequence-number>,, ERROR, <system-name>, Two fans
failed. Replace failed fan FRUs immediately.
Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often
preceded by a low fan speed message.
Recommended
Action
Replace the faulty fan FRUs immediately.