Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 87
53-1000600-02
EM-1045
12
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the
associated logical switch is shut down.
Recommended
Action
Run the switchStart command on the associated logical switch.
Severity WARNING
EM-1045
Message <timestamp>, [EM-1045], <sequence-number>,, WARNING, <system-name>, <FRU Id> is
being powered <new state>.
Probable Cause Indicates that an automatic power adjustment is being made because of the (predicted) failure of a
power supply or the insertion or removal of a port blade. If new_state is On, a port blade is being
powered on because more power is available (either a power supply was inserted or a port blade
was removed or powered down). If new_state is Off, a port blade has been powered down because
a power supply has been faulted, because it is indicating a predicted failure. If new_state is Down
(not enough power), a newly inserted port blade was not powered on because there was not
enough power available.
Recommended
Action
The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you
should always operate the system with at least two power supplies for redundancy.
Severity WARNING
EM-1046
Message <timestamp>, [EM-1046], <sequence-number>,, WARNING, <system-name>, Sysctrl
reports error status for blade ID <id value> for the blade in slot <slot number>
<UNKNOWN VALUE>
Probable Cause Indicates that the system controller encountered a blade with an unknown ID in the slot specified.
Recommended
Action
If the blade ID listed is not correct, then the field-replaceable unit (FRU) header for the blade is
corrupted and the blade must be replaced.
For the Brocade 24000, the blade ID should be 5 for a control processor (CP) blade and 4 for a port
blade.
Severity WARNING
EM-1047
Message <timestamp>, [EM-1047], <sequence-number>,, INFO, <system-name>, CP in slot <slot
number>
not faulty, CP ERROR deasserted.
Probable Cause Indicates that the control processor (CP) is no longer faulted. This message usually follows
EM-1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal.