User Manual

Fabric OS 5.0.0 procedures user guide 103
Example:
3. Issue the urouteshow command to display unicast routing information.
For the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, and SAN
Switch 4/32, use the following syntax:
urouteshow [portnumber][, domainnumber]
For the Core Switch 2/64 and the SAN Director 2/128, use the following syntax:
urouteshow [slot/][portnumber][, domainnumber]
The following entries appear:
switch:admin> topologyshow
2 domains in the fabric; Local Domain ID: 1
Domain: 6
Metric: 500
Name: switch
Path Count: 4
Hops: 1
Out Port: 60
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 61
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 62
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 58
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Local Domain Domain number of local switch
In Ports Port from which a frame is received
Domain Destination domain of incoming frame
Out Port The port that incoming frame is forwarded to, in order to reach
the destination domain
Metric Cost of reaching destination domain
Hops The maximum number of hops to reach destination domain
Flags Indicates whether route is dynamic (D) or static (S). A static
route is assigned using the command urouteconfig
Next (Dom, Port) Domain and port number of the next hop. These are the
domain number and the port