Home Security System User Manual
– 6 –
*39 ENABLE OPEN/CLOSE REPORT FOR [0]
INSTALLER CODE 1=enable; 0=disable
*40 OPEN/CLOSE REPORT FOR KEYSWITCH [0]
1=enable; 0=disable
*41 NORMALLY CLOSED or EOLR (Zones 2-8) [1]
1=N.C.loops; 0=EOLR supervision.
Must be "0" for UL installations.
*42 DIAL TONE PAUSE [0]
0=5 seconds; 1=11 seconds; 2=30 seconds.
Must be "0" UL Installations.
*43 DIAL TONE DETECTION [1]
1=wait for true dial tone; 0=pause, then dial
*44 RING DETECTION COUNT [00] |
01-14; 15=answering machine; 00=no detection.
Must be "00" for UL Burglary.
*45 PRIMARY FORMAT [1]
0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed;
3= ADEMCO Express
*46 LOW SPEED FORMAT (Primary) [0]
0= ADEMCO Low Speed; 1=Sescoa/Radionics
*47 SECONDARY FORMAT [1]
0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed;
3= ADEMCO Express
*48 LOW SPEED FORMAT (Sec.) [0]
0= ADEMCO Low Speed; 1=Sescoa/Radionics
*49 CHECKSUM VERIFICATION [0] [0]
1=yes; 0=no Prim Sec
*50 SESCOA/RADIONICS SELECT [0]
1=Sescoa; 0=Radionics
*51 DUAL REPORTING [0]
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms and alarm restores go to both primary & secondary
numbers, while all other reports go to secondary only. If used
with Split Reporting "2" option, alarms and alarm restores go to
both, open/close and test messages go to secondary only,
while all other reports go to primary.
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
[0 0 0 0 0 0]
Alarm
Rstr
Byp
Trbl
O/C
LoBat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0 0 0 0 0 0]
Alarm
Rstr
Byp
Trbl
O/C
LoBat
0=standard; 1=expanded;
*54 *57 ALARM REPORT CODES & ID DIGITS FOR
ZONES 01-16.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*58
SUPERVISORY AND RESTORE CODES FOR ZONES
01-16.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
|
Alarm Rst
|
Trbl
|
Trbl Rst
|
Byp
|
Byp Rst
*59 *62 ALARM REPORT CODES & ID DIGITS FOR
ZONES 17-32.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*63 SUPERVISORY AND RESTORE CODES FOR ZONES
17-32.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
|
Alarm Rst
|
Trbl
|
Trbl Rst
|
Byp
|
Byp Rst
*64 *67 ALARM REPORT CODES & ID DIGITS FOR
ZONES 33-48.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*68 SUPERVISORY AND RESTORE CODES FOR ZONES
33-48.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
|
Alarm Rst
|
Trbl
|
Trbl Rst
|
Byp
|
Byp Rst
*69 *72 ALARM REPORT CODES & ID DIGITS FOR
ZONES 49-64.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*73 SUPERVISORY AND RESTORE CODES FOR ZONES
49-64.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
|
Alarm Rst
|
Trbl
|
Trbl Rst
|
Byp
|
Byp Rst
*74 *77 ALARM REPORT CODES & ID DIGITS FOR
ZONES 81-99.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*78 SUPERVISORY AND RESTORE CODES FOR ZONES
81-99.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
|
Alarm Rst
|
Trbl
|
Trbl Rst
|
Byp
|
Byp Rst
ZONE TYPE RESTORE ENABLES
*79 FOR ZONE TYPES 1-8
1
2
3
4
5
6
7
8
1=enable; [0=disable]
*80 FOR TYPES 9, and 10
9 10
1=enable; [0=disable]