Product Overview

PRODUCT DATA
66-2039-02
V5097A-E
Industrial Gas Valves
APPLICATION
The V5097A-E Gas Valves are used with the V4055, V4062
and V9055 Fluid Power Actuators to control gas flow to
commercial and industrial burners.
NOTICE: Per Industry Standards, the actuator is required a
conduit seal or a cable type that is sealed be installed in a
device that can result in a flammable liquid flow through a
conduit or cable to an electrical ignition source in the event of
a seal leakage or diaphragm failure.
FEATURES
Used with natural or liquefied petroleum (LP) gases.
V5097 normally closed valves are rated for final shutoff
service (safety shutoff).
V5097A,C,D,E Valves are for On-Off service.
V5097B Valve has a characterized guide and in
combination with the V4055, V4062 and V9055 Fluid
Power Actuators, provides slow-opening, HI-LO-OFF, and
modulating functions, respectively.
•V
5097C,E Valves have a double seal and are used
with V4055D,E Fluid Power Actuators to provide
proof-of-closure switch and valve seal overtravel
interlock.
V5097D,E Valves are for high pressure applications (see
Table 1).
Two valve body types (small and large) applicable to seven
pipe sizes:
Small body type for 3/4 in. (19 mm), 1 in. (25 mm), 1-1/
4 in. (32 mm), 1-1/2 in. (38 mm) and 2 in. (51 mm)
pipes.
Large body type for 2 in., 2-1/2 in. and 3 in. pipes.
Seven pipe adapter sizes (3/4 in. to 3 in.) have NPT or
BSP-PL threaded connections.
V5097 version provides three 1/4 in. upstream and two 1/4
in. downstream taps and plugs. European Community
(CE) version provides an additional downstream tap and
plug.
Valve body rating of 75 psi (517.1 kPa); body passes
Underwriters Laboratories Inc. burst test.
Yellow SHUT indicator attached to valve stem indicates
valve closed position.
Unpainted die-cast aluminum body.
SPECIFICATIONS
IMPORTANT:
The specifications given in this publication do not
include normal manufacturing tolerances; therefore,
an individual unit may not exactly match the listed
specifications. Also, this product is tested and cali-
brated under closely controlled conditions, and some
minor differences in performance can be expected if
those conditions are changed.
Models (See Table 1):
Type of Gas: Natural or liquefied petroleum (LP) only.
Pipe Size: 3/4 in., 1 in., 1-1/4 in., 1-1/2 in., 2 in., 2-1/2 in., 3 in.
Pipe Threads: NPT or BSP-PL threads (equivalent to ISO R7
and DIN 2999). 3/4 in. to 3 in. pipe adapters available.
Pressure Ratings: See Table 2.

Summary of content (4 pages)