Temperature Ranges
• Heat:40°to90°F(4.5°to32°C)
• Cool:50°to99°F(10°to37°C)
Operating Ambient Temperature
• 0°to120°F(-18°to48.9°C)
Shipping Temperature
• -30°to150°F(-34°to66°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Physical Dimensions
• 4-9/16”Hx6”Wx1-3/8”D
• 116mmHx152mmWx35mmD
Electrical Ratings
Terminal Voltage(50/60Hz) RunningCurrent
WHeating 20-30Vac 0.02-1.0A
(Powerpile) 750mVDC 100mADC
W2Heating 20-30Vac 0.02-0.6A
YCooling 20-30Vac 0.02-1.0A
Y2Cooling 20-30Vac 0.02-0.6A
Aux/EAux.heat 20-30Vac 0.02-1.0A
Emergencyheat
O/BChangeover 20-30Vac 0.02-0.6A
LHeatpumpreset 20-30Vac 0.02-0.6A