63-2652.fm Page 2 Wednesday, February 7, 2007 9:21 AM FEATURES • Intelligent Fan™ feature energizes fan continuously in the Occupied periods. Fan can also be configured for conventional heat or electric heat fan operation. • Remote sensor capability for temperature (including outdoor air and discharge air) and humidity sensors. • Recovery ramping control automatically optimizes equipment start times based on building load. • Universal Versaguard™ Thermostat guards available.
63-2652.fm Page 3 Wednesday, February 7, 2007 9:21 AM SETTINGS Using Thermostat Keys NOTE: See Fig. 1 for keypad information. The thermostat keys are used to: • set current time and day, • program times and setpoints for heating and cooling, • override the program temperatures, • display present setting, • set system and fan operation, • perform simple configuration. Setting Temperature Refer to Table 1 for default temperature setpoints.
63-2652.fm Page 4 Wednesday, February 7, 2007 9:21 AM Setting System and Fan Fan Settings — On: Fan operates continuously in occupied and standby periods. Fan cycles with call for heat or cool during not occupied periods. — Auto: Fan cycles with call for heating or cooling during occupied, standby, and not occupied periods. System default setting is Auto.
63-2652.fm Page 5 Wednesday, February 7, 2007 9:21 AM IMPORTANT Programming the thermostat with the keypad requires 24 Vac (turn on system power). The keyboard lockout feature must be disabled. The thermostat can be set for two Occupied and two Not Occupied times for each day of the week (28 independent time settings). The Temporary Occupied key provides quick setpoint changes for increased comfort during Not Occupied periods.
3-2652.fm Page 6 Wednesday, February 7, 2007 9:21 AM Table 2. Occupied and Not Occupied Period Start Times. Day Occupied Period 1 Not Occupied Period 1 Occupied Period 2 Not Occupied Period 2 Monday Tuesday Wednesday Thursday Friday Saturday Sunday NOTE: 12:00 PM is Noon, and 12:00 AM is Midnight.
63-2652.fm Page 7 Wednesday, February 7, 2007 9:21 AM Set Day/Time Temperature Occupied HEAT Not Occupied COOL HEAT COOL Day Time System Fan Run Copy HEAT COOL ON AUTO Schedule Schedule Day Clear Occupied Not Occupied Start Time Override Temporary Temporary Occupied Not Occupied M19610BB Fig. 1. Thermostat key locations. When using the keypad to change the day/time: 1. Press Set Day until the current day is displayed. Fri = Friday, Sat = Saturday. 2. 3.
63-2652.fm Page 8 Wednesday, February 7, 2007 9:21 AM 4. Copying a Day Press Run Schedule. Use the keys in the “Schedule” area of the keypad for this procedure. Setting Schedule Times Use the keys in the “Schedule” area of the keypad for this procedure. 1. NOTE: The thermostat must be in program mode to use the copy feature. If the thermostat is already in program mode, skip step 1. Press Occupied. NOTE: Anytime a start time is not required, press Clear Start Time. 2. 3. 4. 5. 6. 1. Press Occupied.
63-2652.fm Page 9 Wednesday, February 7, 2007 9:21 AM 7. 8. Temperature Setpoints Repeat steps 2 through 6 for all the days desired. Press Run Schedule. Setpoint Limits The setpoint temperature range is 40 to 90 °F (4 to 32 °C) for heating and 45 to 99 °F (7 to 37 °C) for cooling. Clearing Program Start Times 1. 2. 3. 4. 5. Press Occupied or Not Occupied until the start period to be cleared is displayed. Press Day until desired day is displayed. Press Clear Start Time.
63-2652.fm Page 10 Wednesday, February 7, 2007 9:21 AM 6. 7. 8. 9. T7770 Setpoint Knob Press up ! or down " until the desired temperature is displayed. Press Not Occupied Cool. Press up ! or down " until the desired temperature is displayed. Press Run Schedule. A T7770 setpoint knob can remotely adjust the T7350 setpoint. This adjustment can be made when the sensor is in override. NOTES: — Temperature Setpoint Overrides — IMPORTANT — Setup determines Occupied override duration.
63-2652.fm Page 11 Wednesday, February 7, 2007 9:21 AM 1. 2. NOTES: — To use the default occupied override, press Temporary Occupied. NOTE: The default temperature setting is the Occupied setpoint. — To select a temperature setting other than the default, press up ! or down " until desired temperature offset displays (range is configurable by the installer from 0 to 5 °F (0 to 3 °C)). — 1. 2.
63-2652.fm Page 12 Wednesday, February 7, 2007 9:21 AM NOTE: The only way to change this setpoint is to change the Not Occupied setpoint. Changing Temperature Setpoint Until Next Program Period 1. 2. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2007 Honeywell International Inc. 63-2652 J.I.