Captuvo Enterprise Sled Series User’s Guide ™
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Table of Contents Chapter 1 - Getting Started Introduction ................................................................. 1-1 Out of the Box ............................................................. 1-1 Operating Temperature ............................................... 1-1 Reading Techniques ................................................... 1-2 Setting Custom Defaults ............................................. 1-2 Resetting the Custom Defaults ...................................
Chapter 3 - Data Editing Prefix/Suffix Overview..................................................3-1 To Add a Prefix or Suffix: ....................................... 3-1 To Clear One or All Prefixes or Suffixes ................ 3-2 To Add a Carriage Return Suffix to All Symbologies33 Prefix Selections ..........................................................3-3 Suffix Selections ..........................................................3-4 Function Code Transmit ..........................................
Code 93..................................................................... 5-14 Code 93 Code Page............................................ 5-14 Straight 2 of 5 Industrial (three-bar start/stop) .......... 5-15 Straight 2 of 5 IATA (two-bar start/stop).................... 5-16 Matrix 2 of 5 .............................................................. 5-17 Code 11..................................................................... 5-18 Code 128..........................................................
Aztec Code ................................................................5-52 Aztec Code Page ................................................. 5-53 Chinese Sensible (Han Xin) Code .............................5-54 Postal Codes - 2D......................................................5-55 Single 2D Postal Codes: ...................................... 5-55 Combination 2D Postal Codes:............................ 5-56 Postal Codes - Linear ................................................
ISO 2022/ISO 646 Character Replacements ............
vi
1 Getting Started Introduction The Captuvo Enterprise Sleds include an optional integrated imager for scanning all types of bar codes. You have the capability to configure the scan engine in the sled using the programming bar codes included in this user’s guide; however, the application being used might override the settings you have programmed. An optional magnetic stripe reader (MSR) for reading cards with magnetic stripes is also available.
Reading Techniques The sled has a view finder that projects a bright red aiming beam that corresponds to the sled’s horizontal field of view. The aiming beam should be centered over the bar code, but it can be positioned in any direction for a good read. Linear bar code 2D Matrix symbol The aiming beam is smaller when the sled is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit.
entire sequence will be saved to your custom defaults. When you have entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code. Set Custom Defaults Save Custom Defaults You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one.
Resetting the Factory Defaults ! This selection erases all your settings and resets the sled to the original factory defaults. It also disables all plugins. If you aren’t sure what programming options are in your sled, or you’ve changed some options and want to restore the sled to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults. This resets the sled to the factory default settings.
2 Input/Output Settings Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper Good Read On. Beeper - Good Read Off * Beeper - Good Read On Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the sled emits on a good read. Default = High.
Manual Trigger Mode When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. Normal mode offers good scan speed and the longest working ranges (depth of field). Default = Manual Trigger-Normal. Manual Trigger - Normal Mobile Phone Read Mode When this mode is selected, your sled is optimized to read bar codes from mobile phone or other LED displays. However, the speed of scanning printed bar codes may be slightly lower when this mode is enabled.
In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read. 0% Bar Code 1 10 Bar Code 2 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100% Note: A bar code needs only to be touched by the centering window in order to be read.
* Centering Off Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window Preferred Symbology The sled can be programmed to specify one symbology as a higher priority over other symbologies in situations where both bar code symbologies appear on the same label, but the lower priority symbology cannot be disabled. For example, you may be using the sled in a retail setting to read U.P.C. symbols, but have occasional need to read a code on a drivers license.
Scan a bar code below to enable or disable Preferred Symbology. Preferred Symbology Off. Default = Preferred Symbology On * Preferred Symbology Off High Priority Symbology To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Charts on page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). Scan Save to save your selection.
code has been encountered. Scan the bar code below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 500 ms. Preferred Symbology Time-out Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default values. Preferred Symbology Default Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the sled decodes it.
To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Require Output Sequence, page 2-10). 2. Code I.D. On the Symbology Charts on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover). 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart.
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the sled to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example.
SEQBLKsequence editor start command 62 code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 0012 C - Code 93 sample length (11) plus CR suffix (1) = 12 43 start character match for
Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the sled will not transmit the output data to the host device. When it’s On/Not Required, the sled will attempt to get the output data to conform to an edited sequence but, if it cannot, the sled transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the sled decodes it. Default = Off.
No Read With No Read turned On, the sled notifies you if a code cannot be read. If using an EZConfig Tool Scan Data Window (see page 9-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off. On * Off If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data Formatting beginning on page 4-1). The hex code for the No Read symbol is 9C.
Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright: Vertical, Top to Bottom: (Rotate CW 90°) Upside Down: Vertical, Bottom to Top: (Rotate CCW 90°) Default = Upright.
3 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data.
symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252), beginning on page A-4, for the prefix or suffix you wish to enter. Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual. Step 6.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Charts, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Your change is automatically saved.
Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the sled transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 8-2. Default = Enable.
4 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the sled’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None. Normally, when you scan a bar code, it is outputted automatically.
you are programming. (See Primary/Alternate Data Formats on page 4-17 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 4-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: 099 indicates all terminal types. Step 4. Code I.D.
Discard Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing. Scan the Terminal Type and Code I.D. (see Symbology Charts on page A-1), and the bar code data length for the specific data format that you want to delete. All other formats remain unaffected.
Terminal ID Table Terminal Serial Model(s) RS232 Terminal ID 000 Data Format Editor Commands When working with the Data Format Editor, a virtual cursor is moved along your input data string. The following commands are used to both move this cursor to different positions, and to select, replace, and insert data into the final output. For examples that use the Data Format Editor commands, refer to Data Formatter on page 4-15.
Send the first 10 characters from the bar code above, followed by a carriage return, followed by the rest of the characters.
B9 Example: Send all characters up to a defined string Using the bar code above, send all characters up to but not including “AB.” Command string: B900024142 B9 is the “Send all characters up to a string” command 0002 is the length of the string (2 characters) 41 is the hex value for A 42 is the hex value for B The data is output as: 1234567890 Send all but the last characters E9 Include in the output message all but the last “nn” characters, starting from the current cursor position.
Insert a string BA Send “ss” string of “nn” length in the output message, leaving the cursor in the current position. Syntax = BAnnnns...s where nnnn stands for the length of the string, and s...s stands for the string. The string is made up of hex values for the characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-4 for decimal, hex and character codes.
B3 and B4 Example: Insert the symbology name and length Send the symbology name and length before the bar code data from the bar code above. Break up these insertions with spaces. End with a carriage return.
Move the cursor backward a number of characters F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn where nn is the numeric value (00-99) for the number of characters the cursor should be moved back. Move the cursor to the beginning F7 Move the cursor to the first character in the input message. Syntax = F7. FE and F7 Example: Manipulate bar codes that begin with a 1 Search for bar codes that begin with a 1.
Search for the letter “D” in bar codes and send all the data that follows, including the “D.” Using the bar code above: Command string: F844F10D F8 is the “Search forward for a character” command 44 is the hex value for “D” F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: DEFGHIJ Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character.
Search backward for a string B1 Search backward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B1nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B1000454657374 will search backward for the first occurrence of the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), page A-4 for decimal, hex and character codes.
Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number of suppressed characters in the list, and xxyy .. zz is the list of characters to be suppressed.
If the bar code has characters that the host application does not want included, you can use the E4 command to replace those characters with something else. In this example, you will replace the zeroes in the bar code above with carriage returns.
EC is the “Check for a number” command F1 is the “Send all characters” command 0D is the hex value for a CR If this bar code is read, the format fails. If this bar code is read: the data is output as: 1234AB Check for non-numeric character ED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborted if the character is not numeric.
Other data format settings impact the B8 command. If Data Format Non-Match Error Tone is On (page 4-16), the scanner emits an error tone. If Data format Non-Match Error Tone is Off, the code is disabled for reading and no tone is sounded. Data Formatter When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes. Data Formatter Off You may wish to require the data to conform to a data format you have created and saved.
Choose one of the following options. Default = Data Formatter On, Not Required, Keep Prefix/Suffix. * Data Formatter On, Not Required, Keep Prefix/Suffix Data Formatter On, Not Required, Drop Prefix/Suffix Data Format Required, Keep Prefix/Suffix Data Format Required, Drop Prefix/Suffix Data Format Non-Match Error Tone When a bar code is encountered that doesn’t match your required data format, the sled normally generates an error tone.
Primary/Alternate Data Formats You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the bar codes below. Primary Data Format Data Format 1 Data Format 2 Data Format 3 Single Scan Data Format Change You can also switch between data formats for a single scan.
For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned uses Data Format 1, then reverts back to Data Format 3.
5 Symbologies This programming section contains the following menu selections. Refer to Chapter 6 for settings and defaults.
All Symbologies If you want to decode all the symbologies allowable for your sled, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology. All Symbologies On All Symbologies Off Note: When All Symbologies On is scanned, 2D Postal Codes are not enabled. 2D Postal Codes must be enabled separately.
Codabar Codabar On/Off * On Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can program the sled to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character.
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the sled looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character.
Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Off Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character No Check Character indicates that the sled reads and transmits bar code data with or without a check character.
When Check Character is set to Validate and Transmit, the sled only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character. * No Check Character Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 0-48.
codes are read, deleting the first space from each. The sled transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off. On * Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Note: Trioptic Code (page 5-40) must be turned off while scanning Code 32 Pharmaceutical codes.
Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
10), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the sled reads and transmits bar code data with or without a check digit.
When Check Digit is set to Validate and Transmit, the sled only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 2-80.
NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the sled reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Off Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Code Page Code pages define the mapping of character codes to characters.
10), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 93 Code Page Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off On * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information.
Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA On/Off On * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Matrix 2 of 5 Matrix 2 of 5 On/Off On * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Code 11 Code 11 On/Off On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits.
Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. On * Off Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 0-90. Minimum Default = 0, Maximum Default = 90.
Code 128 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
GS1-128 GS1-128 On/Off * On Off GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80.
Telepen Telepen On/Off On * Off Telepen Output Using AIM Telepen Output, the sled reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the sled reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length UPC-A UPC-A On/Off * On Off Note: To convert UPC-A bar codes to EAN-13, see Convert UPC-A to EAN13 on page 5-31.
UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On Off UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
UPC-A Addenda Required When Required is scanned, the sled will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 5-25. Default = Not Required. Required * Not Required UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.
Default = Off. * Off Allow Concatenation Require Concatenation UPC-E0 UPC-E0 On/Off Most U.P.C. bar codes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 5-30). Default = On.
UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. On * Off UPC-E0 Addenda Required When Required is scanned, the sled will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On.
UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off UPC-E0 Leading Zero This feature allows the transmission of a leading zero (0) at the beginning of scanned data. To prevent transmission, scan Off. Default = On. * On Off UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda.
UPC-E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 5-27). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off.
EAN/JAN-13 EAN/JAN-13 On/Off * On Off Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A.
EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN-13 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Off Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 5-26). ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off.
EAN/JAN-8 EAN/JAN-8 On/Off * On Off EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the sled will only read EAN/JAN-8 bar codes that have addenda. Default = Not Required.
MSI MSI On/Off On * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the sled to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the sled will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data.
GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On Off GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On Off 5 - 38
GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 5-8), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media.
Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600.
Codablock F Codablock F On/Off On * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
PDF417 < Default All PDF417 Settings > PDF417 On/Off * On Off PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off On * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. On * Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.
GS1 Emulation The sled can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize one data carrier type.) If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.
TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. Default = Off. On * Off QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR Code.
QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089.
Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Off Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
mined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = On. * On Off Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off On * Off MaxiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Off Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
ter(s), it buffers the number of Aztec bar codes determined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = On. * On Off Aztec Code Page Aztec Code pages define the mapping of character codes to characters.
Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off On * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833.
Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off.
Postnet On Also see Postnet Check Digit, page 5-58.
Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet, Postal-4i, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Postnet with B and B’ Fields On Planet Code, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Planet Code, Postal-4i
Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postal Codes - Linear The following lists linear postal codes.
China Post (Hong Kong 2 of 5) On/Off On * Off China Post (Hong Kong 2 of 5) Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Korea Post Korea Post On * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 5-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
6 Serial Programming Commands Note: This section is for developers’ reference only. The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the sled. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an RS232 interface (see page 2-1).
Query Commands Several special characters can be used to query the device about its settings. ^ ? * What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.) :Name: Field Usage (Optional) This command returns the query information from the sled.
NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command.
the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Resetting the Custom Defaults If you want the custom default settings restored to your sled, scan the Activate Custom Defaults bar code below. This resets the sled to the custom default settings. If there are no custom defaults, it will reset the sled to the factory default settings.
Menu Commands Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Product Default Settings Setting Custom Defaults Set Custom Defaults MNUCDF 1-3 Save Custom Defaults MNUCDS 1-3 Resetting the Custom Defaults Activate Custom Defaults DEFALT 1-3 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 1-4 Activate Defaults DEFALT 1-4 BEPBEP0 2-1 Input/Output Selections Beeper - Good Read Off *On BEPBEP1 2-1 Beeper Volume Good Read Off BEPLVL0
Selection Preferred Symbology Setting * Indicates default Serial Command # Indicates a numeric entry Page On PRFENA1 2-5 *Off PRFENA0 2-5 High Priority Symbology PRFCOD## 2-5 Low Priority Symbology PRFBLK## 2-5 Preferred Symbology Timeout (*500) Range 1003000 PRFPTO#### 2-6 Preferred Symbology Default PRFDFT 2-6 Output Sequence Editor Enter Sequence SEQBLK 2-9 Default Sequence SEQDFT 2-9 Partial Sequence Transmit Partial Sequence SEQTTS1 2-9 *Discard Partial Sequence SEQTTS
Selection Prefix Suffix Function Code Transmit Setting Serial Command * Indicates default # Indicates a numeric entry Page Add Prefix PREBK2## 3-3 Clear One Prefix PRECL2 3-3 Clear All Prefixes PRECA2 3-3 Add Suffix SUFBK2## 3-4 Clear One Suffix SUFCL2 3-4 Clear All Suffixes SUFCA2 3-4 *Enable RMVFNC0 3-4 Disable RMVFNC1 3-4 DFMDF3 4-1 Enter Data Format DFMBK3## 4-2 Clear One Data Format DFMCL3 4-3 Clear All Data Formats DFMCA3 4-3 Data Formatter Selections Data Fo
Selection Primary/Alternate Data Formats Single Scan Data Format Change Setting Serial Command # Indicates a numeric entry Page Primary Data Format ALTFNM0 4-17 Data Format 1 ALTFNM1 4-17 Data Format 2 ALTFNM2 4-17 Data Format 3 ALTFNM3 4-17 Single Scan-Primary Data Format VSAF_0 4-18 Single Scan-Data Format 1 VSAF_1 4-18 Single Scan-Data Format 2 VSAF_2 4-18 Single Scan-Data Format 3 VSAF_3 4-18 All Symbologies Off ALLENA0 5-2 All Symbologies On ALLENA1 5-2 Default All Co
Selection Code 39 Setting Serial Command # Indicates a numeric entry Page Default All Code 39 Settings C39DFT 5-6 Off C39ENA0 5-6 * Indicates default *On C39ENA1 5-6 Code 39 Start/Stop Char. *Don’t Transmit C39SSX0 5-6 Transmit C39SSX1 5-6 Code 39 Check Char. *No Check Char.
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Interleaved 2 of 5 Message Length Minimum (2 - 80) *4 I25MIN## 5-11 Maximum (2 - 80) *80 I25MAX## 5-11 NEC 2 of 5 Default All NEC 2 of 5 Settings N25DFT 5-12 Off N25ENA0 5-12 *On N25ENA1 5-12 NEC 2 of 5 Check Digit *No Check Char.
Selection Straight 2 of 5 IATA Setting Serial Command # Indicates a numeric entry Page *Off A25ENA0 5-16 On A25ENA1 5-16 * Indicates default Straight 2 of 5 IATA Message Length Minimum (1 - 48) *4 A25MIN## 5-16 Maximum (1 - 48) *48 A25MAX## 5-16 Matrix 2 of 5 Default All Matrix 2 of 5 Settings X25DFT 5-17 *Off X25ENA0 5-17 On X25ENA1 5-17 Matrix 2 of 5 Message Length Minimum (1 - 80) *4 X25MIN## 5-17 Maximum (1 - 80) *80 X25MAX## 5-17 Code 11 Default All Code 11 Settings
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Code 128 Code Page Code 128 Code Page (*2) 128DCP## 5-21 GS1-128 Default All GS1-128 Settings GS1DFT 5-22 *On GS1ENA1 5-22 Off GS1ENA0 5-22 GS1-128 Message Length Minimum (1 - 80) *1 GS1MIN 5-22 Maximum (0 - 80) *80 GS1MAX 5-22 Telepen Default All Telepen Settings TELDFT 5-23 *Off TELENA0 5-23 On TELENA1 5-23 *AIM Telepen Output TELOLD0 5-23 Original Telepen Output TELOLD1 5-23 Tele
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page UPC-A Addenda Separator Off UPAADS0 5-26 *On UPAADS1 5-26 UPC-A/EAN-13 with Extended Coupon Code *Off CPNENA0 5-27 Allow Concatenation CPNENA1 5-27 Require Concatenation CPNENA2 5-27 UPC-E0 Default All UPC-E Settings UPEDFT 5-27 Off UPEEN00 5-27 *On UPEEN01 5-27 UPC-E0 Expand *Off UPEEXP0 5-28 On UPEEXP1 5-28 UPC-E0 Addenda Required Required UPEARQ1 5-28 *Not Required UPEARQ0 5-2
Selection Setting Serial Command * Indicates default # Indicates a numeric entry Page 2 Digit Addenda On E13AD21 5-32 *2 Digit Addenda Off E13AD20 5-32 5 Digit Addenda On E13AD51 5-32 *5 Digit Addenda Off E13AD50 5-32 EAN/JAN-13 Addenda Required *Not Required E13ARQ0 5-32 Required E13ARQ1 5-32 EAN/JAN-13 Addenda Separator Off E13ADS0 5-33 *On E13ADS1 5-33 EAN/JAN-13 2 Digit Addenda ISBN Translate EAN/JAN-8 *Off E13ISB0 5-33 On E13ISB1 5-33 Default All EAN/ JAN 8 Setti
Selection MSI Check Character MSI Message Length GS1 DataBar Omnidirectional GS1 DataBar Limited Setting Serial Command # Indicates a numeric entry Page *Validate Type 10, but Don’t Transmit MSICHK0 5-37 Validate Type 10 and Transmit MSICHK1 5-37 Validate 2 Type 10 Chars, but Don’t Transmit MSICHK2 5-37 Validate 2 Type 10 Chars and Transmit MSICHK3 5-37 Validate Type 10 then Type 11 Char, but Don’t Transmit MSICHK4 5-37 Validate Type 10 then Type 11 Char and Transmit MSICHK5 5-37 Di
Selection GS1 DataBar Expanded GS1 DataBar Expanded Msg. Length Trioptic Code Codablock A Codablock A Msg. Length Codablock F Codablock F Msg.
Selection PDF417 Msg. Length MicroPDF417 Setting Serial Command # Indicates a numeric entry Page Minimum (1-2750) *1 PDFMIN 5-43 Maximum (1-2750) *2750 PDFMAX 5-43 Default All Micro PDF417 Settings MPDDFT 5-44 On MPDENA1 5-44 *Off MPDENA0 5-44 * Indicates default MicroPDF417 Msg.
Selection QR Code Msg. Length Data Matrix Data Matrix Msg.
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Aztec Code Page Aztec Code Page (*51) AZTDCP## 5-53 Chinese Sensible (Han Xin) Code Default All Han Xin Code Settings HX_DFT 5-54 On HX_ENA1 5-54 *Off HX_ENA0 5-54 Minimum (1-7833) *1 HX_MIN 5-54 Maximum (1-7833) *7833 HX_MAX 5-54 2D Postal Codes *Off POSTAL0 5-55 Single 2D Postal Codes Australian Post On POSTAL1 5-55 British Post On POSTAL7 5-55 Canadian Post On POSTAL30 5-55 Intellig
Selection Combination 2D Postal Codes 6 - 20 Setting Serial Command # Indicates a numeric entry Page InfoMail and British Post On POSTAL8 5-56 Intelligent Mail Bar Code and Postnet with B and B’ Fields On POSTAL20 5-56 Postnet and Postal4i On POSTAL14 5-56 Postnet and Intelligent Mail Bar Code On POSTAL16 5-56 Postal-4i and Intelligent Mail Bar Code On POSTAL17 5-56 * Indicates default
Selection Combination 2D Postal Codes (continued) Setting Serial Command # Indicates a numeric entry Page Postal-4i and Postnet with B and B’ Fields On POSTAL19 5-56 Planet and Postnet On POSTAL12 5-56 Planet and Postnet with B and B’ Fields On POSTAL18 5-56 Planet and Postal-4i On POSTAL13 5-57 Planet and Intelligent Mail Bar Code On POSTAL15 5-57 Planet, Postnet, and Postal-4i On POSTAL21 5-57 Planet, Postnet, and Intelligent Mail Bar Code On POSTAL22 5-57 Planet, Postal-4i, and I
Selection Setting Serial Command # Indicates a numeric entry Page Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet On POSTAL28 5-57 Planet, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On POSTAL29 5-57 Planet Code Check Digit Transmit PLNCKX1 5-58 *Don’t Transmit PLNCKX0 5-58 Postnet Check Digit Transmit NETCKX1 5-58 *Don’t Transmit NETCKX0 5-58 Default All China Post (Hong Kong 2 of 5) Settings CPCDFT 5-58 *Off CPCENA0 5-59 On CPCENA1 5-59
7 Maintenance Repairs Honeywell is not an authorized Apple repair center. Please return only your sled to us for repair. Honeywell is not liable for any non-Honeywell product shipped to our repair center. Healthcare Housing Cleaning Directions (Healthcare unit only) ! Honeywell is not responsible for any damage to the Apple device. Since the Apple device can be affected by these cleaning agents, be sure to remove it before cleaning the sled.
• The battery has been charged for at least 4 hours. • Make certain that the Honeywell Price Check Simulator application from the Apple App StoreSM is loaded. Is the sled having trouble reading your symbols? If the sled isn’t reading symbols well, check that the symbols: • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. The sled won’t read your bar code at all. 1. Scan the sample bar codes in the back of this manual.
8 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please contact us by using one of the methods below: Knowledge Base: www.hsmknowledgebase.com Our Knowledge Base provides thousands of immediate solutions. If the Knowledge Base cannot help, our Technical Support Portal (see below) provides an easy way to report your problem or ask your question. Technical Support Portal: www.hsmsupportportal.
This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to HII factory or authorized service center for inspection. No product will be accepted by HII without a Return Materials Authorization, which may be obtained by contacting HII.
A Reference Charts Symbology Charts Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 3-1 and Data Formatting beginning on page 4-1 for information about using Code ID and AIM ID.
AIM Honeywell ID Possible modifiers (m) ID Hex GS1 DataBar ]em 0 y 79 GS1 DataBar Limited ]em { 7B GS1 DataBar Expanded ]em } 7D GS1-128 ]C1 I 49 ]X0 Q 51 Symbology GS1 2 of 5 China Post (Hong Kong 2 of 5) Interleaved 2 of 5 ]Im e 65 Matrix 2 of 5 ]X0 m 6D NEC 2 of 5 ]X0 Y 59 Straight 2 of 5 IATA ]Rm 0, 1, 3 f 66 f 66 0, 1 g 67 t 74 Straight 2 of 5 Industrial ]S0 MSI ]Mm Telepen ]Bm UPC 0, 1, 2, 3, 8, 9, A, B, C UPC-A ]E0 c 63 UPC-A with Add-On
2D Symbologies AIM Honeywell ID Possible modifiers (m) ID Hex Aztec Code ]zm 0-9, A-C z 7A Chinese Sensible Code (Han Xin Code) ]X0 H 48 Symbology All Symbologies 99 Codablock A ]O6 0, 1, 4, 5, 6 V 56 Codablock F ]Om 0, 1, 4, 5, 6 q 71 Code 49 ]Tm 0, 1, 2, 4 l 6C Data Matrix ]dm 0-6 w 77 y 79 y 79 GS1 ]em 0-3 GS1 Composite ]em 0-3 GS1 DataBar Omnidirectional ]em MaxiCode ]Um 0-3 x 78 PDF417 ]Lm 0-2 r 72 ]Lm 3-5 R 52 ]Qm 0-6 s 73 s 73 Micro
AIM Symbology ID Possible modifiers (m) Honeywell ID Hex China Post ]X0 Q 51 InfoMail ]X0 , 2c Intelligent Mail Bar Code ]X0 M 4D Japanese Post ]X0 J 4A KIX (Netherlands) Post ]X0 K 4B Korea Post ]X0 ? 3F Planet Code ]X0 L 4C Postal-4i ]X0 N 4E Postnet ]X0 P 50 ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X function is OS and application dependent.
Non-printable Keyboard Control + ASCII (CTRL+X) Mode ASCII control characters Windows Mode Control + X Mode On (KBDCAS2) DEC HEX Char Control + X Mode Off CTRL + X (KBDCAS0) CTRL + X function 11 0B VT Tab CTRL+ K hyperlink 12 0C FF Delete CTRL+ L list, left align 13 0D CR Enter / Ret CTRL+ M 14 0E SO Insert CTRL+ N New 15 0F SI ESC CTRL+ O Open 16 10 DLE F11 CTRL+ P Print 17 11 DC1 Home CTRL+ Q Quit 18 12 DC2 PrtScn CTRL+ R 19 13 DC3 Backspace CTRL+ S
Printable Characters (Continued) DEC HEX 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F Character $ % & ' ( ) * + , .
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 † ‡ ˆ ‰ Š ‹ Œ å ç ê ë è ï î ì Ä Å É æ Æ ô ö ò û ù ÿ Ö Ü ¢ £ ¥ ₧ ƒ á í ó ú ñ Ñ ª º ¿ ⌐ ¬ ½ ¼ Home End Page Up Page Down Right ALT Right CTRL Reserved Reserved Numeric Keypad Enter Numeric Keypad / F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Numeric Keypad + Num
Extended ASCII Characters (Continued) PS2 Scan Code DEC HEX CP 1252 ASCII Alternate Extended 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 ® ¯ ° ± ² ³ ´ µ ¶ · ¸ ¹ º » ¼ ½ ¾ ¿ À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Ð Ñ Ò Ó ¡ « » ░ ▒ ▓ │ ┤ ╡ ╢ ╖ ╕ ╣ ║ ╗ ╝ ╜ ╛ ┐ └ ┴ ┬ ├ ─ í ╞ ╟ ╚ ╔ ╩ ╦ ╠ ═ ╬ ╧ ╨ ╤ ╥ ╙ Control Break 0x9D Alt Sequence with 1 Character 0x36 Ctrl Sequence with 1 Character 0x1D A-8 AD AE
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 Ô Õ Ö × Ø Ù Ú Û Ü Ý Þ ß à á â ã ä å æ ç è é ê ë ì í î ï ð ñ ò ó ô õ ö ÷ ø ù ú ╘ ╒ ╓ ╫ ╪ ┘ ┌ █ ▄ ▌ ▐ ▀ α ß Γ π Σ σ µ τ Φ Θ Ω δ ∞ φ ε ∩ ≡ ± ≥ ≤ ⌠ ⌡ ÷ ≈ ° · · D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA Alternate Extend
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII 251 252 253 254 255 û ü ý þ ÿ √ ⁿ ² ■ FB FC FD FE FF PS2 Scan Code Alternate Extended ISO 2022/ISO 646 Character Replacements Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
Code Page Selection Method/Country Standard Keyboard Country Honeywell Code Page Option France ISO /IEC 646-69 3 83 Germany ISO/IEC646-21 4 84 Switzerland ISO /IEC 646-CH 6 86 Sweden / Finland (extended Annex C) ISO/IEC 646-11 2 82 Ireland ISO /IEC 646-207 73 97 Denmark ISO/IEC 646-08 8 88 Norway ISO/IEC 646-60 9 94 Italy ISO/IEC 646-15 5 85 Portugal ISO/IEC 646-16 13 92 Spain ISO/IEC 646-17 10 90 Spain ISO/IEC 646-85 51 91 A - 11
64 91 92 93 94 96 123 124 125 126 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E US 0 1 # $ @ [ \ ] ^ ` { | } ~ CA 54 95 # $ à â ç ê î ô é ù è û CA 18 96 # $ à â ç ê É ô é ù è û JP 28 98 # $ @ [ ¥ ] ^ ` { | } ⎯ CN 92 99 # ¥ @ [ \ ] ^ ` { | } ⎯ GB 7 87 £ $ @ [ \ ] ^ ` { | } ˜ FR 3 83 £ $ à ° ç § ^ µ é ù è ¨ DE 4 84 # $ § Ä Ö Ü ^ ` ä ö ü ß CH 6 86 ù $ à é ç ê î ô ä ö ü û
Sample Symbols UPC-A 0 123456 7890 Code 128 Code 128 Code 39 BC321 Code 93 123456-9$ Interleaved 2 of 5 1234567890 EAN-13 9 780330 290951 Codabar A13579B Straight 2 of 5 Industrial 123456
Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Car Registration Postnet Zip Code Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T
Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message Test Message
Programming Chart 0 1 2 3 4 5 6 7 8 9
Programming Chart A B C D E F Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.