Thermostat User Manual
English: Page 1 • Français : Page 6 • Español: Página 11
3 69-1959EFS—02
Wiring CT87N
[1] If wires will be connected to both R and Rc
terminals, remove the metal jumper.
[2]DonotconnectbothO and B if you have a
heat pump. Connect only the O wire. Wrap B
wire with electrical tape and do not use.
[3]DonotuseC, X or B. Wrap bare end of wire
with electrical tape.
Cover plate
(optional)
Thermostat
base
CT87N
Wiring CT87K
• 2-wire heat-only system: Connect one
wire to R terminal, one wire to W terminal.
• 3-wire hot water heat-only system: Connect
wires R to R, W to W, and Y to Y terminals.
R
W
Y
CT87K
1. Drillholesatpencil-marked
locations(3/16”fordrywall,
7/32”forplaster).
2. Use hammer to tap anchors
into holes until flush with
wall.
3. [Optional] Pull wires through
coverplate(ifneededtocover
marksleftbytheoldthermostat).
4. Pull wires through thermostat
base, position over anchors,
then insert mounting screws.
Check level if desired, then
tighten screws.
Mount thermostat base
1. Match each labeled wire with same
letterontheterminalblock(s).
2. Use a screwdriver to loosen screw
terminals, insert bare wire into
slots, then tighten screws.
3. Pushanyexcesswirebackintothe
wall opening.
Labels don't match?
If labels do not match letters on
thermostat, see table below.
Existing wires Connect to:
R• RH•4• V Terminal “R” [1]
Rc Terminal “Rc” [1]
O Terminal “O” [2]
B Terminal “B” [2]
G•F Terminal “G”
W•W1•H Terminal “W”
Y •Y1•M Terminal “Y”
C•X •B Do not use [3]
Connect wires