Operation Manual

17 69-0733—3
Remove wallplate from wall, and drill
3/16 inch holes in wall (if drywall) as marked.
For firmer material such as plaster or wood,
drill 7/32 inch holes. Gently tap anchors
(provided) into drilled holes until flush with
the wall.
Reposition wallplate over holes, pulling
wires through wiring opening. Loosely insert
two mounting screws into holes.
Level for appearance only; thermostat
functions properly even when not level.
Tighten mounting screws.
INSTALLATION
18 69-0733—3
STEP 6 Adjust System On-Time, Clock Display,
As Required
The thermostat on-time is factory-set for a
warm air, gas or oil heating system. If you are
installing it on another type of system, the on-
time must be adjusted accordingly by setting
screws 1A and 1B on the back of the thermo-
stat, using the heating system table in the
illustration as a guide. The system on-time
should be optimized with the type of system to
minimize room temperature swings. Setting the
screw out one turn means turning the screw
approximately 360° counterclockwise, or about
one complete turn.
In the unlikely event that you want longer fur-
nace on-time, readjust screws 1A and/or 1B as
follows:
First, turn both screws in completely, then ad-
just for system type:
Hot Water or High Efficiency—Set at the
Gravity Air/Water setting (1A—out one turn,
1B—out one turn).
Gas/Oil Warm Air—Set at the Hot Water or
High Efficiency setting (1A—leave in, 1B—
out one turn).
Electric Warm Air—Leave at the Gas/
Oil Warm Air setting (1A—leave in, 1B—
leave in).
M611B
LEVEL