Xenon™ XP 195X Series Area-Imaging Scanners and Bases Scanner Models: 1950g, 1950h, 1952g, 1952h, 1952g-BF, 1952h-BF Base Models: CCB01-010BT, CCB01-010BT-BF, CCB-H-010BT, CCB-H-010BT-BF User Guide
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
TABLE OF CONTENTS Customer Support ..................................................................................................................... xvii Technical Assistance .......................................................................................................... xvii Product Service and Repair ............................................................................................. xvii Limited Warranty .............................................................................
Keyboard Wedge ..........................................................................................................................15 Laptop Direct Connect ..............................................................................................................16 RS232 Serial Port.........................................................................................................................16 RS485 ..........................................................................................
Scanner to Bioptic Communication .....................................................................................38 Scanner-Bioptic Packet Mode..........................................................................................38 Scanner-Bioptic ACK/NAK Mode....................................................................................39 Scanner-Bioptic ACK/NAK Timeout ..............................................................................39 Chapter 3 - Cordless System Operation ....
Low Power Alert Flash Number .......................................................................................51 Low Power Alert Repeat ......................................................................................................52 Low Power Alert Beep ..........................................................................................................52 Reset Scanner .........................................................................................................................
Total Records...........................................................................................................................67 Delete Last Code....................................................................................................................68 Clear All Codes........................................................................................................................68 Transmit Records to Host............................................................................
Trigger Click ...................................................................................................................................84 Good Read and Error Indicators ............................................................................................84 Beeper – Good Read.............................................................................................................84 Beeper Volume – Good Read ..................................................................................
Character Activation ...................................................................................................................99 Activation Character.............................................................................................................99 End Character Activation After Good Read .................................................................99 Character Activation Timeout........................................................................................
Silent Mode with Long LED ........................................................................................... 120 Very Low Beeper (Nighttime Mode)............................................................................ 120 Low Beeper (Daytime Mode) ......................................................................................... 121 Quiet Operations - LED and Volume Settings .............................................................. 121 Linking LED Colors and Sound ..................
Terminal ID Table ................................................................................................................136 Data Format Editor Commands ..........................................................................................136 Send Commands ................................................................................................................136 Move Commands................................................................................................................
EAN/JAN-13 ............................................................................................................................... 180 ISBN Translate..................................................................................................................... 187 EAN/JAN-8 .................................................................................................................................. 187 MSI.....................................................................................
Chapter 9 - Imaging Commands ...............................................................217 Single-Use Basis .......................................................................................................................217 Command Syntax......................................................................................................................217 Image Snap - IMGSNP............................................................................................................
Chapter 12 - Product Specifications........................................................277 Xenon XP 1950g/1950h Corded Scanner Product Specifications ...................... 277 Xenon XP 1952g/1952h Cordless Scanner Product Specifications ................... 278 Xenon XP 1952g-BF/1952h-BF Scanner Product Specifications ....................... 280 CCB01-010BT/CCB01-010BT-BF Charge Base Product Specifications ..................................................................................................
Replace an Interface Cable in a Base .........................................................................293 Change a Scanner Battery ..............................................................................................294 Troubleshoot a Corded Scanner..........................................................................................294 Troubleshoot a Cordless System.........................................................................................295 Troubleshoot a Base .........
xvi Xenon XP User Guide
Customer Support Technical Assistance To search our knowledge base for a solution or to log in to the Technical Support portal and report a problem, go to www.hsmcontactsupport.com. For our latest contact information, see www.honeywellaidc.com/locations. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world.
xviii Xenon XP User Guide
CHAPTER 1 GET STARTED About This Manual This User Guide provides installation and programming instructions for the Xenon™ XP 1950 corded area-imaging scanners and the Xenon XP 1952 cordless area-imaging scanners. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell barcode scanners are factory programmed for the most common terminal and communications settings.
Connect the Device Connect with USB A scanner or a cordless base can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the device first, then to the computer. Corded Xenon XP Scanner USB Connection: Note: The power supply must be ordered separately, if needed. 2.
CCB-H-010BT/CCB-H-010BT-BF Base USB Connection: 3. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a barcode from the Sample Symbols, beginning on page 309. The unit defaults to a USB PC Keyboard. Refer to page 18 for other USB terminal settings. For additional USB programming and technical information, refer to “USB Application Note,” available at www.honeywellaidc.com.
Connect with Keyboard Wedge A scanner or cordless base can be connected between the keyboard and PC as a “keyboard wedge,” where the scanner provides data output that is similar to keyboard entries. The following is an example of a keyboard wedge connection: 1. Turn off power and disconnect the keyboard cable from the back of the terminal/computer. 2. Connect the appropriate interface cable to the device and to the terminal/ computer.
CCB01-010BT/CCB01-010BT-BF Base Keyboard Wedge Connection: CCB-H-010BT/CCB-H-010BT-BF Base Keyboard Wedge Connection: 4. Turn the terminal/computer power back on. The scanner beeps. 5. Verify the scanner or cordless base operation by scanning a barcode from the Sample Symbols, beginning on page 309. The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard. A carriage return (CR) suffix is added to barcode data.
Connect with RS232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. Note: For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer. Corded Xenon XP Scanner RS232 Serial Port Connection: Note: The power supply must be ordered separately, if needed. 3.
Base vertically, see Mount a CCB-H-010BT/CCB-H-010BT-BF Charge Base on page 10. CCB01-010BT/CCB01-010BT-BF Base RS232 Serial Port Connection: CCB-H-010BT/CCB-H-010BT-BF Base RS232 Serial Port Connection: 4. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 5. Once the scanner or cordless base has been fully connected, power up the computer. This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit.
Connect with RS485 A Xenon scanner or cordless base can be connected for an IBM POS terminal interface. 1. Connect the appropriate interface cable to the device, then to the computer. Corded Xenon XP Scanner RS485 Connection: Note: The power supply must be ordered separately, if needed. 2.
CCB01-010BT/CCB01-010BT-BF Base RS485 Connection: CCB-H-010BT/CCB-H-010BT-BF Base RS485 Connection: 3. Turn the terminal/computer power back on. The scanner beeps. 4. Verify the scanner or cordless base operation by scanning a barcode from the Sample Symbols, beginning on page 309. The scanner beeps once. For further RS485 settings, refer to RS485, page 16.
Mount a CCB01-010BT/CCB01-010BT-BF Charge Base 2.8 in. 72.1mm 3.35 in. 85.09mm 2.36 in. 59.84mm 8x32 thread x .39 in. (10mm) deep Mount a CCB-H-010BT/CCB-H-010BT-BF Charge Base The CCB-H-010BT/CCB-H-010BT-BF Base can be mounted on either a horizontal or vertical surface. Route the cables through the top, bottom, or sides of the base and secure the cables in the wireways. When mounted on a vertical surface, a locking system is used to secure the scanner when it is in the stand.
Unlocked position for horizontal mount Locked position for vertical mount Use 30mm screws, appropriate for the mounting surface material, to mount the base securely. Horizontal Mount 43.97mm (1.73") 72.97mm (2.87") 85.1mm (3.35") 72.37mm (2.85") 43.97mm (1.
Vertical Mount 38.92mm (1.53") 33.97mm (1.34") 15.07mm (0.59") 15.17mm (0.59") 100mm (3.94") 115.27mm (4.54") Reading Techniques The Xenon XP scanners have a view finder that projects a bright red aiming beam that corresponds to the scanner’s horizontal field of view. The aiming beam should be centered over the barcode, but it can be positioned in any direction for a good read.
Menu Barcode Security Settings Honeywell scanners are programmed by scanning menu barcodes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Barcode Security settings. Contact the nearest technical support office (see Technical Assistance on page xvii) for further information. Set Custom Defaults You have the ability to create a set of menu commands as your own, custom defaults.
custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings. Activate Custom Defaults Note: If using a cordless system, scanning this barcode also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in its base to re-establish the link. If using an Access Point, the linking barcode must be scanned.
CHAPTER 2 PROGRAM THE INTERFACE Introduction This chapter describes how to program your system for the desired interface. Program the Interface - Plug and Play Plug and Play barcodes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the barcode below.
Laptop Direct Connect For most laptops, scanning the Laptop Direct Connect barcode allows operation of the scanner in parallel with the integral keyboard. The following Laptop Direct Connect barcode also programs a carriage return (CR) suffix and turns on Emulate External Keyboard (page 31). Laptop Direct Connect with CR suffix RS232 Serial Port The RS232 Interface barcode is used when connecting to the serial port of a PC or terminal.
IBM Port 17 Interface IBM Port 9B HHBCR-2 Interface Each barcode above also programs the following suffixes for each symbology: Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 * 00 0A 0B UPC E 0A Code 128 ** 00 18 0B MaxiCode 00 2F 0B * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Inter
USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes also adds a CR suffix. USB Keyboard (PC) USB Keyboard (Mac) USB Japanese Keyboard (PC) USB HID Scan the following code to program the scanner for USB HID Barcode scanners. USB HID Barcode Scanner USB Serial If you are using a Microsoft® Windows® PC, you will need to download the latest driver from the Honeywell website (www.honeywellaidc.
CTS/RTS Emulation CTS/RTS Emulation On * CTS/RTS Emulation Off ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off Verifone® Ruby Terminal Scan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This barcode sets the baud rate to 1200 bps and the data format to 8 data bits, mark parity bit, 1 stop bit.
Gilbarco® Terminal Scan the following Plug and Play code to program the scanner for a Gilbarco terminal. This barcode sets the baud rate to 2400 bps and the data format to 7 data bits, even parity, 2 stop bits.
Wincor Nixdorf Terminal Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal. This barcode sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Wincor Nixdorf Terminal Settings Wincor Nixdorf Beetle™ Terminal Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal.
Wincor Nixdorf RS232 Mode A Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf RS232 Mode A terminal. This barcode sets the baud rate to 9600 bps and the data format to 8 data bits, odd parity, 1 stop bit.
Keyboard Countries (Continued) Belarus Belgium Bosnia Brazil Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Xenon XP User Guide 23
Keyboard Countries (Continued) Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faroese Finland France Gaelic Germany Greek 24 Xenon XP User Guide
Keyboard Countries (Continued) Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Xenon XP User Guide 25
Keyboard Countries (Continued) Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta 26 Xenon XP User Guide
Keyboard Countries (Continued) Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia Russian (MS) Russian (Typewriter) SCS Serbia (Cyrillic) Xenon XP User Guide 27
Keyboard Countries (Continued) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) Switzerland (German) Tatar Turkey F 28 Xenon XP User Guide
Keyboard Countries (Continued) Turkey Q Ukrainian United Kingdom United States (Dvorak) United States (Dvorak left) United States (Dvorak right) United States (International) Uzbek (Cyrillic) Keyboard Wedge Modifiers ALT Mode If your barcode contains special characters from the extended ASCII chart, for example, an e with an accent grave (è), you will use ALT Mode. (See Extended ASCII Characters on page 301.) Note: Scan the ALT mode barcode after scanning the appropriate Keyboard Country code.
If your keystrokes require the ALT key and 3 or 4 characters, scan the 3 Characters or 4 Characters barcode. The data is then output with the special character(s) for values 00-255. Default = Off. * Off 3 Characters 4 Characters Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings. Default = Regular. Regular is used when you normally have the Caps Lock key off.
Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off. This selection can only be used with systems that have an LED that notes the Caps Lock status (AT keyboards). Automatic Caps Lock Autocaps via NumLock barcode should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock.
Convert All Characters to Upper Case Convert All Characters to Lower Case Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page 300. Only codes 00 through 1F are converted (the first column of the chart). Default = Off.
Default = Control + X Mode Off. Windows Mode Control + X Mode On * Control + X Mode Off DOS Mode Control + X Mode On Windows Mode Prefix/Suffix DOS Mode Control + X Mode On with Windows Mode Prefix/Suffix Supports ALT 3 Digit HEX Mode Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off. Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad. Default = Off.
Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off. Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 115,200.
19200 38400 57,600 * 115,200 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character. Default = 8. Stop Bits sets the stop bits at 1 or 2. Default = 1. Parity provides a means of checking character bit patterns for validity.
7 Data, 2 Stop, Parity Odd 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd 8 Data, 1 Stop, Parity Mark RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the time-out. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out. A transaction on the CTS line will also wake up the receiver.
Flow Control with Timeout: The scanner asserts RTS when it has data to send and waits for a delay (see RS232 Timeout on page 37) for CTS to be asserted by the host. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume. Default = RTS/CTS Off.
* XON/XOFF Off ACK/NAK After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the host. If ACK is received, the communications cycle is completed and the scanner looks for more barcodes. If NAK is received, the last set of barcode data is retransmitted and the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On barcode below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off.
Scanner-Bioptic ACK/NAK Mode Bioptic ACK/NAK On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent. The Scanner-Bioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response. Default = Bioptic ACK/NAK Off. * Bioptic ACK/NAK Off Bioptic ACK/NAK On Scanner-Bioptic ACK/NAK Timeout This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response.
40 Xenon XP User Guide
CHAPTER 3 CORDLESS SYSTEM OPERATION How the Cordless Charge Base/Access Point Works A CCB01-010BT/CCB01-010BT-BF or a CCB-H-010BT/CCB-H-010BT-BF cordless charge base or an Access Point provides the link between the cordless scanner and the host system. The base/Access Point contains an interface assembly and an RF communication module. The RF communication module performs the data exchange between the cordless scanner and the interface assembly.
Link the Scanner to an Access Point Note: Linking to an Access Point is only supported by Xenon XP 1952 models. Turn on the computer (laptop/desktop). Plug the interface cable into the Access Point first and then into the appropriate port on the computer. The page button lights up when the connection to the host is made. Page Button Scan the linking barcode on the top of the Access Point to establish a connection between the Access Point and the scanner.
When data is scanned, the data is sent to the host system via the base or Access Point. The cordless scanner recognizes data acknowledgment (ACK) from the base or Access Point. If it cannot be determined that the data has been properly sent to the base or Access Point, the scanner issues an error indication. You must then check to see if the scanned data was received by the host system. 1. Scanner reads code and gets ACK from base or Access Point. 2. Base or Access Point sends data to host.
of 328 feet (100m) or 33 feet (10m) between the scanner and base or Access Point, depending on the environment. See Flexible Power Management, page 62, for information about controlling this range. System Conditions The components of the cordless system interact in specific ways as you associate a scanner to a base or Access Point, as you move a scanner out of range, bring a scanner back in range, or swap scanners between two cordless systems.
Page Button When you press the page button on the base or Access Point, the scanners associated with that base or Access Point will begin beeping (3 short and 1 long beep). If you press the trigger on a scanner that is beeping in response, or press the page button on the base or Access Point a second time, all associated scanners will stop beeping. See Page on page 54 for further information about page button settings.
When the scanner is out of the base, the page button works normally. Default = Temporary Streaming Presentation Mode On. * Temporary Streaming Presentation Mode On To remove Temporary Streaming Presentation Mode, scan the barcode for Page Mode On page 54. Temporary Streaming Presentation Timeout Set a timeout for the length of time the illumination remains on and searching for barcodes when using Temporary Streaming Presentation Mode. Set the length for the timeout by scanning one of the barcodes below.
Place the scanner in the base that is connected to an appropriate power supply. Use only a Listed Limited Power Source (LPS) or Class 2 type power supply with output rated 5 to 5.2Vdc, 1A. Note: If you are powering the base through the interface cable (for example, a USB cable) and not using an external power supply plugged into the aux port, the current available for charging is reduced and charge times are increased.
• Do not pierce, strike or step on batteries or subject batteries to strong impacts or shocks. • Do not disassemble or modify batteries. Caution: Danger of explosion if batteries are incorrectly replaced. Dispose of used batteries according to the recycle program for batteries as directed by the governing agency for the country where the batteries are to be discarded.
Scanner Communication and Scanning The following feedback is provided by the scanner and indicates communication and scanning status.
Base/Access Point Communication and Scanning The following feedback is provided by the base (red LED) or Access Point (blue LED) and indicates communication and scanning status. LED Communication Condition Off USB suspend On continuously Power on, system idle Short blinks in multiple pulses. Occurs while transferring data to/from the RF module or the Host port.
Low Power Alerts Note: Low Power Alerts are only supported by battery-free scanners Xenon XP 1952g-BF and Xenon XP 1952h-BF. Low power alerts allow you to customize battery-free scanner LEDs to flash in different patterns when the charge level is low. Use the barcodes that follow to customize the settings for the power range being configured, the number of flashes per alert, the interval between flashes, the number of alerts, and the interval between alerts.
Interval Between Flashes Set the length of time, in seconds, between the LED flashes for a low power alert. To set the interval, scan the barcode below and then scan a digit (1-9) barcode from the Programming Chart, beginning on page 311, then Save. Default = 2 seconds between flashes. Interval Between Flashes Low Power Alert Repeat Set how many times you want the low power flash pattern (flashes and intervals) to repeat.
*Low Power Alert Beep On Reset Scanner Scanning this barcode reboots the scanner and causes it to relink with the base or Access Point. Reset Scanner Scan While in Base Cradle If you want to be able to scan barcodes while the scanner is in the base cradle, scan the Scan in Cradle On barcode below. If you want to only allow scanning when the scanner is out of the base cradle, scan Scan in Cradle Off. If you want the scanner to shut down when in the base cradle, scan Shut Down Scanner in Cradle.
When Base Charge Off is selected, the scanner does not charge when the scanner is in the base cradle. When External or Interface Cable Power is selected, the scanner charges from the base’s external power supply, if there is one. If there is no external power supply to the base, the scanner charges from the interface cable. When External Power Only is selected, the scanner only charges from the base’s external power supply. If there is no external power supply, the scanner does not charge.
Page Mode Off Page Pitch When you press the page button on the base or Access Point, the scanners associated with that base or Access Point will begin beeping (see Page Button on page 45). You can set the pitch of the paging beep for each scanner by scanning one of the following barcodes. Default = Low.
Number of Beeps - Base Error The number of beeps and LED flashes emitted by the base for an error condition can be programmed from 1 - 9. For example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response to an error. To change the number of error beeps, scan the barcode below and then scan a digit (1-9) from the Programming Chart, beginning on page 311, then Save. Default = 1.
Charge Only Mode There may be times when you want to charge your scanner, but not link to the base. For example, if a scanner is linked to an Access Point or other Bluetooth device and you need to charge the scanner, but want to retain your existing link. In order to program the base for Charge Only Mode, you must link a scanner to it. Once the scanner is linked to the base, scan the Charge Only Mode barcode. Any subsequent scanners placed in that base will charge without linking to it.
Locked Link Mode - Single Scanner If you link a scanner to a base or an Access Point using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base, or if the Access Point linking barcode is scanned. If you do place a different scanner into a base, it will charge the scanner, but the scanner will not be linked.
Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base or an Access Point, scan the Override Locked Scanner barcode below with a new scanner and place that scanner in the base, or scan the Access Point linking barcode. The locked link will be overridden; the broken or lost scanner’s link with the base or Access Point will be removed, and the new scanner will be linked.
The sounds are as follows: Setting Sound 0 3 long beeps, medium pitch 1 3 long beeps, high pitch 2 4 short beeps, medium pitch 3 4 short beeps, high pitch 4 single chirps, medium pitch 5 2 chirps, then 1 chirp, medium pitch 6 single chirps, high pitch 7 2 chirps, then 1 chirp, high pitch Base Alarm Type Scanner Alarm Type Scanner Power Time-Out Timer When there is no activity within a specified time period, the scanner enters low power mode.
If there are no trigger pulls during the timer interval, the scanner goes into power down mode. Whenever the trigger is enabled, the timer is reset. The scanner will not go into power down mode when it is in the base and charging. Default = 3600 seconds. 0 seconds 200 seconds 400 seconds 900 seconds * 3600 seconds 7200 seconds Note: When the scanner is in power down mode, press the trigger to power the unit back up.
Flexible Power Management If you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can turn down the power output of the scanner. This reduces the range between the scanner and a base or an Access Point as shown in the following illustration: Scanner 802.
Xenon XP 1952g-BF/1952h-BF Scan one of the barcodes below to set the scanner’s power output to Full Power (100%), Medium High Power (87%), Medium Power (50%), or Low Power (1%). Default = Full Power. * Full Power Medium High Power Medium Power Low Power Batch Mode Batch mode is used to store barcode data when a scanner is out of range of its base or Access Point, or when performing inventory.
the scanner’s buffer space is full, any barcodes scanned generate an error tone. In order to scan barcodes again, the data must be transmitted to the base or Access Point. Once the data is transmitted, it is cleared in the scanner. Persistent Batch Mode is the same as Inventory Batch Mode, except that once the data is transmitted to the base or Access Point, it is retained in the scanner. If you want to transmit more than once, you can do so using this mode.
Flash Storage: The scanner writes any untransmitted data to flash memory prior to powering down. The data will still be there when the scanner powers back up. However, the scanner will power down, even with untransmitted data, if it reaches a power down timeout or if the battery or charge pack power is very low. RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base or Access Point, even if it reaches a power down timeout.
For example, if the Quantity 5 barcode is scanned after the quantity has been set to 1234, then the 1 is dropped, the quantity will be 2345. Example: Add a quantity of 5 for the last item scanned. 1. Scan the item's barcode. 2. Scan the quantity 5 barcode. Example: Add a quantity of 1,500 for the last item scanned. 1. Scan the item's barcode. 2. Scan the quantity 1 barcode. 3. Scan the quantity 5 barcode. 4. Scan the quantity 0 barcode. 5. Scan the quantity 0 barcode.
Quantity Codes (Continued) 4 5 6 7 8 9 Batch Mode Output Order When batch data is transmitted, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in first-out). Default = Batch Mode FIFO. * Batch Mode FIFO Batch Mode LIFO Total Records If you wish to output the total number of barcodes scanned when in Batch Mode, scan Total Records.
Total Records Delete Last Code If you want to delete the last barcode scanned when in Batch Mode, scan Delete Last Code. Delete Last Code Clear All Codes If you want to clear the scanner’s buffer of all data accumulated in Batch Mode, scan Clear All Codes. Clear All Codes Transmit Records to Host If you are operating in Inventory Batch Mode (see Inventory Batch Mode on page 64), you must scan the following barcode to transmit all the stored data to the host system.
Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system, the transmission of those scans is too fast for the application to process. To program a transmit delay between accumulated scans, scan one of the following delays. Default = Off. Note: In most cases, a short (250 ms (milliseconds)) delay is ideal, however, longer delays may be programmed. Contact Technical Support (page xvii) for additional information.
Scanner Name You may assign a name to each scanner you are using for identification purposes. For example, you may want to have a unique identifier for a scanner that is receiving imaging commands sent from the base or Access Point. The default name is in the format “ScannerName_Model_SN_XXXXXXXXXX” If you have more than one scanner linked to a base, and they all have the same name, the first scanner linked to the base receives commands.
Reset You may also scan the Scanner Name barcode below and scan a number for the scanner name. For example, if you wanted to name the linked scanner “312,” you would scan the barcode below, scan the 3, 1, and 2 barcodes on the Programming Chart, beginning on page 311, then Save. Scan the Reset barcode and wait for the scanner to relink to the base. Scanner Name Application Work Groups Note: A base can only have on Xenon XP 1952-BF scanner linked to it.
Application Work Group Selection This programming selection allows you to assign a scanner to a work group by scanning the barcode below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. Default = Group 0. * Group 0 Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Reset the Factory Defaults: All Application Work Groups The following barcode defaults all of the work groups to the factory default settings.
To see what the factory default settings are, refer to the table of Menu Commands, beginning on page 246. The standard product default settings for each of the commands are indicated by an asterisk (*). Note: Scanning this barcode also causes both the scanner and the base or Access Point to perform a reset and become unlinked. The scanner must be placed in the base, or the Access Point linking barcode must be scanned to re-establish the link. Refer to Scanner Modes, page 56 for additional information.
version 2.1 or higher. When SSP is on, no PIN is required for pairing. Turn SSP off if you are connecting to a Bluetooth device that is not using a compatible Bluetooth version. Default = Bluetooth SSP On. * Bluetooth SSP On Bluetooth SSP Off Bluetooth HID Keyboard Connect Your scanner can be paired with Bluetooth-capable devices, such as personal computers, laptops, and tablets, so that scanned data appears on your device screen as though it was entered on the keyboard.
0 1 2 3 4 5 6 7 8 9 Save Xenon XP User Guide 75
Virtual Keyboard Once your scanner has been connected directly to an iPad, smart phone, or laptop, you can toggle the virtual keyboard on your device with a quick double pull of the scanner trigger. Bluetooth HID Keyboard Disconnect If your scanner has been connected directly to an iPad, smart phone, or laptop, you must disconnect it in order to once again communicate with the base or Access Point. Scan the Bluetooth HID Keyboard Disconnect barcode to unlink the scanner from the currently linked host.
PDAs/Mobility Systems Devices You may also use the scanner with a PDA or a Honeywell Mobility Systems device. Scan the barcode below and follow the instructions supplied with your Bluetooth device to locate the scanner, and connect with it. BT Connection - PDA/Mobility Systems Device Change the Scanner’s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features. Your scanner’s default PIN is 1234, which you may need to enter the first time you connect to your PDA or PC.
The table below shows the results of the Auto Reconnect On and Off settings: Event Auto Reconnect On Auto Reconnect Off Scanner out of range Relink occurs automatically. If maximum number of link attempts is unsuccessful, then the scanner must be relinked by either pulling the trigger, placing the scanner in the base, or scanning the Access Point linking barcode. (See Maximum Link Attempts on page 78.) The scanner is relinked by pulling the trigger, or scanning the Access Point linking barcode.
Relink Time-Out Relink Time-Out controls the idle time between relink attempts. An attempt to link a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the time when the scanner is actually attempting a contact. Relink Time-Out controls the amount of time, in seconds, that elapses between the end of one connection attempt and the start of the next. Note: The length of time for an attempt depends on the number of scanners connected to a base unit or Access Point.
saved in batch mode. After one hour, the scanner powers off and batch mode data is lost. Refer to Auto Reconnect Mode, page 77, to review other events that can start the relink process. Example: Auto Reconnect Mode set to 1 Maximum Link Attempts set to 0 Relink Time-Out set to 10 Scanner Power Time-Out Timer set to 1800 Note: See Scanner Power Time-Out Timer on page 60. The scanner attempts to connect to the base or Access Point every 15 seconds, measured from one attempt start to the next attempt start.
The commands to which the scanner responds are listed on page 82. The [ESC] is a 1B in hex. A typical command string is y [ESC] x, where “y” is the application work group number, “[ESC] x” is the escape command, and the comma is the terminator, which is required. (When “y” is not specified, the command is sent to the default Application Work Group 0.) Example: Commands may be strung together to create custom response sequences. An example of a command string is listed below.
Host ACK Timeout You can set a timeout for the length of time the scanner waits for a valid escape command when using Host Acknowledgment Mode. Set the length (in seconds) for a timeout by scanning the following barcode, then setting the timeout (from 1-90 seconds) by scanning digits from the Programming Chart, beginning on page 311, then Save. Default = 10. Host ACK Timeout Host ACK Responses 82 Command Action [ESC] a, Double beeps to indicate a successful menu change was made.
CHAPTER 4 INPUT/OUTPUT SETTINGS Power Up Beeper The scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base can also be programmed to beep when it is powered up. Scan the Off barcode(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner.
Beep on BEL Character You may wish to force the scanner to beep upon a command sent from the host. If you scan the Beep on BEL On barcode below, the scanner will beep every time a BEL character is received from the host. Default = Beep on BEL Off. *Beep on BEL Off Beep on BEL On Trigger Click To hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On barcode below. Scan the Trigger Click Off code if you don’t wish to hear the click.
Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High for Xenon XP, Low for Xenon XP healthcare scanners. * Low Medium * High Off Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium.
Vibrate – Good Read The scanner vibrates once when a barcode is successfully read, and twice when a programming barcode is successfully read. When a programming barcode is unsuccessful, the scanner emits one long vibration (2 times the Vibrate Duration length). Scan Vibrate - Good Read Off to keep the scanner from vibrating. Default = Vibrate - Good Read Off.
Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED - Good Read On LED - Good Read Off Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read.
to an error. To change the number of error beeps, scan the barcode below and then scan a digit (1-9) barcode from the Programming Chart, beginning on page 311, then Save. Default = 1. Number of Error Beeps/LED Flashes Good Read Delay This sets the minimum amount of time before the scanner can read another barcode. Default = 0 ms (No Delay).
Trigger Modes Manual Trigger When in manual trigger mode, the scanner scans until a barcode is read, or until the trigger is released. Two modes are available, Normal and Enhanced. Normal mode offers good scan speed and the longest working ranges (depth of field). Enhanced mode will give you the highest possible scan speed but slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range. Default = Manual TriggerNormal.
Trigger Number This sets the number of trigger presses required to activate the Trigger Toggle Mode. 2 Quick Triggers 3 Quick Triggers 4 Quick Triggers Trigger Timing This sets the timing of the trigger presses in order to qualify as a trigger toggle, rather than a regular trigger press. After scanning the Trigger Timing barcode, set the time-out duration (from 50-2,000 milliseconds) by scanning digits from the Programming Chart, beginning on page 311, then Save. Default = 400ms.
Serial Trigger You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 244). You must be in a serial interface mode in order to use serial triggering. Refer to RS232 Serial Port (page 16) or USB Serial (page 18) for further information. When in serial mode, the scanner scans until a barcode has been read or until the deactivate command is sent.
Triggered Presentation Mode This mode uses light to detect the presence of an object. Default = Ambient and Scanner Light. Ambient Light Only *Ambient and Scanner Light Presentation LED Behavior after Decode When a scanner is in presentation mode, the LED aimer dims 30 seconds after a barcode is decoded. If you wish to dim the LED aimer immediately after a barcode is decoded, scan the LEDs Off barcode, below. Default = LEDs On.
0% Barcode 1 10 Barcode 2 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100% Note: A barcode needs only to be touched by the centering window in order to be read. It does not need to pass completely through the centering window. Scan Presentation Centering On, then scan one of the following barcodes to change the top, bottom, left, or right of the centering window.
Left of Presentation Centering Window Right of Presentation Centering Window In-Stand Sensor Mode Note: The In-Stand Sensor feature only applies to Xenon XP 1950g, 1950h, 1952g, and 1952h products. It does not apply to the Xenon XP 1952-BF products. This feature senses when the scanner is removed from the stand and tells it to begin manual triggering.
* Poor Quality 1D Reading Off Poor Quality PDF Codes This setting improves the scanner’s ability to read damaged or badly printed PDF codes by combining information from multiple images. It is useful when a complete barcode cannot be seen in one image. This setting does not affect 1D barcode reading. Default = Poor Quality PDF Reading On. *Poor Quality PDF Reading On Poor Quality PDF Reading Off Low Resolution PDF Codes This setting improves the scanner’s ability to read low resolution PDF codes.
CodeGate™ When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system. The scanner remains on, scanning and decoding barcodes, but the barcode data is not transmitted until the trigger is pressed. When CodeGate is Off, barcode data is transmitted when it is decoded. Default = CodeGate Off Out-ofStand.
Streaming Presentation In-Stand This option is available when using In-Stand Sensor Mode, page 94. You may program a specific Streaming Presentation Mode for in-stand scanning, and a Manual Trigger mode for out-of-stand scanning. To do this, you must first scan the preferred Streaming Presentation mode (Normal or Enhanced), then scan the Manual Trigger mode (Normal or Enhanced) you want to use. Hands Free Time-Out The Scan Stand and Presentation Modes are referred to as “hands free” modes.
Extra Long (2000 ms) User-Specified Reread Delay If you want to set your own length for the reread delay, scan the barcode below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the Programming Chart, beginning on page 311, then Save. User-Specified Reread Delay 2D Reread Delay Sometimes 2D barcodes can take longer to read than other barcodes. If you wish to set a separate Reread Delay for 2D barcodes, scan one of the programming codes that follows.
Character Activation You may use a character sent from the host to trigger the scanner to begin scanning. When the activation character is received, the scanner continues scanning until either the Character Activation Timeout (page 4-100) is reached, the deactivation character is received (see Deactivation Character on page 100), or a barcode is transmitted.
End Character Activation After Good Read Character Activation Timeout You can set a timeout for the length of time the illumination remains on and attempting to decode barcodes when using Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following barcode, then setting the timeout (from 1-300,000 milliseconds) by scanning digits from the Programming Chart, beginning on page 311, then Save. Default = 30,000 ms.
Illumination Lights If you want the illumination lights on while reading a barcode, scan the Lights On barcode, below. However, if you want to turn just the lights off, scan the Lights Off barcode. Default = Lights On. Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (page 102). * Lights On Lights Off Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken.
User-Specified Aimer Delay If you want to set your own length for the duration of the delay, scan the barcode below, then set the time-out by scanning digits (0 - 4,000 ms) from the Programming Chart, beginning on page 311, then Save. Delay Duration Aimer Mode This feature allows you to turn the aimer on and off. When the Interlaced barcode is scanned, the aimer is interlaced with the illumination LEDs.
Single Code Centering Scan Single Code Centering to target the barcode closest to the center of the image. Singling out a barcode in this manner increases scanning accuracy when there are multiple barcodes close together. Single Code Centering Custom Centering Use the following settings to customize your centering window. If a barcode is not touched by a predefined window, it will not be decoded or output by the scanner.
does not need to pass completely through the centering window. Scan Centering On, then scan one of the following barcodes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits from the Programming Chart, beginning on page 311, then Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
If the time-out period expires before a high priority symbology is read, the scanner will read any barcode in its view (low priority or unspecified). If there is no barcode in the scanner’s view after the time-out period expires, then no data is reported. Note: A low priority symbol must be centered on the aiming pattern to be read. Scan a barcode below to enable or disable Preferred Symbology. Default = Preferred Symbology Off.
Preferred Symbology Time-out Once you have enabled Preferred Symbology and entered the high and low priority symbologies, you must set the time-out period. This is the period of time the scanner will search for a high priority barcode after a low priority barcode has been encountered. Scan the barcode below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the Programming Chart, beginning on page 311, then Save. Default = 500 ms.
1. If you are using barcodes to create your output sequence, scan Enter Output Sequence on page 110. 2. Code I.D. On the Symbology Charts on page 297, find the symbology to which you want to apply the output sequence format. Make a note of the hex value for that symbology. If you are using barcodes to create your output sequence, scan the 2 digit hex value from the Programming Chart, beginning on page 311. 3.
SEQISUAdd suffix to partial output sequences. SEQISEAdd separators to partial output sequences. TRGSTOTimeout for partial output sequences. FFTermination string. Examples outlining how to use these commands are shown below. Output Sequence Example 1 - Three Symbologies In this example, you are scanning PDF417, Code 128, and Code 39 barcodes, but you want the scanner to output Code 39 first, Code 128 second, and PDF417 third.
The data is output as: CODE39SMPLTSTMSGCODE128MSGPDF417 See the next example to further refine this output. Output Sequence Example 2 - Three Symbologies with <> Separators In this example, you are scanning the same three barcodes, but you want <> brackets and a carriage return and line feed to separate your output.
3E right bracket (>) And add the carriage return and line feed as a suffix: SEQSUF99 separator for suffixes, 99 = all symbologies 0D carriage return 0A line feed The whole command line would look like this: SEQBLK62999943FF6A999954FF7299994DFFSEQSEP993C3ESEQSUF990D0 A The data is output as: Enter Output Sequence If you are using barcodes to create your output sequence, scan Enter Output Sequence to begin scanning your string.
You would use the same command line as shown in Output Sequence Example 2 Three Symbologies with <> Separators (page 109): SEQBLK sequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39, 9999 = all lengths 43 start character match for Code 39, 43h = "C" FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128, 9999 = all lengths 54 start character match for Code 128, 54h = “T” FF term
3E right bracket (>) 50 P 41 A 52 R 54 T 49 I 41 A 4C L 3C left bracket (<) The whole command line would look like this: SEQBLK62999943FF6A999954FF7299994DFFSEQSEP993C3ESEQSUF990D0 ASEQTTS1SEQISU993E5041525449414C3C The data is output as: >PARTIAL< Discard Partial Output Sequence If you want to discard partial sequences when the output sequence operation is terminated before completion, scan Discard Partial Sequence.
The number of timeouts specified should correspond to the number of codes in the sequence defined by SEQBLK. You can specify one additional timeout, which will apply to codes not matching any member of the sequence. This can be useful if Require Output Sequence is On/Not Required. If you do not specify an additional timeout for codes not in the defined sequence, the last timeout specified by SEQTIM will apply.
Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is, or formatted according to the partial sequence output format (see Partial Sequence on page 110).
* Error Tone - Partial Sequence Output Multiple Symbols When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the scanner’s trigger. If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, beeping and or vibrating (if turned on) for each read. The scanner attempts to find and decode new symbols as long as the trigger is pulled. The maximum number of barcodes read is 21.
Video Reverse Video Reverse is used to allow the scanner to read barcodes that are inverted. The Video Reverse Off barcode below is an example of this type of barcode. Scan Video Reverse Only to read only inverted barcodes. Scan Video Reverse and Standard Barcodes to read both types of codes. Note: After scanning Video Reverse Only, menu barcodes cannot be read. You must scan Video Reverse Off or Video Reverse and Standard Barcodes in order to read menu barcodes.
Working Orientation Some barcodes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright.
118 Xenon XP User Guide
CHAPTER 5 HEALTHCARE SETTINGS The following settings have been developed to enhance scanning in a healthcare environment. These settings are only supported by the Xenon XP 1950h scanner and the Xenon XP 1952h and Xenon XP 1952h-BF scanner and base. They allow you to set quickly configure streaming presentation, and to set the scanner and base to quiet modes for scanning that do not disturb resting patients.
Silent Mode with Long LED Scan the following barcode to completely silence the scanner and base. The scanner beep, base beep, base and scanner power up beep, and scanner linking sounds are all silenced. When a barcode is scanned, the LED and aimer remain solidly lit for 1 second. Green indicates a good scan, red indicates a bad scan.
Low Beeper (Daytime Mode) The following barcode sets all sounds to on, but at a low volume. The scanner beep, base beep, base and scanner power up beep, and scanner linking sounds are all set to low volume. Daytime Mode Cordless Scanner and Base Daytime Mode Corded Scanner To reset your scanner and base to default sounds, refer to Reset the Custom Defaults (page 245).
Number of LED Flashes If you have silenced the scanner’s beeper, you may set the number of times the LED flashes when reading barcodes. Default = 1 LED Flash. Note: If you have set LED Solid (No Flash) (page 123), to anything but Off, that setting will override the LED Flash settings. In that case, scan the LED Solid Off barcode to turn off this feature, then scan the LED Flash code you wish to use.
LED Solid (No Flash) Under normal operations, the scanner’s LED flashes once for a good read. You may set the LED to remain on for a length of time after a good read instead of flashing. Default = LED Solid Off (Resume Flash). * LED Solid Off (Resume Flash) LED Solid 1 Second LED Solid 3 Seconds LED Solid 5 Seconds If you have scanned a barcode and don’t want to wait for the LED to turn off, press the trigger a second time and the LED turns off. You can then scan the next barcode.
Page Volume Medium Page Volume High Out-of-Range Alarm Volume Note: This setting is not supported by the Xenon XP 1950h scanner. If your scanner is out range of the base, an alarm sounds from both your base and scanner. If your scanner is out range of an Access Point, an alarm sounds from just the scanner.
Scanner Alarm Volume Medium Base Alarm Volume High Scanner Alarm Volume High Out-of-Range Delay Note: This setting is not supported by the Xenon XP 1950h scanner. When using the Out-of-Range Alarm settings, the length of the delay for the alarm is set with an Out-of-Range Delay. When the scanner is out of range of the base or Access Point, the alarm will delay for a set length of time before going off.
126 Xenon XP User Guide
CHAPTER 6 DATA EDIT Prefix/Suffix Overview When a barcode is scanned, additional information is sent to the host computer along with the barcode data. This group of barcode data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data.
• Enter prefixes and suffixes in the order in which you want them to appear on the output. • When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an added prefix or suffix character. • The maximum size of a prefix or suffix configuration is 200 characters, which includes header information. Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 129). Step 2.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit hex value from the Symbology Chart (included in the Symbology Charts, beginning on page 297) for the symbology from which you want to clear the prefix or suffix. Step 3. Scan the 2 digit hex value from the Programming Chart, beginning on page 311 or scan 9, 9 for all symbologies. Your change is automatically saved.
Clear All Suffixes Function Code Transmit By default, all ASCII control characters are transmitted with barcode data. These non-printable characters are translated into predefined key strokes, or CTRL+X functions (see ASCII Conversion Chart (Code Page 1252), beginning on page 300). If these key strokes interfere with your host’s software application, scan Disable to keep these ASCII control characters from being transmitted. Default = Enable.
To remove this delay, scan the Intercharacter Delay barcode, then set the number of delays to 0. Scan the Save barcode from the Programming Chart, beginning on page 311. Note: Intercharacter delays are not supported in USB serial emulation. User Specified Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed after the transmission of a particular character of scanned data.
To remove this delay, scan the Interfunction Delay barcode, then set the number of delays to 0. Scan the Save barcode from the Programming Chart, beginning on page 311. Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission. Scan the Intermessage Delay barcode below, then scan the number of 5ms delays, and the Save barcode from the Programming Chart, beginning on page 311.
CHAPTER 7 DATA FORMAT Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in barcode data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None. Normally, when you scan a barcode, it is output automatically.
If you have changed data format settings, and wish to clear all formats and return to the factory defaults, scan the Default Data Format code below. * Default Data Format Show Data Format Scan the barcode below to show current data format settings. Data Format Settings Add a Data Format Step 1. Scan the Enter Data Format symbol (page 135). Step 2. Select Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats.
Chart, beginning on page 311. For example, 50 characters is entered as 0050. Note: 9999 indicates all lengths. Step 6. Editor Commands Refer to Data Format Editor Commands (page 136). Scan the symbols that represent the command you want to enter. Step 7. Scan Save to save your data format, or Discard to exit without saving your changes. Enter Data Format Save Discard Other Programming Selections • Clear One Data Format This deletes one data format for one symbology.
Save Discard Terminal ID Table Terminal USB Serial Keyboard Model(s) Terminal ID PC keyboard (HID) 124 Mac Keyboard 125 PC Keyboard (Japanese) 134 Serial (COM driver required) 130 HID POS 131 USB SurePOS Handheld 128 USB SurePOS Tabletop 129 RS232 TTL 000 RS232 True 000 RS485 (IBM-HHBCR 1+2, 46xx) 051 PS2 compatibles 003 AT compatibles 002 Data Format Editor Commands When working with the Data Format Editor, a virtual cursor is moved along your input data string.
Send a number of characters F2 Include in the output message a number of characters followed by an insert character. Start from the current cursor position and continue for “nn” characters or through the last character in the input message, followed by character “xx.” Syntax = F2nnxx where nn stands for the numeric value (00-99) for the number of characters, and xx stands for the insert character’s hex value for its ASCII code.
Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex value for its ASCII code, and xx stands for the insert character’s hex value for its ASCII code.
42 is the hex value for B The data is output as: 1234567890 Send all but the last characters E9 Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is moved forward to one position past the last input message character included. Syntax = E9nn where nn stands for the numeric value (00-99) for the number of characters that will not be sent at the end of the message.
B9 and BA Example: Look for the string “AB” and insert 2 asterisks (**) Using the barcode above, send all characters up to but not including “AB.” Insert 2 asterisks at that point, and send the rest of the data with a carriage return after.
B3 is the “Insert symbology name” command F4 is the “Insert a character multiple times” command 20 is the hex value for a space 01 is the number of times the space character is sent B4 is the “Insert barcode length” command F4 is the “Insert a character multiple times” command 20 is the hex value for a space 01 is the number of times the space character is sent F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: Code128 20 1234567890ABCDEFGHIJ Insert key strokes
If there are three keystrokes, the syntax would change from B5xxssnn for one keystroke to B5xxssnnssnnssnn. An example that would insert "abc" is as follows: B503001F00320030F833. Note: Key modifiers can be added together when needed. The sum is converted to hexadecimals. Example: Control Left+Shift Left = 17, converted to hexadecimal = 11. Move Commands Move the cursor forward a number of characters F5 Move the cursor ahead “nn” characters from current cursor position.
FE and F7 Example: Manipulate barcodes that begin with a 1 Search for barcodes that begin with a 1. If a barcode matches, move the cursor back to the beginning of the data and send 6 characters followed by a carriage return.
F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: DEFGHIJ Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 300 for decimal, hex and character codes.
Search backward for a string B1 Search backward for “s” string from the current cursor position, leaving cursor pointing to “s” string. Syntax = B1nnnnS where nnnn is the string length (up to 9999), and S consists of the ASCII hex value of each character in the match string. For example, B1000454657374 will search backward for the first occurrence of the 4 character string “Test.” Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 300 for decimal, hex and character codes.
Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number of suppressed characters in the list, and xxyy .. zz is the list of characters to be suppressed.
If the barcode has characters that the host application does not want included, you can use the E4 command to replace those characters with something else. In this example, you will replace the zeros in the barcode above with carriage returns.
EC Example: Only output the data if the barcode begins with a number If you want only data from barcodes that begin with a number, you can use EC to check for the number. Command string: ECF10D EC is the “Check for a number” command F1 is the “Send all characters” command 0D is the hex value for a CR If this barcode is read, the next data format, if there is one, will be used on the data. If there is no other format, the format fails and the raw data is output as AB1234.
Insert a delay EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard emulation. Discard Data B8 Discards types of data. For example, you may want to discard Code 128 barcodes that begin with the letter A. In step 4 (page 134), select 6A (for Code 128), and in step 5, select 9999 (for all lengths).
requirements generates an error tone and the data in that barcode is not transmitted. If you wish to process this type of barcode without generating an error tone, see Data Format Non-Match Error Tone. • Data Format Required, Drop Prefix/Suffix Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone.
Data Format Non-Match Error Tone Off Primary/Alternate Data Formats You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the barcodes below. Primary Data Format Data Format 1 Data Format 2 Data Format 3 Single Scan Data Format Change You can also switch between data formats for a single scan.
Single Scan-Data Format 1 Single Scan-Data Format 2 Single Scan-Data Format 3 152 Xenon XP User Guide
CHAPTER 8 SYMBOLOGIES This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults.
All Symbologies For best scanner performance, you should only enable the symbologies that you need. Scan All Symbologies Off to disable all symbologies, then enable the symbologies you need by scanning the On barcode for each symbology. All Symbologies Off Message Length Description You are able to set the valid reading length of some of the barcode symbologies. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length barcode data.
Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can program the scanner to read only Codabar barcodes with Modulo 16 check characters. Default = No Check Character.
Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. A 1 2 3 4 D D 5 6 7 8 A Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters.
Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Off If you are reading Code 39 barcodes, Codablock A should remain disabled. If you are enabling Codablock A (see Codablock A on page 193), you should disable Code 39. Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
When Check Character is set to Validate and Transmit, the scanner only reads Code 39 barcodes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character. * No Check Character Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 0-48.
Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Note: Trioptic Code (page 193) must be turned off while scanning Code 32 Pharmaceutical codes. On * Off Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the barcode symbol will be interpreted as a single character.
* Full ASCII Off Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 barcodes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 2-80.
NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Off Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data.
NEC 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Off Code 93 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information.
Code 93 Append This function allows the scanner to append the data from several Code 93 barcodes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 93 barcodes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in which the barcodes are read, deleting the first space from each.
Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off On * Off Straight 2 of 5 Industrial Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA On/Off On * Off Straight 2 of 5 IATA Redundancy If you are encountering errors when reading Straight 2 of 5 IATA barcodes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a barcode is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the barcode.
Maximum Message Length Matrix 2 of 5 Matrix 2 of 5 On/Off On * Off Matrix 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Code 11 Code 11 On/Off On * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits. One Check Digit * Two Check Digits Code 11 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Code 128 Code 128 On/Off * On Off If you are reading Code 128 barcodes, Codablock F should remain disabled. If you are enabling Codablock F (see Codablock F on page 194), you should disable Code 128. ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license.
the higher the redundancy count, the longer it will take to decode the barcode. To adjust the redundancy, scan the Code 128 Redundancy barcode below, then scan a redundancy count between 0 and 10 on the Programming Chart, beginning on page 311. Then scan the Save barcode. Default = 0. Code 128 Redundancy Code 128 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 0-80.
Character Replacements on page 304), and scan the value and the Save barcode from the Programming Chart, beginning on page 311. The data characters should then appear properly. Code 128 Code Page GS1-128 GS1-128 On/Off * On Off GS1-128 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80.
Telepen Telepen On/Off On * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
Maximum Message Length UPC-A UPC-A On/Off * On Off Note: To convert UPC-A barcodes to EAN-13, see Convert UPC-A to EAN-13 on page 180. UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but can be programmed so it is not transmitted (Off). Default = On. * On Off UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda.
* Not Required Addenda Timeout You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A Addenda Required. Set the length (in milliseconds) for this timeout by scanning the barcode below, then setting the timeout (from 0-120 milliseconds) by scanning digits from the Programming Chart, beginning on page 311 of this manual, then Save. Default = 500.
If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data. No data is output unless both codes are read. Default = Off. * Off Allow Concatenation Require Concatenation Addenda Timeout You can set a time during which the scanner looks for an addenda.
UPC-E0 UPC-E0 On/Off Most U.P.C. barcodes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 179). Default = On. * UPC-E0 On UPC-E0 Off UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. On * Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E barcodes that have addenda.
Addenda Timeout You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-E0 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the barcode below, then setting the timeout (from 0-120 milliseconds) by scanning digits from the Programming Chart, beginning on page 311 of this manual, then Save. Default = 500.
UPC-E0 Leading Zero This feature allows the transmission of a leading zero (0) at the beginning of scanned data. To prevent transmission, scan Off. Default = On. * On Off UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-E1 Most U.P.C. barcodes lead with the 0 number system. For these codes, use UPC-E0 (page 177).
* UPC-E1 Off EAN/JAN-13 EAN/JAN-13 On/Off * On Off Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A barcodes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A.
EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On Off EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
EAN-13 Beginning with 290 Addenda Required This setting programs the scanner to require a 5 digit addenda only on EAN-13 barcodes that begin with “290.” The following settings can be programmed: Require 5 Digit Addenda: All EAN-13 barcodes that begin with “290” must have a 5 digit addendum. The EAN-13 barcode with the 5 digit addendum is then transmitted as a single, concatenated barcode. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN-13 barcode is discarded.
Default = Don’t Require Addenda. * Don’t Require Addenda Require 2 Digit Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda EAN-13 Beginning with 414/419 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 barcodes that begin with a “414” or “419.
Require 2 or 5 Digit Addenda EAN-13 Beginning with 434/439 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 barcodes that begin with a “434” or “439.” The following settings can be programmed: Require Addenda: All EAN-13 barcodes that begin with a “434” or “439” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda.
Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit Addenda, and you want to disable this feature, scan Don’t Require 2 Digit Addenda. EAN-13 barcodes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 2 Digit Addenda. * Don’t Require 2 Digit Addenda Require 2 Digit Addenda EAN-13 Beginning with 978 Addenda Required These settings program the scanner to require a 5 digit addenda only on EAN-13 barcodes that begin with “978.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 barcodes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 5 Digit Addenda. * Don’t Require 5 Digit Addenda Require 5 Digit Addenda Addenda Timeout You can set a time during which the scanner looks for an addenda.
ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. On * Off EAN/JAN-8 EAN/JAN-8 On/Off * On Off EAN/JAN-8 Check Digit This selection allows you to specify whether or not the check digit should be transmitted at the end of the scanned data. Default = On.
EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 barcodes that have addenda. Default = Not Required. Required * Not Required Addenda Timeout You can set a time during which the scanner looks for an addenda.
setting the timeout (from 0-120 milliseconds) by scanning digits from the Programming Chart, beginning on page 311 of this manual, then Save. Default = 500. Note: The Addenda Timeout setting is applied to all addenda and coupon code searches. Addenda Timeout EAN/JAN-8 Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda. When turned Off, there is no space. Default = On.
MSI Check Character Different types of check characters are used with MSI barcodes. You can program the scanner to read MSI barcodes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI barcodes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
MSI Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On Off GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On Off GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Maximum Message Length Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 159), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media. On * Off Codablock A Codablock A On/Off On * Off If you are reading Code 39 barcodes, Codablock A should remain disabled. If you are enabling Codablock A, you should disable Code 39 (see Code 39 on page 157).
Codablock A Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length Codablock F Codablock F On/Off On * Off If you are reading Code 128 barcodes, Codablock F should remain disabled.
Maximum Message Length Label Code The standard Label Code is used in libraries. Default = Off.
PDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 barcodes. When this selection is enabled, these multiple barcodes are assembled into a single data string.
* Off MicroPDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use.
UPC/EAN Version Scan the UPC/EAN Version On barcode to decode GS1 Composite symbols that have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Version Off. UPC/EAN Version On * UPC/EAN Version Off Note: If you scan coupons that have both UPC and GS1 Databar codes, you may wish to scan and output only the data from the GS1 Databar code. See Coupon GS1 DataBar Output (page 176) for further information.
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPCE expansion is controlled by the UPC-E0 Expand (page 177) setting. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts on page 297). If EAN8 to EAN13 Conversion is scanned, all EAN8 barcodes are converted to EAN13 format. Default = GS1 Emulation Off.
QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR Code. * On Off QR Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089.
Swipe: Pull and hold down the trigger and scan all appended QR Codes while keeping the trigger pressed. The scanner emits short beeps for each partial QR Code that is scanned and buffered. One long beep is emitted after the last QR Code is scanned and the data is complete. Not compatible with Presentation mode. Point and Shoot: Pull the trigger one time for each image. The scanner emits a short beep for each partial QR Code that is scanned and buffered.
DotCode < Default All DotCode Settings > DotCode On/Off On * Off Poor Quality DotCodes This setting improves the scanner’s ability to read damaged or badly printed DotCodes. Default = Poor Quality DotCodes Off. Poor Quality DotCodes On * Poor Quality DotCodes Off DotCode Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-2400. Minimum Default = 1, Maximum Default = 2400.
Digimarc Barcode™ Digimarc Decoder Attempts Set the number of attempts by scanning the barcode below, then setting the number of attempts (0-10) by scanning digits from the Programming Chart beginning on page 311 of this manual, the Save. Minimum to Maximum attempts = 0-10. Default = 3. Digimarc Decoder Attempts Digimarc Barcode This setting programs the scanner to decode Digimarc Barcode using Digimarc and ID decoders.
* Uses Digimarc Decoder then Both Decoders Uses ID Decoder then Alternates Decoders Uses Digimarc Decoder then Alternates Decoders Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Off Direct Part Marking Decoding If you are having trouble reading Direct Part Marking (DPM) barcodes, scan Dotpeen DPM Decoding for Dotpeen codes or scan Reflective (Etched) DPM Decoding for reflective (etched) codes. Default = Disable DPM Decoding.
* Disable DPM Decoding Reflective (Etched) DPM Decoding Data Matrix Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters.
MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off On * Off MaxiCode Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Off Aztec Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
Off Aztec Code Page Aztec Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
Han Xin Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833. Minimum Message Length Maximum Message Length Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time.
Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit, page 212. Postal-4i On Postnet On Also see Postnet Check Digit, page 213.
Postnet and Postal-4i On Postnet and Intelligent Mail Barcode On Postal-4i and Intelligent Mail Barcode On Postal-4i and Postnet with B and B’ Fields On Planet Code and Postnet On Planet Code and Postnet with B and B’ Fields On Planet Code and Postal-4i On Planet Code and Intelligent Mail Barcode Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Barcode On Xenon XP User Guide 211
Planet Code, Postal-4i, and Intelligent Mail Barcode On Postnet, Postal-4i, and Intelligent Mail Barcode On Planet Code, Postal-4i, and Postnet with B and B’ Fields On Planet Code, Intelligent Mail Barcode, and Postnet with B and B’ Fields On Postal-4i, Intelligent Mail Barcode, and Postnet with B and B’ Fields On Planet Code, Postal-4i, Intelligent Mail Barcode, and Postnet On Planet Code, Postal-4i, Intelligent Mail Barcode, and Postnet with B and B’ Fields On Planet Code Check Digit This selection
* Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Australian Post Interpretation This option controls what interpretation is applied to customer fields in Australian 4-State symbols. Bar Output lists the bar patterns in “0123” format. Numeric N Table causes that field to be interpreted as numeric data using the N Table.
Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) China Post (Hong Kong 2 of 5) On/Off On * Off China Post (Hong Kong 2 of 5) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 2-80.
Korea Post Korea Post On * Off Korea Post Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 154) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted or not. Default = Don’t Transmit.
216 Xenon XP User Guide
CHAPTER 9 IMAGING COMMANDS The scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the scanner performs these functions. Note: If you are using the scanner in a stand, you must set the In-Stand Sensor Mode to Off in order to take images (see In-Stand Sensor Mode on page 94).
Image Ship - IMGSHP (page 221) Intelligent Signature Capture - IMGBOX (page 230) The modifiers for each of these commands follow the command description. Note: The images included with each command description are examples only. The results you achieve may be different from those included in this manual. The quality of the output you receive will vary depending on lighting, quality of the initial image/object being captured, and distance of the scanner from the image/object.
B - Beeper Causes a beep to sound after an image is snapped. 0B No beep (default) 1B Sounds a beep when the image is captured. T - Wait for Trigger Waits for a hardware trigger press before taking the image. This is only available when using Photo Style (1P). 0T Takes image immediately (default) 1T Waits for a trigger press, then takes the image L - LED State Determines if the LEDs should be on or off, and when.
G - Gain Gain is used in Manual Style only (2P). Like a volume control, the gain modifier boosts the signal and multiplies the pixel value. As you increase the gain, the noise in an image is also amplified. Example: 1G No gain (default) 2G Medium gain 4G Heavy gain 8G Maximum gain Gain at 1G: Gain at 4G: Gain at 8G: W - Target White Value Sets the target for the median grayscale value in the captured image.
U - Update Tries This sets the maximum number of frames the scanner should take to reach the D Delta for Acceptance. Update Tries is only available when using Photo Style (1P). (Default = 6) nU Range: 0 - 10 % - Target Set Point Percentage Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or below the target white value, and 25% of the pixels are above the target white value.
IMGSHP Modifiers A - Infinity Filter Enhances pictures taken from very long distances (greater than 10 feet or 3m). The Infinity Filter should not be used with IMGSNP Modifiers (page 218). Example: 0A Infinity filter off (default) 1A Infinity filter on Infinity Filter off (0A) from approximately 12 feet (3.66m) away: Infinity Filter on (1A) from approximately 12 feet (3.66m) away: C - Compensation Flattens the image to account for variations in illumination across the image.
E - Edge Sharpen An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the image look cleaner, it also removes some fine detail from the original image. The strength of the edge sharpen filter can be entered from 1 to 24. Entering a 23E gives the sharpest edges, but also increases noise in the image.
H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats. Example: 0H No stretch (default) 1H Histogram stretch Histogram Stretch at 0H: Histogram Stretch at 1H: I - Invert Image Invert image is used to rotate the image around the X or Y axis.
IF- Noise Reduction Used to reduce the salt and pepper noise in an image.
J - JPEG Image Quality Sets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger files. Smaller numbers result in greater amounts of lossy compression, faster transmission times, lower quality, but smaller files.
nB Example: The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 639. (Default = all rows) Uncropped Image: Image Crop set to 300R: Image Crop set to 200B: Image Crop set to 300L: Image Crop set to 200T: Alternately, specify the number of pixels to cut from the outside margin of the image; thus only the center pixels are transmitted.
The smaller number of pixels shipped, the smaller the image, however, after a certain point the image becomes unusable. Example: 1S ship every pixel (default) 2S ship every 2nd pixel, both horizontally and vertically 3S ship every 3rd pixel, both horizontally and vertically Pixel Ship set to 1S: Pixel Ship set to 2S: Pixel Ship set to 3S: Pixel Ship set to 4S: U - Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image.
V - Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image. Example: 0V Don’t blur (default) 1V Blur Blur Image Off (0V): Blur Image On (1V): W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type. A lowkey image has detail concentrated in the shadows; a high-key image has detail concentrated in the highlights; and an average-key image has detail concentrated in the midtones.
* Native Resolution Intelligent Signature Capture - IMGBOX IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a barcode. This allows you to tailor a signature capture area to a specific form. In order to use IMGBOX, you need a set form where the signature box location is in a known location relative to a barcode.
To see this example, align the aimer with the signature area (not with the barcode), then press the trigger. Send the following IMGBOX command string after the trigger press: Example: IMGBOX245w37h55y. Note: Case is not important in the command string. It is used here only for clarity. The following image is captured: The IMGBOX commands have many different modifiers that can be used to change the size and appearance of the signature image output by the scanner.
B - Output Image Height This option is used to size the image vertically. If using this option, set the resolution (R) to zero. Example: Image Height set to 50B: Image Height set to 100B: D - Pixel Depth This indicates the number of bits per pixel in the transmitted image, which defines whether it will be grayscale or black and white.
H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01. In the example, the height of the area to be captured is 3/8 inch, resulting in a value of H = .375/0.01 = 37.5. Example: IMGBOX245w37h55y. K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image.
decimal point between the first and second digit. For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width and B - Output Image Height on page 232). Example: Resolution set to 0R: Resolution set to 1000R: Resolution set to 2000R: S - Barcode Aspect Ratio All dimensions used in IMGBOX are measured as multiples of the minimum element size of the barcode.
Y - Vertical Barcode Offset The vertical barcode offset allows you to offset the vertical center of the signature capture area. Negative numbers indicate that the signature capture is above the barcode, and positive numbers indicate that the area is below the barcode. Measurements are in multiples of the minimum bar width Example: Vertical Offset set to -7Y: .
236 Xenon XP User Guide
CHAPTER 10 UTILITIES To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page 297 for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled. Add Code I.D.
On * Off TotalFreedom TotalFreedom is an open system architecture that makes it possible for you create applications that reside on your scanner. Decoding apps and Data Formatting apps can be created using TotalFreedom. For further information about TotalFreedom, go to our website at www.honeywellaidc.com. Application Plug-Ins (Apps) Any apps that you are using can be turned off or on by scanning the following barcodes. Apps are stored in groups: Decoding, and Formatting.
EZConfig for Scanning Introduction EZConfig for Scanning provides a wide range of PC-based programming functions that can be performed on the scanner connected to your PC. EZConfig for Scanning allows you to download upgrades to the scanner’s firmware, change programmed parameters, and create and print programming barcodes. Using EZConfig for Scanning, you can even save/open the programming parameters.
Reset the Factory Defaults Caution: This selection erases all your settings and resets the scanner to the original factory defaults. It also disables all plugins. If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scanner to factory default settings, first scan the Remove Custom Defaults barcode, then scan Activate Defaults. This resets the scanner to the factory default settings.
CHAPTER 11 SERIAL PROGRAMMING COMMANDS The serial programming commands can be used in place of the programming barcodes. Both the serial commands and the programming barcodes will program the scanner. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual. The device must be set to an RS232 interface (see page 16). The following commands can be sent via a PC COM port using terminal emulation software.
scanner. This setting is changed by using the BT_NAM command, which accepts alphanumeric values. If the name is not known, a wildcard (*) can be used :* Note: Since the base stores all work group settings and transfers to them to scanner once they are linked, changes are typically done to the base and not to the scanner. Tag A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS232 configuration settings are identified with a Tag of 232.
SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence.
This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?.
The scanner scans until a barcode has been read, until the deactivate command is sent, or until the serial time-out has been reached (see Read Time-Out on page 91 for a description, and the serial command on page 256). Reset the Custom Defaults If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults barcode below. This resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default settings.
Menu Commands Setting * Indicates default Serial Command # Indicates a numeric entry Page Set Custom Defaults MNUCDP 13 Save Custom Defaults MNUCDS 13 Reset the Custom Defaults Activate Custom Defaults DEFALT 13 Reset the Factory Defaults cordless scanners Factory Default Settings: All Application Groups PAPDFT& 72 Reset the Custom Defaults cordless scanners Custom Default Settings: All Application Groups PAPDFT 73 Keyboard Wedge: IBM PC AT and Compatibles with CR suffix PAP_AT 15 La
Selection Program Keyboard Country Xenon XP User Guide Setting * Indicates default Serial Command # Indicates a numeric entry Page Wincor Nixdorf RS232 Mode A PAPWMA 22 *U.S.A.
Selection 248 Setting * Indicates default Serial Command # Indicates a numeric entry Page Hungarian (101 key) KBDCTY50 25 Hungary KBDCTY19 25 Iceland KBDCTY75 25 Irish KBDCTY73 25 Italian (142) KBDCTY56 26 Italy KBDCTY5 26 Japan ASCII KBDCTY28 26 Kazakh KBDCTY78 26 Kyrgyz (Cyrillic) KBDCTY79 26 Latin America KBDCTY14 26 Latvia KBDCTY42 26 Latvia (QWERTY) KBDCTY43 26 Lithuania KBDCTY44 26 Lithuania (IBM) KBDCTY45 26 Macedonia KBDCTY34 26 Malta KBDCTY74 26
Selection ALT Mode Keyboard Style Keyboard Conversion Control Character Output Xenon XP User Guide Setting * Indicates default Serial Command # Indicates a numeric entry Page Switzerland (German) KBDCTY6 28 Tatar KBDCTY85 28 Turkey F KBDCTY27 28 Turkey Q KBDCTY24 29 Ukrainian KBDCTY76 29 United Kingdom KBDCTY7 29 United Stated (Dvorak right) KBDCTY89 29 United States (Dvorak left) KBDCTY88 29 United States (Dvorak) KBDCTY87 29 United States (International) KBDCTY30 29
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Keyboard Modifiers *Control + X Off KBDCAS0 33 DOS Mode Control + X KBDCAS1 33 Windows Mode Control + X KBDCAS2 33 Windows Mode Prefix/Suffix Off KBDCAS3 33 DOS Mode Control + X Mode On with Windows Mode Prefix/Suffix KBDCAS4 33 Supports ALT 3 Digit HEX Mode KBDCAS5 33 *Turbo Mode Off KBDTMD0 33 Turbo Mode On KBDTMD1 33 *Numeric Keypad Off KBDNPS0 33 Numeric Keypad On KBDNPS1 33 *Auto Dir
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page RS232 Handshaking *RTS/CTS Off 232CTS0 37 Flow Control, No Timeout 232CTS1 37 Two-Direction Flow Control 232CTS2 37 Flow Control with Timeout 232CTS3 37 RS232 Timeout (1-5100 milliseconds) 232DEL#### 37 *XON/XOFF Off 232XON0 38 XON/XOFF On 232XON1 37 *ACK/NAK Off 232ACK0 38 ACK/NAK On 232ACK1 38 *Packet Mode Off 232PKT0 38 Packet Mode On 232PKT2 38 *Bioptic ACK/NAK Off 232NAK0 39 Bi
Serial Command # Indicates a numeric entry Page Scan in Cradle Off (CCB-H-010BT default) BT_SIC0 53 Scan in Cradle On (CCB01-010BT default) BT_SIC1 53 Shut Down Scanner in Cradle BT_SIC2 53 Base Charge Off BTRCHG0 54 *External or Interface Cable Power BTRCHG1 54 External Power Only BTRCHG2 54 *On BEPPGE1 54 Off BEPPGE0 54 *Low (1000 Hz) BEPPFQ1000 55 Medium (3250 Hz) BEPPFQ3250 55 High (4200 Hz) BEPPFQ4200 55 *Low/Razz (250 Hz) (min 200 Hz) BASFQ2250 55 Medium (3250 Hz)
Setting * Indicates default Serial Command # Indicates a numeric entry Page *Full Power (100%) BT_TXP100 62 Medium Power (35%) BT_TXP35 62 Medium Low Power (5%) BT_TXP5 62 Low Power (1%) BT_TXP1 62 *Full Power (100%) BT_TXP8 63 Medium High Power (87%) BT_TXP7 63 Medium Power (50%) BT_TXP4 63 Low Power (1%) BT_TXP1 63 Automatic Batch Mode BATENA1 64 *Batch Mode Off BATENA0 64 Inventory Batch Mode BATENA2 64 Persistent Batch Mode BATENA3 64 Off BATBEP0 64 *On BATBEP1
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Batch Mode Transmit Delay *Off (No Delay) BATDLY0 69 Short (250 ms) BATDLY250 69 Medium (500 ms) BATDLY500 69 Long (1000 ms) BATDLY1000 69 Multiple Scanner Operation Multiple Scanner Operation BASCON2,DNG3 69 Scanner Name 0001 BT_NAM0001 70 0002 BT_NAM0002 70 0003 BT_NAM0003 70 0004 BT_NAM0004 70 0005 BT_NAM0005 70 0006 BT_NAM0006 70 0007 BT_NAM0007 70 Reset RESET_ 71 Scanner N
Setting * Indicates default Serial Command # Indicates a numeric entry Page Change the Scanner’s Bluetooth PIN Code Bluetooth PIN Code BT_PIN 77 Auto Reconnect Mode *Auto Reconnect On BT_ACM1 77 Auto Reconnect Off BT_ACM0 77 Maximum Link Attempts Maximum Link Attempts (0-100) *0 BT_MLA### 78 Relink Time-Out Relink Time-Out (1-100) *3 BT_RLT### 79 Host Command Acknowledgment Host ACK On HSTACK1 81 *Host ACK Off HSTACK0 81 Host ACK Timeout (1-90) *10 HSTATO## 82 Power Up Beeper
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Beeper Duration - Good Read *Normal Beep BEPBIP0 87 Short Beep BEPBIP1 87 Off BEPLED0 87 *On BEPLED1 87 Number of Beeps - Good Read (Range 1 - 9) *1 BEPRPT# 87 Number of Beeps - Error (Range 1 - 9) *1 BEPERR# 87 Good Read Delay *No Delay DLYGRD0 88 Short Delay (500 ms) DLYGRD500 88 Medium Delay (1000 ms) DLYGRD1000 88 Long Delay (1500 ms) DLYGRD1500 88 User-Specified Good Read Delay R
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page In-Stand Sensor Mode *Sensor On TRGSSW1 94 Sensor Off TRGSSW0 94 Poor Quality 1D Reading On DECLDI1 94 *Poor Quality 1D Reading Off DECLDI0 95 *Poor Quality PDF Reading On PDFXPR10 94 Poor Quality PDF Reading Off PDFXPR0 95 Low Resolution PDF Codes On PDFDMI1 95 *Low Resolution PDF Codes Off PDFDMI0 95 *CodeGate Off Out-of-Stand AOSCGD0. 96 CodeGate On Out-of-Stand AOSCGD1.
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Illumination Lights *Lights On SCNLED1 101 Lights Off SCNLED0 101 1 millisecond SCNDLY1 101 250 milliseconds SCNDLY250 101 500 milliseconds SCNDLY500 101 *Off (no delay) SCNDLY0 101 User-Specified Aimer Delay Range 0 - 4,000 ms SCNDLY#### 102 Aimer Mode Off SCNAIM0 102 *Interlaced SCNAIM2 102 Single Code Centering Single Code Centering DECWIN1;DECTOP49;DECBOT 51;DECRGT51;DECLFT49 103 C
Selection Require Output Sequence Good Read Tone - Output Sequences Multiple Symbols No Read Video Reverse Working Orientation Setting * Indicates default Serial Command # Indicates a numeric entry Page Terminate String FF 107 Define Satisfactory Subsets SEQSAT 107 Timeout for SEQSAT SEQTIM 107 *Discard Partial Output Sequence SEQTTS0 112 Default Output Sequence SEQDFT 113 Required SEQ_EN2 114 On/Not Required SEQ_EN1 114 *Off SEQ_EN0 114 Good Read Beep - Each Code in Sequen
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Silent Mode with Long LED Corded Scanner beplfn0;beplfr10;beppwr0;beplv l0;bepbip0;bepFQ12700;beplot 1. 120 Very Low Beeper (Nighttime Mode) - Cordless Scanner and Base beplfn0;beplfr10;beppar0;basp wr0;beppwr1;baslvl1;beplvl1;be pbip1;bepFQ14200;beplot0. 120 Very Low Beeper (Nighttime Mode) - Corded Scanner beplfn0;beplfr10;beppwr1;beplv l1;bepbip1;bepFQ14200;beplot 0.
Setting * Indicates default Serial Command # Indicates a numeric entry Page Scanner Alarm Volume High BT_ORV3 125 Out-of-Range Delay (Range 03000) *0 BT_ORY#### 125 VSUFCR 129 Add Prefix PREBK2## 129 Clear One Prefix PRECL2 129 Clear All Prefixes PRECA2 129 Add Suffix SUFBK2## 129 Clear One Suffix SUFCL2 129 Clear All Suffixes SUFCA2 129 *Enable RMVFNC0 130 Disable RMVFNC1 130 Intercharacter Delay Range 0 - 5000 (5ms increments) DLYCHR#### 130 User Specified Interchara
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Primary/Alternate Data Formats Primary Data Format ALTFNM0 151 Data Format 1 ALTFNM1 151 Data Format 2 ALTFNM2 151 Data Format 3 ALTFNM3 151 Single Scan-Primary Data Format VSAF_0 151 Single Scan-Data Format 1 VSAF_1 152 Single Scan-Data Format 2 VSAF_2 152 Single Scan-Data Format 3 VSAF_3 152 All Symbologies All Symbologies Off ALLENA0 154 Codabar Default All Codabar Settings CBRDFT 154
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Code 39 Append *Off C39APP0 158 On C39APP1 158 *Off C39B320 159 On C39B321 159 *Off C39ASC0 159 On C39ASC1 159 Code 39 Code Page C39DCP 159 Default All Interleaved 2 of 5 Settings I25DFT 160 Off I25ENA0 160 *On I25ENA1 160 *No Check Digit I25CK20 160 Validate, But Don’t Transmit I25CK21 160 Validate and Transmit I25CK22 160 Minimum (2 - 80) *4 I25MIN## 161 Maximum (2 - 80) *80
Serial Command # Indicates a numeric entry Page Default All Straight 2 of 5 Industrial Settings R25DFT 165 *Off R25ENA0 165 On R25ENA1 165 Straight 2 of 5 Industrial Message Length Minimum (1 - 48) *4 R25MIN## 165 Maximum (1 - 48) *48 R25MAX## 165 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA Settings A25DFT 166 Straight 2 of 5 IATA *Off A25ENA0 166 On A25ENA1 166 Straight 2 of 5 IATA Redundancy Range (0 - 10) *0 A25VOT## 166 Straight 2 of 5 IATA Message Length Mini
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page GS1-128 Default All GS1-128 Settings GS1DFT 171 *On GS1ENA1 171 Off GS1ENA0 171 Minimum (1 - 80) *1 GS1MIN## 171 Maximum (0 - 80) *80 GS1MAX## 171 Default All Telepen Settings TELDFT 172 *Off TELENA0 172 On TELENA1 172 *AIM Telepen Output TELOLD0 172 Original Telepen Output TELOLD1 172 Minimum (1 - 60) *1 TELMIN## 172 Maximum (1 - 60) *60 TELMAX## 172 Default All UPC-A Settings UPA
Serial Command # Indicates a numeric entry Page Default All UPC-E Settings UPEDFT 177 Off UPEEN00 177 *On UPEEN01 177 *Off UPEEXP0 177 On UPEEXP1 177 Required UPEARQ1 177 *Not Required UPEARQ0 177 Addenda Timeout Range (0 - 120) *500 DLYADD##### 178 UPC-E0 Addenda Separator *On UPEADS1 178 Off UPEADS0 178 Off UPECKX0 178 *On UPECKX1 178 Off UPENSX0 179 *On UPENSX1 179 2 Digit Addenda On UPEAD21 179 *2 Digit Addenda Off UPEAD20 179 5 Digit Addenda On UPEAD
Setting * Indicates default Serial Command # Indicates a numeric entry Page *Don’t Require Addenda ARQ3780 182 Require 2 Digit Addenda ARQ3781 182 Require 5 Digit Addenda ARQ3782 182 Require 2 or 5 Digit Addenda ARQ3783 182 *Don’t Require Addenda ARQ4140 183 Require 2 Digit Addenda ARQ4141 183 Require 5 Digit Addenda ARQ4142 183 Require 2 or 5 Digit Addenda ARQ4143 183 *Don’t Require Addenda ARQ4340 184 Require 2 Digit Addenda ARQ4341 184 Require 5 Digit Addenda ARQ4342 18
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page MSI Default All MSI Settings MSIDFT 189 *Off MSIENA0 189 On MSIENA1 189 *Validate Type 10, but Don’t Transmit MSICHK0 190 Validate Type 10 and Transmit MSICHK1 190 Validate 2 Type 10 Chars, but Don’t Transmit MSICHK2 190 Validate 2 Type 10 Chars and Transmit MSICHK3 190 Validate Type 11 then Type 10 Char, but Don’t Transmit MSICHK4 190 Validate Type 11 then Type 10 Char and Transmit MSICHK5 1
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Codablock F Default All Codablock F Settings CBFDFT 194 *Off CBFENA0 194 On CBFENA1 194 Minimum (1 - 2048) *1 CBFMIN#### 194 Maximum (1 - 2048) *2048 CBFMAX#### 194 On LBLENA1 195 *Off LBLENA0 195 Default All PDF417 Settings PDFDFT 195 *On PDFENA1 195 Off PDFENA0 195 Minimum (1-2750) *1 PDFMIN#### 196 Maximum (1-2750) *2750 PDFMAX#### 196 *On PDFMAC1 196 Off PDFMAC0 196 Defaul
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page QR Code Append *One Scan QRCAPP1 200 Swipe QRCAPP2 200 Point & Shoot QRCAPP3 200 Off QRCAPP0 200 QR Code Page QR Code Page (*3) QRCDCP## 201 DotCode Default All DotCode Settings DOTDFT 202 On DOTENA1 202 *Off DOTENA0 202 Poor Quality DotCodes On DOTEXS1 202 *Poor Quality DotCodes Off DOTEXS0 202 Minimum (1- 2400) *1 DOTMIN#### 202 Maximum (1- 2400) *2400 DOTMAX#### 202 Decoder Att
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Aztec Code Default All Aztec Code Settings AZTDFT 207 *On AZTENA1 207 Off AZTENA0 207 Minimum (1-3832) *1 AZTMIN#### 207 Maximum (1-3832) *3832 AZTMAX#### 207 *On AZTAPP1 207 Off AZTAPP0 207 Aztec Code Page Aztec Code Page (*51) AZTDCP## 208 Chinese Sensible (Han Xin) Code Default All Han Xin Code Settings HX_DFT 208 On HX_ENA1 208 *Off HX_ENA0 208 Minimum (1-7833) *1 HX_MIN#### 20
Setting * Indicates default Serial Command # Indicates a numeric entry Page Planet and Postal-4i On POSTAL13 211 Planet and Intelligent Mail Barcode On POSTAL15 211 Planet, Postnet, and Postal-4i On POSTAL21 211 Planet, Postnet, and Intelligent Mail Barcode On POSTAL22 211 Planet, Postal-4i, and Intelligent Mail Barcode On POSTAL23 212 Postnet, Postal-4i, and Intelligent Mail Barcode On POSTAL24 212 Planet, Postal-4i, and Postnet with B and B’ Fields On POSTAL25 212 Planet, Intellige
Selection Setting * Indicates default Serial Command # Indicates a numeric entry Page Korea Post Msg.
Selection 274 Serial Command # Indicates a numeric entry Page File Format - TIFF binary group 4, compressed IMGFMT2 223 File Format - TIFF grayscale IMGFMT3 223 File Format - Uncompressed binary IMGFMT4 223 File Format - Uncompressed grayscale IMGFMT5 223 File Format - BMP IMGFMT8 223 *Histogram Stretch Off IMGHIS0 224 Histogram Stretch On IMGHIS1 224 *Noise Reduction Off IMGFSP0 225 Noise Reduction On IMGFSP1 225 Invert Image around X axis IMGNVX1 224 Invert Image around Y
Setting * Indicates default Serial Command # Indicates a numeric entry Page Ship Histogram IMGHST1 229 Force VGA Resolution IMGVGA1 229 *Native Resolution IMGVGA0 230 Optimize On DECBND1 230 *Optimize Off DECBND0 230 Add Code I.D.
276 Xenon XP User Guide
CHAPTER 12 PRODUCT SPECIFICATIONS Xenon XP 1950g/1950h Corded Scanner Product Specifications Parameter Specification Mechanical Height 6.5 inches (165mm) Length 3.9 inches (99mm) Width 2.5 inches (64mm) Weight General Duty Healthcare 5.3 ounces (150g) 5.5 ounces (155g) Electrical Voltage Requirements 4.4 to 5.5 VDC at input connector Current Draw ScanningStandby 500mA @ 5VDC, 2.
Parameter (Continued) Specification Mechanical Drop Operational after 50 drops from 6 feet (1.8m) to concrete ESD Tolerance Up to 15kV direct air Up to 8 kV indirect coupling plane Sealant Rating IP42 Image Image Size 1280 x 800 pixels Scan Performance Skew Angle +65° Pitch Angle 1D barcode 2D barcode 1D code: +65° 2D code: +45° Motion Tolerance Up to 4.
Parameter (Continued) Specification Battery Lithium Ion Number of Scans 2400 mAHr minimum Up to 50,000 per charge Expected Hours of Operation 14 Expected Charge Time 4.5 hours Radio Frequency 2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v 4.2 Range 33 ft.
Xenon XP 1952g-BF/1952h-BF Scanner Product Specifications Parameter Specification Mechanical Height 6.5 inches (165mm) Length 3.9 inches (99mm) Width 2.5 inches (64mm) Weight General Duty Healthcare 6.9 ounces (195g) 7.1 ounces (201g) Use Time # of Scans per full charge 450 scans @ 1 scan per second Expected Minutes of Operation 25 minutes @ 5 scans per minute Electrical Current Draw Operating Power (Charging) 500mA @ 5VDC, 2.
Parameter (Continued) Specification Scan Performance Skew Angle +65° Pitch Angle 1D barcode 2D barcode 1D barcodes: +65° 2D barcodes: +45° Motion Tolerance Up to 4.0 m/s (157 in/s) for 13 mil UPC at optimal focus Symbol Contrast 20% or greater (Grade A) CCB01-010BT/CCB01-010BT-BF Charge Base Product Specifications Parameter Specification Mechanical Height 3.2 inches (81.3mm) Length 5.19 inches (131.8mm) Width 3.98 inches (101.1mm) Weight 6.3 oz (179g) Electrical Voltage: 4.5 to 5.
Parameter (Continued) Specification Sealant Rating IP41 CCB-H-010BT/CCB-H-010BT-BF Charge Base Product Specifications Parameter Specification Mechanical Height 3.3 inches (83mm) Length 9.1 inches (231mm) Width 3.5 inches (89mm) Weight 9.2 oz (260g) Electrical Voltage: 4 to 5.
Depth of Field Charts 1950g/1952g/1952g-BF Typical Performance Focus Standard Range High Density Symbology Near Distance Near Distance 5 mil Code 39 13 mil UPC 20 mil Code 39 6.7 mil PDF417 10 mil Data Matrix 20 mil QR Code Far Distance Far Distance mm 28 242 14 219 in. 1.1 9.5 0.6 8.6 mm 0 490 0 368 in. 0 19.3 0 14.5 mm 4 822 6 604 in. 0.1 32.4 0.2 23.8 mm 34 220 17 211 in. 1.4 8.7 1.4 8.3 mm 29 245 12 211 in. 1.1 9.7 1.1 8.
Focus (Continued) Standard Range High Density Symbology (Continued) Near Distance Near Distance 20 mil QR Code Far Distance Far Distance mm 21 351 23 290 in. 0.8 13.8 0.9 11.4 1950h/1952h/1952h-BF Typical Performance Focus Standard Range High Density Symbology Near Distance Near Distance 5 mil Code 39 13 mil UPC 20 mil Code 39 6.7 mil PDF417 10 mil Data Matrix 20 mil QR Code Far Distance Far Distance mm 28 253 16 219 in. 1.1 10 0.6 8.6 mm 0 495 0 366 in.
Focus (Continued) Standard Range High Density Symbology (Continued) Near Distance Near Distance 6.7 mil PDF417 10 mil Data Matrix 20 mil QR Code Far Distance Far Distance mm 49 208 24 200 in. 1.9 8.2 0.9 7.9 mm 46 233 18 194 in. 1.8 9.2 0.7 7.6 mm 15 373 13 259 in. 0.6 14.7 0.5 10.2 Standard Connector Pinouts Note: The following pin assignments are not compatible with some Honeywell legacy products.
Serial Output 10 Pin RJ41 Modular Plug - connects to the base 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data 5 Receive data - serial data to scanner 6 CTS 7 +5V power 8 RTS 9 10 RS485 Output 10 Pin RJ41 Modular Plug - connects to the base Note: RS485 signal conversion is performed in the cable.
USB 10 Pin Modular Plug - connects to the base 1 Cable shield 2 Cable select 3 Supply ground 4 5 6 7 +5V power 8 9 Data + 10 Data - Xenon XP User Guide 287
Required Safety Labels Scanner Illumination output Part Number, Serial Number and Revision Information location 288 Compliance Label location Xenon XP User Guide
CCB01-010BT/CCB01-010BT-BF Base Part Number, Serial Number and Revision Information location Xenon XP User Guide Compliance Label locations 289
CCB-H-010BT/CCB-H-010BT-BF Base Compliance label locations 290 Xenon XP User Guide
CHAPTER 13 MAINTENANCE AND TROUBLESHOOTING Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center (see Customer Support on page xvii). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following sections describe periodic checks to ensure dependable operation.
Clean the Window Reading performance may degrade if the scanner’s window is not clean. If the window is visibly dirty, or if the scanner isn’t operating well, clean the window with soft cloth dampened with water. Caution: Do not use abrasive wipes or cloths on the scanner’s window. Abrasive wipes may scratch the window. Never use solvents (e.g., acetone) on the window. Solvents may damage the window.
Replace an Interface Cable 1. Turn off the power to the host system. 2. Disconnect the scanner’s cable from the terminal or computer. 3. Locate the small hole on the back of the scanner’s handle. This is the cable release. 4. Straighten one end of a paper clip. 5. Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out while maintaining pressure on the paper Cable clip, then remove the paper clip. Release 6.
5. Replace with the new cable. Insert the connector into the opening and press firmly. The connector is keyed to go in only one way, and will click into place. Change a Scanner Battery 1. Grasp the wing connector or use a Phillips head screwdriver to remove the screw from the end cap. 2. Remove the end cap and remove the battery from the handle. 3. Insert replacement battery. 4. Replace end cap and screw together.
into your application. Refer to Prefix/Suffix Overview on page 127 for further information. If you aren’t sure what programming options have been set in the scanner, or if you want the factory default settings restored, refer to Reset the Factory Defaults on page 240. Troubleshoot a Cordless System Troubleshoot a Base Note: Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for both the scanner and the base.
• Are enabled in the base or Access Point to which the scanner connects. Is the barcode displayed but not entered into the application? The barcode is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example). • You need to program a suffix. Programming a suffix enables the scanner to output the barcode data plus the key you need (such as “CR”) to enter the data into your application.
APPENDIX A REFERENCE CHARTS Symbology Charts Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Edit beginning on page 127 and Data Format beginning on page 133 for information about using Code ID and AIM ID.
AIM Linear Symbology EAN-8 with Add-On ID Honeywell Possible modifiers (m) ]E3 ID Hex D 44 y 79 GS1 GS1 DataBar ]em GS1 DataBar Limited ]em { 7B GS1 DataBar Expanded ]em } 7D GS1-128 ]C1 I 49 China Post (Hong Kong 2 of 5) ]X0 Q 51 Interleaved 2 of 5 ]Im e 65 Matrix 2 of 5 ]X0 m 6D NEC 2 of 5 ]X0 Y 59 Straight 2 of 5 IATA ]Rm f 66 Straight 2 of 5 Industrial ]S0 f 66 g 67 t 74 0 2 of 5 MSI ]Mm Telepen ]Bm UPC 0, 1, 3 0, 1, 3 0, 1 0, 1, 2, 3, 8, 9,
AIM 2D Symbology ID Chinese Sensible Code (Han Xin Code) ]X0 Codablock A ]O6 Codablock F Honeywell Possible modifiers (m) ID Hex H 48 0, 1, 4, 5, 6 V 56 ]Om 0, 1, 4, 5, 6 q 71 Code 49 ]Tm 0, 1, 2, 4 l 6C Data Matrix ]dm 0-6 w 77 Dot Code ]J0 .
ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X function is OS and application dependent. The following table lists some commonly used Microsoft functionality. This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings.
Lower ASCII Reference Table Note: Windows Code page 1252 and lower ASCII use the same characters. Printable Characters DEC HEX Character 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F ! " # $ % & ' ( ) * + , .
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII Alternate Extended 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 302 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 Œ Ž ‘ ’ “ ” • – — ˜ ™ š › œ ž Ÿ ¡ ¢ £ ¤ ¥ ¦ § ¨
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII Alternate Extended 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 Xenon XP User Guide C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Ð Ñ
Extended ASCII Characters (Continued) DEC HEX CP 1252 ASCII Alternate Extended 248 249 250 251 252 253 254 255 F8 F9 FA FB FC FD FE FF ø ù ú û ü ý þ ÿ PS2 Scan Code ° ∙ · √ ⁿ ² ■ ISO 2022/ISO 646 Character Replacements Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
Standard Keyboard Country Honeywell Code Page Option Spain ISO/IEC 646-17 10 90 Spain ISO/IEC 646-85 51 91 Code Page Selection Method/ Country Xenon XP User Guide 305
64 91 92 93 94 96 123 124 125 126 Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E US 0 1 # $ @ [ \ ] ^ ` { | } ~ CA 54 95 # $ à â ç ê î ô é ù è û CA 18 96 # $ à â ç ê É ô é ù è û JP 28 98 # $ @ [ ¥ ] ^ ` { | } ‾ CN 92 99 # ¥ @ [ \ ] ^ ` { | } ‾ GB 7 87 £ $ @ [ \ ] ^ ` { | } ˜ FR 3 83 £ $ à ° ç § ^ µ é ù è ¨ DE 4 84 # $ § Ä Ö Ü ^ ` ä ö ü ß CH 6 86 ù $ à é ç ê î ô ä
Keyboard Key References 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2B 4B 50 55 4C 51 56 2C 2E 2F 30 31 32 33 34 35 36 37 39 3D 3A 3B 3C 3E 3F 38 40 53 4F 54 59 5A 5F 5B 60 5C 61 5D 62 63 64 69 65 6A 66 67 6C 68 5A 5F 5B 60 5C 61 5D 62 63 64 69 65 6A 66 67 6C 68 104 Key U.S.
308 Xenon XP User Guide
SAMPLE SYMBOLS UPC-A Interleaved 2 of 5 0 123456 7890 01234567890 EAN-13 9 780330 290951 Code 128 Code 39 Code 128 BC321 Codabar A13579B Code 93 Straight 2 of 5 Industrial 123456-9$ 123456 Matrix 2 of 5 6543210 RSS-14 PDF417 (01) 00123456789012 Car Registration Code 49 1234567890 Xenon XP User Guide 309
SAMPLE SYMBOLS (CONTINUED) Postnet Data Matrix Zip Code Test Symbol QR Code Numbers MaxiCode Micro PDF417 Test Message Test Message DotCode 12345 310 Xenon XP User Guide
PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 Xenon XP User Guide 311
PROGRAMMING CHART (CONTINUED) A B C D E F Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Honeywell 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.