User's Manual
Table Of Contents
- Xenon™ 1900/1902
- User’s Guide
- Table of Contents
- Getting Started
- Programming the Interface
- Introduction
- Programming the Interface - Plug and Play
- Keyboard Wedge
- Laptop Direct Connect
- RS232 Serial Port
- RS485
- RS485 Packet Mode
- USB IBM SurePos
- USB PC or Macintosh Keyboard
- USB HID
- USB Serial
- Verifone® Ruby Terminal Default Settings
- Gilbarco® Terminal Default Settings
- Honeywell Bioptic Aux Port Configuration
- Datalogic™ Magellan© Bioptic Aux Port Configuration
- NCR Bioptic Aux Port Configuration
- Wincor Nixdorf Terminal Default Settings
- Wincor Nixdorf Beetle™ Terminal Default Settings
- Keyboard Country Layout
- Keyboard Style
- Keyboard Conversion
- Control Character Output
- Keyboard Modifiers
- RS232 Baud Rate
- RS232 Word Length: Data Bits, Stop Bits, and Parity
- RS232 Receiver Time-Out
- RS232 Handshaking
- Scanner to Bioptic Communication
- Cordless System Operation
- How the Cordless Base Works
- Linking the Scanner to the Base
- Communication Between the Cordless System and the Host
- RF (Radio Frequency) Module Operation
- System Conditions
- Page Button
- About the Battery
- Beeper and LED Sequences and Meaning
- Reset Scanner
- Scanning while in Base Cradle
- Paging
- Error Indicators
- Scanner Report
- Scanner Address
- Base Address
- Single Scanner Modes
- Unlinking the Scanner
- Out-of-Range Alarm
- Flexible Power Management
- Batch Mode
- Multiple Scanner Operation
- Scanner Name
- Application Work Groups
- Resetting the Factory Defaults: All Application Work Groups
- Resetting the Custom Defaults: All Application Work Groups
- Using the Scanner with Bluetooth Devices
- Minimizing Bluetooth/ISM Band Network Activity
- Host Command Acknowledgment
- Input/Output Settings
- Power Up Beeper
- Beep on BEL Character
- Trigger Click
- Good Read and Error Indicators
- Manual/Serial Trigger Modes
- In-Stand Sensor Mode
- Presentation Mode
- Streaming Presentation™ Mode
- Mobile Phone Read Mode
- Image Snap and Ship
- Hands Free Time-Out
- Reread Delay
- User-Specified Reread Delay
- Illumination Lights
- Aimer Delay
- Scanner Time-Out
- Aimer Mode
- Centering
- Preferred Symbology
- Output Sequence Overview
- Multiple Symbols
- No Read
- Video Reverse
- Data Editing
- Data Formatting
- Symbologies
- All Symbologies
- Message Length Description
- Codabar
- Code 39
- Interleaved 2 of 5
- NEC 2 of 5
- Code 93
- Straight 2 of 5 Industrial (three-bar start/stop)
- Straight 2 of 5 IATA (two-bar start/stop)
- Matrix 2 of 5
- Code 11
- Code 128
- GS1-128
- Telepen
- UPC-A
- UPC-A/EAN-13 with Extended Coupon Code
- UPC-E0
- UPC-E1
- EAN/JAN-13
- EAN/JAN-8
- MSI
- GS1 DataBar Omnidirectional
- GS1 DataBar Limited
- GS1 DataBar Expanded
- Trioptic Code
- Codablock A
- Codablock F
- PDF417
- MicroPDF417
- GS1 Composite Codes
- GS1 Emulation
- TCIF Linked Code 39 (TLC39)
- QR Code
- Data Matrix
- MaxiCode
- Aztec Code
- Chinese Sensible (Han Xin) Code
- Postal Codes - 2D
- Postal Codes - Linear
- Imaging Commands
- Interface Keys
- Utilities
- Serial Programming Commands
- Product Specifications
- Maintenance
- Customer Support
- Reference Charts
- Sample Symbols
- Programming Chart
3 - 28
Scan the Relink Time-Out bar code, then scan the number of seconds for
the setting (from 1-100) from the inside back cover. Scan Save to save the
setting.
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to
connect to base unit. Each attempt consists of approximately 5 seconds of
active time followed by 3 seconds of idle time. After one hour, the scanner
powers off and batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, 15 attempts are made to link to the
base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the scanner stops trying to connect to the base unit, but retains
any bar codes that may have been saved in batch mode. After one hour,
the scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, no action is taken to re-link. When
the trigger is pulled, 15 attempts are made to link to the base unit. Each
attempt consists of approximately 5 seconds of active time followed by 3
seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the
scanner stops trying to connect to the base unit, but retains any bar codes
that may have been saved in batch mode. After one hour, the scanner
powers off and batch mode data is lost. Refer to Auto Reconnect
Mode, page 3-26, to review other events that can start the re-link process.
Auto Reconnect Mode set to 1
Maximum Link Attempts set to 0
Relink Time-Out set to 10
Scanner Power Time-Out Timer set to 1800
Note: See Scanner Power Time-Out Timer on page 4-7.
The scanner attempts to connect to the base unit every 15 seconds, mea-
sured from start of attempt to start of attempt. After one half hour, the
scanner powers off.
Relink Time-Out
Preliminary Draft