Perfect Water Technologies Home Master® Reverse Osmosis System Installation & Service Manual Home Home Home Home Home Master® Master® Master® Master® Master® Standard RO Full Contact® Artesian IRON ULTRA HydroPerfection® ***Please register your warranty*** www.theperfectwater.com/warranty-registration.html Scan this 3D barcode with your smartphone to register your warranty.
Home Master® Reverse Osmosis System—Owners Manual Home Master® RO Contents: 1 1 1 1 1 1 1 1 Assembled RO filter cluster Storage tank Tank valve Drain saddle & gasket Roll Teflon tape Mounting clip & screw Chrome long reach RO faucet (or custom choice); faucet adapter and hardware. EZ adapter—feed water adapter 3/8” mc x 3/8” fc x 3/8” tube General System Specifications • • • • • • Feed water: PSI 40 - 100 PSI Feed water Temperature: 40˚ - 100˚(F) Max. Total Dissolved Solids (TDS): 1500 ppm Max.
Home Master® Reverse Osmosis System—Owners Manual ½” masonry drill bit (not required if sink has a pre-drilled hole, or if sink is not porcelain) Drilling hole for RO faucet – porcelain sinks steps 1-5; stainless sinks steps 3-5 WARNING: Serious cracking and damage may occur to your sink even if instructions are followed exactly due to age and the imperfections inherent in natural materials. Instructions may not apply exactly to your sink. Use caution – sink may be slippery. 1.
Home Master® Reverse Osmosis System—Owners Manual adapter as outlined later. Installing The Home Master® Reverse Osmosis System 1. Mount RO Faucet* 1. Use existing hole, or drill 1/2” hole in sink top. See page 3. 2. Slide small rubber washer onto faucet shank, then metal escutcheon plate. 3. Slide rubber washer onto faucet shank. 4. Insert shank through hole in sink. 5. Slide locating washer, followed by locking washer onto shank under sink. 6.
Home Master® Reverse Osmosis System—Owners Manual 3. Install drain saddle clamp – Identify a vertical section of drainpipe with enough space to mount the drain saddle clamp. NOTE: A horizontal section of pipe can be used provided the drain saddle opening flows downward into the pipe, like a manhole drops down into the sewer. DO NOT mount the drain saddle between the P-trap and the wall. The drain pipe material can be either metal or plastic.
Home Master® Reverse Osmosis System—Owners Manual the lower cabinetry, high along the back wall just below the drawers. Make sure cabinet contents are removed, prior to drilling, and ¼” tubing does not come into contact with drawers, doors, or sharp objects. Smooth the holes free from splinters and sharp edges.
Home Master® Reverse Osmosis System—Owners Manual B) RO Faucet: Insert BLUE 3/8” tubing into RO faucet adapter. Push tubing all the way in, then pull back gently to check fit. Push twice to be sure its really in. C) Reserve tank- Insert BLACK 3/8” tubing into the tank shut off valve. Push tubing all the way in, then pull back gently to check fit. D) Drain — Locate the black plastic nut found in drain saddle parts bag. Press it onto the RED 1/4” tubing attached to the filter cluster.
Home Master® Reverse Osmosis System—Owners Manual Troubleshooting IMPORTANT NOTE: Before performing service on the Home Master® RO at any time, and for any reason: first close all under-sink water valves, except for the RO faucet, which you should open to relieve system pressure and drain away excess water from the lines. Pushpull and quick connect fittings are nearly impossible to remove when under pressure. Leaks from metal fittings Unscrew fittings and re-tape male fitting.
Home Master® Reverse Osmosis System—Owners Manual Weak pressure at RO faucet & Reserve tank filling slowly NOTE: Seasonal changes in temperature can cause pressure imbalances within the system resulting in slow water production. Oftentimes the imbalance will correct itself on its own within a few days. You may also restore the internal system pressure balance by draining the tank, unplugging the tubing from the automatic shut off valve (ASV—shown here), then allow the system to stand open overnight.
Home Master® Reverse Osmosis System—Owners Manual 3. If the flow to the membrane housing is weak, then start working your way backward and check each connection point until you find the blockage point. At each point - turn off the water at the EZ adapter and tank, and briefly turn on the RO faucet at the sink to relieve any system pressure. Disconnect the tube from the fitting. Point the tube you have just disconnected into a pitcher and turn on the EZ adapter valve.
Home Master® Reverse Osmosis System—Owners Manual likely not a problem with the RO system directly. Flush & Drain water center, dump at least 2 batches of ice, dispose of foods/leftovers/condiments that are out of code, sanitize shelves and all surfaces. Seal and reseal recent leftovers and frozen goods. Call for support if poor taste persists. No water or ice from refrigerator water center Make sure line from Home Master® RO to refrigerator has pressure.
Home Master® Reverse Osmosis System—Owners Manual USING QUICK CONNECT FITTINGS Page 12 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual Page 13 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual SAMPLE SCHEMATICS Have a problem? Call us 877-693-7873 We want to be part of the solution ______________________________________ Page 14 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual Page 15 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual 10 Tips for an Easy and Successful Installation 1. Keep it simple - there are 4 connections to make, and the tubing is color coded. VIDEO INSTRUCTIONS ARE AVAILABLE ONLINE (6 PARTS) 2. Have plenty of time, light, space, and towels before getting started. If everything goes well, you should be done in 45 minutes. However, if your feed water line is a different size, or if you don’t have an extra hole for the faucet, it can take somewhat longer. 3.