Installation Guide

TestRite® Safety & Usage Instructions**
(800) 321-0316 www.holdrite.com HoldRite® 2019 92-001872-000 (Rev E)
Install TestRite clean out tee, per best
practice; for PVC &ABS with cement
(do not get glue where test device O-
ring must seal) or for No-Hub Cast Iron
with 2 no-hub couplings (when
installing no-hub TestRite tee, be sure
to support the cast iron pipe stack at
each floor level, as required by code).
Remove Spanner Ring and
Clean Out Plug.
Insert Test Wedge into Clean Out Tee, with “pressure
side” up. (Prior to installation, be sure all contact
surfaces are clean and free of excess glue, etc.)
H
and tighten fill/drain stem into Test Wedge clockwise until
snug.
TEST READY
**WARNING: Avoid potential damage or injury close spanner ring securely and DO NOT open while under pressure.
STEP 5
STEP 6a**
STEP 7**
STEP 8a**
To release water down pipe stack, rotate valve stem to the
left (counterclockwise) several full rotations (See Fig C.).
If using Test Wedge with valve stem, turn spigot ball valve to the “closed” position (See Fig A).
Fill pipe stack (maximum 50head/22PSI).
Make sure ball valve is in open position (See Fig B). Fill pipe
stack (maximum 50/22PSI). Then close spigot ball valve.
IF FILLING SYSTEM WITH WATER FROM ABOVE
FILL/DRAIN THROUGH VALVE STEM
METHOD (For Test Wedge with integral
rotary valve only)
RELEASE WATER DOWN
STACK
Fig. A
CLOSED
6” Spanner Ring must be
tightened down to a depth of
at least 1/8” past flush. All
other sizes should be
tightened down at least flush.
OPEN
STEP 8b**
Fig. B
STEP 9**
STEP 10
Confirm that hose is not attached to water source. Rotate
spigot ball valve to open position (See Fig D.) Completely
drain water out.
After water is drained, remove
Spanner Ring. Remove Test
Wedge (with proper care and
handling Test Wedge can be re-
used many times).
Re-install Clean Out Plug and Spanner Ring into Clean
Out Tee. Tighten completely (utilize spanner wrench).
TEST COMPLETE.
RELEASE WATER THROUGH VALVE
STEM WITH HOSE ATTACHED (For
Test Wedge with integral rotary
valve only)
OPEN
Fig. D
STEP 4b
Re-install Spanner Ring
onto Clean Out Tee.
Tighten completely
(utilize spanner wrench).
STEP 1
STEP 2
STEP 3
VERIFY VALVE IS
SEATED TO PROPPER
DEPTH
STEP 4

Summary of content (2 pages)