How to Guide
4 1/2"
26 1/2"
9"
2.25
3.88
7.50
21.50
EXTRUDED THROUGH
FOR 1" COPPER.
.19
NAIL HOLES
.68
1.12
2.50
SLOTS & HOLES=
CLEARANCE FOR
5/8" BOLTS.
ALL DIMENSIONS IN INCHES
.75
23.25
4 1/2"
26 1/2"
9"
800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM
spec_114-C_RevY
PRODUCT SPECIFICATION DRAWING
HOLDRITE® #114-C
Supports flush valves on carriers
The HOLDRITE #114-C is a Copper-Bonded™ steel bracket with two slots for
securely mounting upright to the carrier unit. The top end has a single 1-1/8"
extruded hole for soldering 1" copper pipe, as well as supporting the water pipe
for the flush valve above the floor. Adjust the flush valve 4-1/2" from the carrier
center and 14" above the top fixture mounting bolt. This installation typically
places the flush valve at 11-1/2" above the fixture, When soldering, heat the pipe,
not the bracket.
Product Information:
Material: 16 gage CRS, Copper-Bonded™
•
Provides consistent "rough-in" dimensions
•
Works with all 4 bolts siphon jet carriers
•
Works with current #114-C-EXT brackets
•
UPC / IPC / IAPMO listed
•
THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT
TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN
PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION.