I N S T R U C T I O N S MODEL HVH23 STAND-ALONE EXHAUST HOOD MODELS HVH23 ML-126808 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.
R Ansul Fire Supression System Exhaust Damper Assembly Contactor Box (not shown) mounted to left of Ansul Cabinet Hood Manual Actuator, Fire Supression System Grease Filter Control Printed Circuit Board Drip Cup Fryer (By Customer) Floor Stand NOTE: Optional Back & Side Covers (not shown) Locking Casters PL-53516 MODEL HVH23 STAND-ALONE EXHAUST HOOD –2–
INSTALLATION, OPERATION AND CARE OF MODEL HVH23 STAND-ALONE EXHAUST HOOD PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Hobart Model HVH23 Stand-Alone Exhaust Hood includes a non-vented exhaust fan with three-stage air filtration system and an ANSUL® Fire Suppression System. It enables users of pressure fryers and deep fryers to operate their fryer in a location without an externally-exhausted ventilation hood and wall-mounted fire suppression system.
Locate and identify the following components: 1. 2. 3. 4. 5. 6. 7. * Hood and Fire Suppression System Floor Stand and Contactor Box* ANSULEX® Fire Suppressant, 1.5 gallon Drip Cup Grease Filter Air Filter Refillable Charcoal Filter Back Cover, Right Side Cover, Left Side Cover (optional) LOCATION The installation location must allow adequate clearances for servicing and proper operation. Minimum clearance at the right side and the rear of the unit is 0".
Remove the plastic cover from the Charcoal Filter. The Charcoal Filter goes to the rear of the hood. Notice (Fig. 2) that the actuator pin is pushed in and the filter is resting against the last set of welded pins. Welded Pins Charcoal Filter Actuator Pin Grease Filter Actuator Pin Charcoal Filter Air Filter Actuator Pin Charcoal Filter Actuator Pin PL-40086-1 Fig. 1 PL-40087-1 Fig. 2 The Air Filter is installed next (Fig. 3), and the Grease Filter is installed last at the front of the hood (Fig.
ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT. WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A THREE-PRONG GROUNDING PLUG. THIS PLUG MUST BE CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
OPERATION WARNING: THE EXHAUST HOOD AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE EXHAUST HOOD. CONTROLS On-Off Switch — Located on the left side behind the hood pull. Turns power to the exhaust hood on and off. When turned ON, the reset switch must be pressed to start blowers. Green Interlock Light — When lit, indicates that all hood interlock switches are closed and power is applied to the fryer.
3. Push in the bottom of the Charcoal Filter; tilt the top of the filter forward using the handles; and remove the filter. When the Charcoal Filter needs to be cleaned, it is best to remove the charcoal from the filter. Remove the 4 screws from the filter frame, being careful not to spill the charcoal. Remove the frame end piece. Carefully pour the charcoal from the filter and save it for future reuse, if possible. Replace the frame end piece and 4 screws.