Fault Codes DTC & Troubleshooting

Table Of Contents
2 TROUBLESHOOTING
- 22 -
J.NET, J.NET-INT
LQE540
LQE545
The TX and RX indicators (LEDs) do not come on normally.
Symptom Check if: What to do
The system or NET
information is set correctly.
If not, set it correctly.
The MODU No. and BIT
RATE switches are set
correctly.
If not, set them correctly.
Both TX
and RX are
OFF.
The RI/O STOP terminal on
the LPU’s terminal block is
shorted.
If true, open-circuit the terminal.
A J.NET error is recorded in
the error log.
If true, troubleshoot according to the
instructions given under “4 ERROR
LOG INFORMATION.”
The cable is connected
properly.
If not, connect it properly.
Terminating resistors are
connected properly.
If not, connect them properly.
The slave is in an error
condition.
If true, start up the slave normally.
TX is
flickering,
but RX is
OFF.
The set NET information is in
conflict with the slave.
If true, set NET information again in
conformity with the slave’s
specifications.
A J.NET error is recorded in
the error log.
If true, troubleshoot according to the
instructions given under “4 ERROR
LOG INFORMATION.”
The cable is connected
properly.
If not, connect it properly.
Terminating resistors are
connected properly.
If not, connect them properly.
Both TX
and RX are
flickering.
The set NET information is in
conflict with the slave.
If true, set NET information again in
conformity with the slave’s
specifications.