Fault Codes DTC & Troubleshooting
Table Of Contents
- Cover
- Copyright
- SAFETY PRECAUTIONS
- Revision record
- PREFACE
- CONTENTS
- FIGURES
- TABLES
- 1 PRELIMINARY CHECKING
- 2 TROUBLESHOOTING
- 2.1 Troubleshooting Procedure
- 2.2 Troubleshooting Maps
- LPU
- ● None of the LED indicators comes on.
- ● The ERR indicator (LED) is lit.
- ● The remote I/O process produces outputs but does not accept inputs.
- ● The PCs OK output is OFF.
- ● The sequence program does not run.
- ● A DI/O or AI/O module mounted on the same mount base as is the LPU module does not runnormally.
- CMU
- PS Power supply
- FL.NET
- OD.RING, SD.LINK
- ET.NET (LQE520)
- SV.LINK
- J.NET, J.NET-INT
- IR.LINK
- CPU LINK Inter-CPU link
- RS-232C, RS-422
- D.NET
- EQ.LINK
- ET.NET (LQE720)
- RI/O
- J.Station
- IR.Station
- D.Station
- A.INPUT Analog input
- A.INPUT Scan-type analog input
- A.OUTPUT Analog output
- D.INPUT Digital input
- D.OUTPUT Digital output
- D.IN/OUT Digital input/output
- COUNTER Pulse counter
- Tool (personal computer) connection
- LPU
- 3 TECHNICAL SUPPORT INFORMATION
- 3.1 Remote I/O Troubleshooting
- 3.2 LPU Error Information Detail Table
- 3.3 Clearing the Entire Memory
- 3.4 Backing Up and Restoring
- 3.5 Performance
- 3.6 Address Space Maps
- 3.7 Registers
- 3.8 Memory Maps for Optional Modules
- 3.9 FL.NET (Model LQE500/LQE502) Error Information
- 3.10 OD.RING (Model LQE510/515) and SD.LINK (Model LQE530) Communication Traces
- 3.11 ET.NET (Model LQE520) Error Information
- 3.12 SV.LINK (Model LQE521) Error Information
- 3.13 J.NET (Model LQE541), J.NET-INT (Model LQE547), and IR.LINK (Model LQE548) Trace Information
- 3.14 RS-232C (Model LQE560) and RS-422 (Model LQE565) Trace Information
- 3.15 D.NET (Model LQE570/575) Statistical and Error Information
- 3.16 ET.NET (Model LQE720) Error Information
- 3.17 Error Freeze Information
- 3.18 Memory Dump Procedure
- 3.19 Network Information
- 3.20 Network Maintenance Commands
- 4 ERROR LOG INFORMATION
- 4.1 Displaying Error Log Information
- 4.2 Error Log Information and Required Actions
- 4.2.1 LPU (model LQP510) error log info and required actions
- 4.2.2 CMU (model LQP520) error log info and required actions
- 4.2.3 FL.NET (model LQE500/502) error log info and required actions
- 4.2.4 OD.RING (model LQE510/515) error log info and required actions
- 4.2.5 ET.NET (model LQE520) error log info and required actions
- 4.2.6 SV.LINK (model LQE521) error log info and required actions
- 4.2.7 SD.LINK (model LQE530) error log info and required actions
- 4.2.8 J.NET (model LQE541) / J.NET-INT (model LQE547) error log info and required actions
- 4.2.9 IR.LINK (model LQE548) error log info and required actions
- 4.2.10 CPU LINK (model LQE550) error log info and required actions
- 4.2.11 RS-232C (model LQE560) / RS-422 (model LQE565) error log info and required actions
- 4.2.12 D.NET (model LQE570/575) error log info and required actions
- 4.2.13 EQ.LINK (model LQE701) error log info and required actions
- 4.2.14 ET.NET (model LQE720) error log info and required actions
- 4.2.15 NCP-F (model LQE780-Z) error log info and required actions
- 4.2.16 LANCP (model LQE790-Z/795-Z) error log info and required actions
- 4.3 CMU Error Message Formats
- 4.4 RPDP Error Log Display Guide
- 4.4.1 Reading the error log
- 4.4.2 Types of error logs
- 4.4.3 Error log details and analysis
- (1) Program error
- (2) Macro parameter check error
- (3) I/O error
- (4) Watchdog timer timeout error
- (5) Module error
- (6) Kernel warning
- (7) Kernel information
- (8) System down -- system error
- (9) System down -- kernel trap
- (10) System down -- built-in subroutine error
- (11) System down -- built-in subroutine stoppage
- (12) ADT error
- (13) Memory error
- (14) System bus error
- (15) Other error
- 4.4.4 Reading the DHP trace information
- 4.5 Maintenance Commands
- 5 APPENDIX
- 5.1 Tool Error Messages
- 5.1.1 Error messages from the LADDER CHART SYSTEM
- 5.1.2 Error messages from the HI-FLOW SYSTEM
- 5.1.3 Error messages from the BASE SYSTEM
- 5.1.4 Error messages from the FL.NET SYSTEM
- 5.1.5 Error messages from the OD.RING/SD.LINK SYSTEM
- 5.1.6 Error messages from the ET.NET SYSTEM
- 5.1.7 Error messages from the J.NET SYSTEM
- 5.1.8 Error messages from the IR.LINK SYSTEM
- 5.1.9 Error messages from the CPU LINK SYSTEM
- 5.1.10 Error messages from the EXTERNAL SERIAL LINK SYSTEM
- 5.1.11 Error messages from the D.NET SYSTEM
- 5.1.12 Error messages from the EQ.LINK SYSTEM
- 5.1.13 Error messages from the BACKUP RESTORE SYSTEM
- 5.1.14 Error messages from the NX/Tools-S10V SYSTEM
- 5.1.15 Error messages from the tools
- 5.2 Trouble Report
- 5.1 Tool Error Messages
2 TROUBLESHOOTING
- 22 -
J.NET, J.NET-INT
LQE540
LQE545
The TX and RX indicators (LEDs) do not come on normally.
Symptom Check if: What to do
The system or NET
information is set correctly.
If not, set it correctly.
The MODU No. and BIT
RATE switches are set
correctly.
If not, set them correctly.
Both TX
and RX are
OFF.
The RI/O STOP terminal on
the LPU’s terminal block is
shorted.
If true, open-circuit the terminal.
A J.NET error is recorded in
the error log.
If true, troubleshoot according to the
instructions given under “4 ERROR
LOG INFORMATION.”
The cable is connected
properly.
If not, connect it properly.
Terminating resistors are
connected properly.
If not, connect them properly.
The slave is in an error
condition.
If true, start up the slave normally.
TX is
flickering,
but RX is
OFF.
The set NET information is in
conflict with the slave.
If true, set NET information again in
conformity with the slave’s
specifications.
A J.NET error is recorded in
the error log.
If true, troubleshoot according to the
instructions given under “4 ERROR
LOG INFORMATION.”
The cable is connected
properly.
If not, connect it properly.
Terminating resistors are
connected properly.
If not, connect them properly.
Both TX
and RX are
flickering.
The set NET information is in
conflict with the slave.
If true, set NET information again in
conformity with the slave’s
specifications.