Fault Codes DTC & Troubleshooting
Table Of Contents
- Cover
- Copyright
- SAFETY PRECAUTIONS
- Revision record
- PREFACE
- CONTENTS
- FIGURES
- TABLES
- 1 PRELIMINARY CHECKING
- 2 TROUBLESHOOTING
- 2.1 Troubleshooting Procedure
- 2.2 Troubleshooting Maps
- LPU
- ● None of the LED indicators comes on.
- ● The ERR indicator (LED) is lit.
- ● The remote I/O process produces outputs but does not accept inputs.
- ● The PCs OK output is OFF.
- ● The sequence program does not run.
- ● A DI/O or AI/O module mounted on the same mount base as is the LPU module does not runnormally.
- CMU
- PS Power supply
- FL.NET
- OD.RING, SD.LINK
- ET.NET (LQE520)
- SV.LINK
- J.NET, J.NET-INT
- IR.LINK
- CPU LINK Inter-CPU link
- RS-232C, RS-422
- D.NET
- EQ.LINK
- ET.NET (LQE720)
- RI/O
- J.Station
- IR.Station
- D.Station
- A.INPUT Analog input
- A.INPUT Scan-type analog input
- A.OUTPUT Analog output
- D.INPUT Digital input
- D.OUTPUT Digital output
- D.IN/OUT Digital input/output
- COUNTER Pulse counter
- Tool (personal computer) connection
- LPU
- 3 TECHNICAL SUPPORT INFORMATION
- 3.1 Remote I/O Troubleshooting
- 3.2 LPU Error Information Detail Table
- 3.3 Clearing the Entire Memory
- 3.4 Backing Up and Restoring
- 3.5 Performance
- 3.6 Address Space Maps
- 3.7 Registers
- 3.8 Memory Maps for Optional Modules
- 3.9 FL.NET (Model LQE500/LQE502) Error Information
- 3.10 OD.RING (Model LQE510/515) and SD.LINK (Model LQE530) Communication Traces
- 3.11 ET.NET (Model LQE520) Error Information
- 3.12 SV.LINK (Model LQE521) Error Information
- 3.13 J.NET (Model LQE541), J.NET-INT (Model LQE547), and IR.LINK (Model LQE548) Trace Information
- 3.14 RS-232C (Model LQE560) and RS-422 (Model LQE565) Trace Information
- 3.15 D.NET (Model LQE570/575) Statistical and Error Information
- 3.16 ET.NET (Model LQE720) Error Information
- 3.17 Error Freeze Information
- 3.18 Memory Dump Procedure
- 3.19 Network Information
- 3.20 Network Maintenance Commands
- 4 ERROR LOG INFORMATION
- 4.1 Displaying Error Log Information
- 4.2 Error Log Information and Required Actions
- 4.2.1 LPU (model LQP510) error log info and required actions
- 4.2.2 CMU (model LQP520) error log info and required actions
- 4.2.3 FL.NET (model LQE500/502) error log info and required actions
- 4.2.4 OD.RING (model LQE510/515) error log info and required actions
- 4.2.5 ET.NET (model LQE520) error log info and required actions
- 4.2.6 SV.LINK (model LQE521) error log info and required actions
- 4.2.7 SD.LINK (model LQE530) error log info and required actions
- 4.2.8 J.NET (model LQE541) / J.NET-INT (model LQE547) error log info and required actions
- 4.2.9 IR.LINK (model LQE548) error log info and required actions
- 4.2.10 CPU LINK (model LQE550) error log info and required actions
- 4.2.11 RS-232C (model LQE560) / RS-422 (model LQE565) error log info and required actions
- 4.2.12 D.NET (model LQE570/575) error log info and required actions
- 4.2.13 EQ.LINK (model LQE701) error log info and required actions
- 4.2.14 ET.NET (model LQE720) error log info and required actions
- 4.2.15 NCP-F (model LQE780-Z) error log info and required actions
- 4.2.16 LANCP (model LQE790-Z/795-Z) error log info and required actions
- 4.3 CMU Error Message Formats
- 4.4 RPDP Error Log Display Guide
- 4.4.1 Reading the error log
- 4.4.2 Types of error logs
- 4.4.3 Error log details and analysis
- (1) Program error
- (2) Macro parameter check error
- (3) I/O error
- (4) Watchdog timer timeout error
- (5) Module error
- (6) Kernel warning
- (7) Kernel information
- (8) System down -- system error
- (9) System down -- kernel trap
- (10) System down -- built-in subroutine error
- (11) System down -- built-in subroutine stoppage
- (12) ADT error
- (13) Memory error
- (14) System bus error
- (15) Other error
- 4.4.4 Reading the DHP trace information
- 4.5 Maintenance Commands
- 5 APPENDIX
- 5.1 Tool Error Messages
- 5.1.1 Error messages from the LADDER CHART SYSTEM
- 5.1.2 Error messages from the HI-FLOW SYSTEM
- 5.1.3 Error messages from the BASE SYSTEM
- 5.1.4 Error messages from the FL.NET SYSTEM
- 5.1.5 Error messages from the OD.RING/SD.LINK SYSTEM
- 5.1.6 Error messages from the ET.NET SYSTEM
- 5.1.7 Error messages from the J.NET SYSTEM
- 5.1.8 Error messages from the IR.LINK SYSTEM
- 5.1.9 Error messages from the CPU LINK SYSTEM
- 5.1.10 Error messages from the EXTERNAL SERIAL LINK SYSTEM
- 5.1.11 Error messages from the D.NET SYSTEM
- 5.1.12 Error messages from the EQ.LINK SYSTEM
- 5.1.13 Error messages from the BACKUP RESTORE SYSTEM
- 5.1.14 Error messages from the NX/Tools-S10V SYSTEM
- 5.1.15 Error messages from the tools
- 5.2 Trouble Report
- 5.1 Tool Error Messages
5 APPENDIX
- 365 -
5.1.7 Error messages from the J.NET SYSTEM
Error message Required action
No option module is mounted. Check if the J.NET or J.NET-INT module is installed properly.
The form of J.NET module is unknown. The J.NET or J.NET-INT module may be in a failure condition.
Replace the module.
Enter an address. Although the check box to indicate “addresses not used” is
deselected, no addresses were entered. Enter address values for
the NET1 and NET2 status table addresses.
No station type is selected. Select the desired value as the station type.
Duplicated station ID The specified station number is duplicated with another ID’s.
Set a non-duplicated station number.
The sum of input bytes and output bytes cannot
exceed /100.
Reduce the total number of input and output bytes to /100 or
less.
Neither input byte nor output byte may be 0. When the station type is AUTO, both the input byte and output
byte may not be set to 0. Set either the input or output byte to a
non-zero value.
The address is out of bounds.
Duplicated address
Incorrect address setting was made. Set the correct address
values.
Enter between xxbps to 19200bps The input value was out of the permitted range. Set the
transmission speed to a value in the range xx to 19200, or change
the set value of transmission delay time.
Enter 0 Please enter an integer between xxx and
xxx.
Enter a value of 0 or an integer in the range xx to 32767.
Sending failed The connection was terminated abruptly during data
communication. Check the connection status of the
communication line.
https://www.truck-manuals.net/