4 ERROR LOG INFORMATION
- 222 -
4.2.2 CMU (model LQP520) error log info and required actions
CMU-related errors are reported by presenting error messages in one of the formats shown under
“4.3 CMU Error Message Formats.”
(1/4)
No. Error code Error message Brief description Error classification Error location Abend type Required action
1 EC=03620000 Program error (Invalid Data Access) Data access error Software TASK TASK ABORT Program correction
2 EC=03660000 Program error (Data Access Protection) Data access protection error Software TASK TASK ABORT Program correction
3 EC=03600000 Program error (Data Page Fault) Data access page fault Software TASK TASK ABORT Program correction
4 EC=03420000 Program error (Invalid Inst. Access) Instruction access error Software TASK TASK ABORT Program correction
5 EC=03460000 Program error (Inst. Access Protection) Instruction access protection error Software TASK TASK ABORT Program correction
6 EC=03400000 Program error (Instruction Page Fault) Instruction access page fault Software TASK TASK ABORT Program correction
7 EC=03030000 Program error (Inst. Alignment Error) Instruction alignment error Software TASK TASK ABORT Program correction
8 EC=03080000 Program error (Privileged Instruction) Privileged-instruction violation Software TASK TASK ABORT Program correction
9 EC=03040000 Program error (Illegal Instruction) Illegal instruction error Software TASK TASK ABORT Program correction
10 EC=03390000 Program error (FP Program Error) Floating-point arithmetic error Software TASK TASK ABORT Program correction
11 EC=03470000 Program error (Data Alignment Error) Data alignment error Software TASK TASK ABORT Program correction
12 EC=05130000 Macro parameter error Undefined macro issued Software TASK TASK ABORT Program correction
13 EC=05110000 Macro parameter error Macro parameter abnormal Software TASK TASK ABORT Program correction
14 EC=07xxxxxx I/O error (error detail message) Network I/O error Hardware I/O For details, see
4.2.15 and 4.2.16.
15 EC=05C70000 WDT timeout error Watchdog timer timeout Hardware TASK Program correction
16 EC=03B70000 Module error (Bus Target Abort) Bus target abort Hardware I/O Hardware
replacement or
program correction
(*)
17 EC=05000000 Module error (Invalid Interrupt) Invalid interrupt Hardware CMU Hardware
replacement
18 EC=05000001 Module error (Undefined Invalid
Interrupt)
Undefined invalid interrupt Hardware CMU Hardware
replacement
19 EC=05000002 Module error (INTEVT Invalid
Interrupt)
INTEVT invalid interrupt Hardware CMU Hardware
replacement
20 EC=0500F001 Module error (HERST Invalid Interrupt) Serious-error invalid interrupt Hardware CMU Hardware
replacement
21 EC=0500F002 Module error (HERST2 Invalid
Interrupt)
Serious-error invalid interrupt 2 Hardware CMU Hardware
replacement
22 EC=0500F003 Module error (BUERRSTAT Invalid
Interrupt)
Bus serious-error interrupt status
invalid
Hardware CMU Hardware
replacement
23 EC=0500F006 Module error (NHPMCLG Invalid
Interrupt)
Memory serious-error interrupt
status invalid
Hardware CMU Hardware
replacement
24 EC=0500F007 Module error (ECC 2bit Master Invalid
Interrupt)
Memory ECC-detected 2-bit
serious error status invalid
Hardware CMU Hardware
replacement
25 EC=0500F008 Module error (RERRMST Invalid
Interrupt)
RERR interrupt status invalid Hardware CMU Hardware
replacement
26 EC=0500C001 Module error (NINTR Invalid Interrupt) NINT status invalid Hardware CMU Hardware
replacement
27 EC=0500B001 Module error (PUINTR Invalid
Interrupt)
PUINT status invalid Hardware CMU Hardware
replacement
28 EC=05005001 Module error (RINTR Invalid Interrupt) RINT status invalid Hardware CMU Hardware
replacement
29 EC=05003001 Module error (LV3 INTST Invalid
Interrupt)
Level-3 interrupt status invalid Hardware CMU Hardware
replacement
30 EC=05003002 Module error (RQI6 INF Invalid
Interrupt)
RQI6 status invalid Hardware CMU Hardware
replacement
31 EC=05001001 Module error (RQI3 INT Invalid
Interrupt)
RQI3 status invalid Hardware CMU Hardware
replacement
32 EC=05001002 Module error (RQI3 Link Invalid
Interrupt)
RQI3 link status invalid Hardware CMU Hardware
replacement
33 EC=05001003 Module error (RQI3 Module Invalid
Interrupt)
RQI3 module status invalid Hardware CMU Hardware
replacement
34 EC=0D010000 Module error (Memory Alarm) Memory 1-bit error (solid) Hardware CMU Hardware
replacement
(*) This type of error may also occur when the target module is under initialization or in a stop state. In these cases, hardware replacement is unnecessary.