Datasheet
Z5K500 OEM Specifications
24
6.1.2 Corrosion test
The hard disk drive must be functional and show no signs of corrosion after being exposed to a
temperature humidity stress of 50°C/90%RH (relative humidity) for one week followed by a temperature
and humidity drop to 25'C/40%RH in 2 hours.
6.1.3 Radiation noise
The hard disk drive shall work without degradation of the soft error rate under the following magnetic flux
density limits at the enclosure surface.
Frequency (KHz) Limits (uT RMS)
DC 1500 0-p
0 < Frequency =< 60 500 RMS
60 < Frequency =<100 250 RMS
100 < Frequency =< 200 100 RMS
200 < Frequency =< 400 50 RMS
Table 13 Magnetic flux density limits
6.1.4 Conductive noise
The hard disk drive shall work without soft error degradation in the frequency range from DC to 20 Mhz
injected through any two of the mounting screw holes of the hard disk drive when an AC current of up to
45 mA (p-p) is applied through a 50-ohm resistor connected to any two mounting screw holes.
6.1.5 Atmospheric condition
"Environments that contain elevated levels of corrosives (e.g. hydrogen sulfide, sulfur oxides, or
hydrochloric acid) should be avoided. Care must be taken to avoid using any compound/material in a
way that creates an elevated level of corrosive materials in the atmosphere surrounding the disk drive.
Care must also be taken to avoid use of any organometallic (e.g. organosilicon or organotin)
compound/material in a way that creates elevated vapor levels of these compounds/materials in the
atmosphere surrounding the disk drive."