ICC ESR-2269 for X-U Universal and X-P Concrete Powder Driven Fasteners

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 13
ICC-ES Evaluation Report
ESR-2269
Reissued February 2021
This report is subject to renewal February 2023.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council
®
DIVISION: 03 00 00—CONCRETE
Section: 03 15 00—Concrete Accessories
Section: 03 16 00—Concrete Anchors
DIVISION: 04 00 00—MASONRY
Section: 04 05 19.16—Masonry Anchors
DIVISION: 05
00 00—METALS
Section: 05 05 23—Metal Fastenings
DIVISION: 06
00 00—WOOD, PLASTICS AND
COMPOSITES
Section: 06 05 23—Wood, Plastic, and Composite
Fastenings
REPORT HOLDER:
HILTI, INC.
EVALUATION SUBJECT:
HILTI LOW-VELOCITY X-U AND X-U 15 UNIVERSAL
FASTENERS AND X-P CONCRETE FASTENERS
1.0 EVALUATION SCOPE
Compliance with the following codes:
2018, 2015, and 2012 International Building Code
®
(IBC)
2018, 2015, and 2012 International Residential Code
®
(IRC)
For evaluation for compliance with codes adopted by the
Los Angeles Department of Building and Safety (LADBS),
see ESR-2269 LABC and LARC Supplement.
Property evaluated:
Structural
2.0 USES
2.1 General:
The Hilti X-U and X-P power-actuated fasteners (PAFs) are
used to attach wood, light gage steel, and other building
elements to base materials of normalweight concrete, sand-
lightweight concrete, steel deck panels with sand-
lightweight concrete fill and concrete masonry. The X-U
fasteners are also used to attach building elements to steel
base materials. The Hilti X-U 15 fasteners are used to attach
light gage steel and other building elements to steel base
material. The fasteners are alternatives to the cast-in-place
anchors described in IBC Section 1901.3 (2012 IBC Section
1908; 2009 IBC Section 1911) for placement in concrete;
the embedded anchors described in Section 8.1.3 of TMS
402, referenced in Section 2107 of the IBC (Section 2.1.4 of
TMS 402-11 and -08 referenced in Section 2107 of the 2012
and 2009 IBC, respectively), for placement in masonry; and
the welds and bolts used to attach materials to steel,
described in IBC Sections 2204.1 and 2204.2, respectively.
For structures regulated under the IRC, the fasteners may
be used where an engineered design is submitted in
accordance with IRC Section R301.1.3.
2.2 Horizontal Diaphragms:
The Hilti X-U fasteners may be used as alternates to 10d
common nails for fastening wood structural panels to
structural steel members in horizontal diaphragms.
3.0 DESCRIPTION
3.1 Fasteners:
3.1.1 X-U: The X-U fasteners are powder-driven fasteners
made from hardened steel complying with the
manufacturer’s quality documentation, austempered to a
Rockwell C nominal hardness of 57.5 and zinc-plated in
accordance with ASTM B633 SC 1, Type III. The fasteners
have a shank diameter of 0.157 inch (4.0 mm), a head
diameter of 0.32 inch (8.2 mm) and a knurled tip, and come
in lengths ranging from 0.63 inch to 2.83 inches
(16 to 72 mm). See Figure 1 for the fastener configuration.
3.1.2 X-U 15: The X-U 15 fasteners are powder-driven
fasteners made from hardened steel complying with the
manufacturer’s quality documentation, austempered to a
Rockwell C nominal hardness of 59 and zinc plated in
accordance with ASTM B633 SC 1, Type III. The fasteners
have a shank diameter of 0.145 inch (3.7 mm), a head
diameter of 0.32 inch (8.2 mm) and a shank length of
0.63 inch (16 mm). See Figure 2 for the fastener
configuration.
3.1.3 X-P: The X-P fasteners are powder-driven fasteners
made from hardened steel complying with the
manufacturer’s quality documentation, austempered to a
Rockwell C nominal hardness of 59 and zinc plated in
accordance with ASTM B633 SC 1, Type III. The fasteners
have a shank diameter of 0.157 inch (4.0 mm), a head
diameter of 0.32 inch (8.2 mm) and come in lengths ranging
from 0.87 inch to 1.57 inches (22 to 40 mm). See Figure 3
for the fastener configuration.
3.2 Substrate Materials:
3.2.1 Concrete: Normal-weight and sand-lightweight
concrete must comply with IBC Chapter 19 or IRC Section
R402.2, as applicable. The minimum concrete compressive
strength at the time of fastener installation must be as noted
in the applicable allowable load table. Hollow core precast
concrete slabs must conform to the cross-sectional
dimensions shown in Figure 7.

Summary of content (13 pages)