Operating Instruction DD 110-W (01)
Table Of Contents
- Original operating instructions
- 1 Information about the documentation
- 2 Safety
- 3 Description
- 4 Technical data
- 5 Use of extension cords
- 6 Preparations at the workplace
- 7 Types of work
- 8 Care and maintenance
- 9 Transport and storage
- 10 Troubleshooting
- 11 Disposal
- 12 Manufacturer’s warranty
- 13 Further information
- Mode d'emploi original
- 1 Indications relatives à la documentation
- 2 Sécurité
- 3 Description
- 4 Caractéristiques techniques
- 5 Utilisation de rallonges électriques
- 6 Préparatifs
- 6.1 Réglage de la poignée latérale
- 6.2 Montage de la couronne diamantée avec le porte-outil BI+
- 6.3 Démontage de la couronne diamantée avec le porte-outil BI+
- 6.4 Montage des couronnes pour percement avec dispositif d'aspiration des poussières
- 6.5 Sélection de la vitesse de rotation
- 6.6 Installation du raccordement d'eau
- 7 Travail
- 7.1 Protection contre le vol TPS (en option)
- 7.2 Utilisation d'une amorce de forage constituée de deux éléments
- 7.3 Activation du disjoncteur à tension nulle PRCD
- 7.4 Forage à sec avec dispositif d'aspiration de poussière
- 7.5 Forage à sec sans dispositif d'aspiration de poussières
- 7.6 Forage à eau
- 7.7 Desserrage de la couronne de forage à l'aide d'une clé à fourche
- 7.8 Arrêt
- 8 Nettoyage et entretien
- 9 Transport et entreposage
- 10 Aide au dépannage
- 11 Recyclage
- 12 Garantie constructeur
- 13 Informations complémentaires
- Manual de instrucciones original
- 1 Información sobre la documentación
- 2 Seguridad
- 3 Descripción
- 4 Datos técnicos
- 5 Uso de alargadores
- 6 Preparación del trabajo
- 6.1 Ajuste de la empuñadura lateral
- 6.2 Montaje de la corona perforadora de diamante con portaútiles BI+
- 6.3 Desmontaje de la corona perforadora de diamante con portaútiles BI+
- 6.4 Montaje de los avellanadores cilíndricos con sistema de aspiración de polvo
- 6.5 Selección de la velocidad
- 6.6 Instalación de la toma de agua
- 7 Procedimiento de trabajo
- 7.1 Protección antirrobo TPS (opcional)
- 7.2 Uso de la guía de centrado de dos piezas
- 7.3 Manejo del interruptor de corriente de defecto PRCD
- 7.4 Taladrado en seco con aspiración
- 7.5 Taladrado en seco sin aspiración
- 7.6 Taladrado en mojado
- 7.7 Extracción de la corona perforadora mediante llave de boca
- 7.8 Desconexión
- 8 Cuidado y mantenimiento
- 9 Transporte y almacenamiento
- 10 Ayuda en caso de averías
- 11 Reciclaje
- 12 Garantía del fabricante
- 13 Más información
- Manual de instruções original
- 1 Indicações sobre a documentação
- 2 Segurança
- 3 Descrição
- 4 Características técnicas
- 5 Utilização de extensões de cabo
- 6 Preparação do local de trabalho
- 7 Trabalhar
- 7.1 Sistema de proteção antirroubo TPS (opcional)
- 7.2 Utilização da broca de centragem de duas peças
- 7.3 Operar o disjuntor de segurança PRCD
- 7.4 Perfuração a seco com extração de pó
- 7.5 Perfuração a seco sem sistema de remoção de pó
- 7.6 Perfuração a húmido
- 7.7 Soltar a coroa de perfuração com a chave de forqueta
- 7.8 Desligar
- 8 Conservação e manutenção
- 9 Transporte e armazenamento
- 10 Ajuda em caso de avarias
- 11 Reciclagem
- 12 Garantia do fabricante
- 13 Mais informações
*351007*
351007 English 11
2. Optional: Install and use the two-part hole-starting aid. → page 10
3. Plug the diamond core drilling machine's supply cord into the power outlet of the vacuum extractor.
4. Plug the vacuum extractor’s supply cord into the power outlet.
5.
When connected: Press the Reset switch or I button of the PRCD.
6. Center the diamond core drilling machine where the hole is to be drilled.
7. Press the on/off switch on the diamond core drilling machine.
The vacuum extractor will start after the power tool has started. When you switch off the power
tool the vacuum extractor will run on for a short time before switching itself off.
7.4.2 Dry-drilling with using a vacuum extractor without power outlet for power tools
Use slotted core bits only when working without a dust removal system.
1. Secure the side handle in the desired position.
2. Optional: Install and use the two-part hole-starting aid. → page 10
3. Plug the vacuum cleaner’s supply cord into the power outlet and switch the vacuum cleaner on.
4. Plug the supply cord of the diamond core drilling machine into the power outlet and then press the
"Reset button or I button of the PRCD.
5. Center the diamond core drilling machine where the hole is to be drilled.
6. Press the on/off switch on the diamond core drilling machine.
7. To ensure removal of residual material, let the vacuum cleaner run on for a few seconds after you switch
off the diamond core drilling machine.
7.5 Dry drilling without dust removal
If dry drilling without a dust removal system is carried out, use slotted core bits. Wear suitable
breathing protection!
Do not drill upward when working without a dust removal system.
Remove the dust removal attachment or secure it to prevent rotation.
1. Secure the side handle in the desired position.
2. Optional: Install and use the two-part hole-starting aid. → page 10
3.
Plug the supply cord into the power outlet and press the Reset button or I button of the PRCD.
4. Center the diamond core drilling machine where the hole is to be drilled.
5. Press the on/off switch on the diamond core drilling machine.
7.6 Wet drilling
WARNING
Danger of electric shock! There is a possibility of water flowing over the motor and cover if the vacuum
removal system is faulty.
▶ Cease operations immediately if the vacuum removal system is not working.
For drilling upward, the use of a wet vacuum cleaner in conjunction with a water collection system is
a mandatory requirement!
1. Secure the side handle in the desired position.
2. Optional: Install and use the two-part hole-starting aid. → page 10
3. Center the diamond core drilling machine where the hole is to be drilled.
4. Slowly open the water flow regulator until the desired volume of water is flowing.
5. Press the on/off switch on the diamond core drilling machine.
6. When you start drilling apply only light pressure until the core bit has centered itself. Then apply more
pressure.