Operating Instruction VC 300-17 X (01)
English 5
3.4 Control switch
Symbol Meaning
Switching on
Switching off
Switching on, with filter cleaning
3.5 Automatic filter cleaning
The appliance is equipped with a filter cleaning system for fine dust. The filter is cleaned automatically every
7.5 seconds by a blast of air.
4 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the appliance’s
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer’s power output must be at
least twice the rated input power shown on the rating plate of the appliance. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the appliance.
VC 300-17 X
Weight
63.1 lb
(28.6 kg)
Mains connection (type)
SJTWA 3/14 AWG
Maximum volumetric flow rate (air)
2 x 157 CFM (2 x 74 ℓ/s)
Container capacity
17 liq. gal
US
(65 ℓ)
Water capacity
13 liq. gal
US
(48 ℓ)
Suction hose connector (C-DN/C-ID)
1.6 in
(40 mm)
Vacuum (max.)
3.7 psi
(254 mbar)
Ambient temperature (max.)
104 ℉
(40 ℃)
Automatic filter cleaning, all
7.5 s
Protection class
I
Protection class
IPX4
5 Before use
CAUTION
Risk of injury presented by the appliance running away out of control. The vacuum cleaner may
run away out of control if the wheel brakes are not engaged.
▶ Engage the wheel brakes so that the vacuum cleaner stands securely.
Printed: 22.02.2017 | Doc-Nr: PUB / 5334131 / 000 / 00