Pourstop Substitution Request for X-U

Table 1 - Allowable Weld Design Values Pounds Per Inch of Fillet Weld or
Per Hilti X-U Powder-Actuated Fastener
Pullover Shear
20 360 445
18 490 525
16 685 720
14 825 1085
12 935 1085
10 - -
20 360 445
18 490 525
16 685 720
14 825 1085
12 935 1085
10 - -
1.) Based upon AISI Manual for Cold-Formed Steel Design, 2008 Edition Table IV-1 assuming the transverse condition, which is the highest capacity.
Table 2 - Allowable Load Capacities for Hilti Powder-Actuated Fasteners from ICC-ES ESR-2269
1
Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear
X-U - - 535 720 775 720 935 720 900 720 350 375
1.) Reference Table 2 of ESR-2269 for complete details regarding the load values provided in this table.
Weld Length #1 1
Weld Length #2 2
Weld Length #3 3
Weld Length #4 4
1/2"
Fillet Weld
1
689
X-U
Tension or Shear
Fastener Designation
996
1328
373665
65
1/4" 3/16"1/8" 3/4"3/8"
Base Steel Thickness
Pourstop Thickness
(GA)
Pourstop Steel
Fu (ksi)
65
1438
2013
2587
919
1660
45
65
1149
45
45
65 2906
65 2077
45
45
45