Product Technical Guide for DBV Facade

DBV Rainscreen Facade Product Technical Guide
62
www.hilti.com
MFT-FOX HT
Base Material: Steel studs
Distance Between Steel Studs: 16" = 406.4mm
Thickness of steel studs: 16 gauge = 1.29mm
Wind load evaluation considering:
Exposure: C Risk Cat.: II
Height: 100 ft (30.48 m) Zone: W4
Wind speed: ≤95 mph (42.47 m/s) Example according to ASCE 7-16 Wind Map:
Wind load: 27 lb/ft² (±1.28 kN/) Seattle, Portland, Sacramento, LA, SF, SD, Las Vegas, Dallas
1-Rail Vertical - 0-2.9 lb/ft² (0-14 kg/m²) Panel
Brackets
(1.5" - 5.5" / 40-140mm)
L-rails T-rails Screws Base Fastener
Medium 2-1/2"x2"x0.1" 2-1/2"x4"x0.1" S-AD 01S 5.5x19 S-MD 51S 5.5x50
Metric
[pieces/m²] [m/m²] [m/m²] [pieces/m²] [pieces/m²]
1.93 1.21 0.61 3.85 3.85
Imperial
[pieces/ft²] [ft/ft²] [ft/ft²] [pieces/ft²] [pieces/ft²]
0.18 3.98 1.99 0.36 0.36
Wind speed: ≤110 mph (49.17 m/s) Example according to ASCE 7-16 Wind Map:
Wind load: 36 lb/ft² (±1.28 kN/m²) Boston, NY, NJ, Philladelphia, DC, Chicago
1-Rail Vertical - 0-5.1 lb/ft² (0-25 kg/m²) Panel
Brackets
(1.5" - 5.5" / 40-140mm)
L-rails T-rails Screws Base Fastener
Medium 2-1/2"x2"x0.1" 2-1/2"x4"x0.1" S-AD 01S 5.5x19 S-MD 51S 5.5x50
Metric
[pieces/m²] [m/m²] [m/m²] [pieces/m²] [pieces/m²]
2.82 1.78 0.89 5.65 5.65
Imperial
[pieces/ft²] [ft/ft²] [ft/ft²] [pieces/ft²] [pieces/ft²]
0.26 5.83 2.92 0.52 0.52
SYSTEM LOAD TABLES
These tables represent common situation within our offering. Buckling considered in all cases and seismic load not considered.