X-FCM NG Data Sheet

www.hilti.group
13 09 / 2021
X-FCM NG
Design resistance under tension load for grating fastening system
Designation Grating type Clear bar
spacing
w
bearing bar
Base material
steel grade
Base material
thickness
t
II
Tension
load
N
Rd
X-FCM-R NG
combined with
S-BT-GR NG
M8/7 SN 6
Rectangular
grating
13 mm
S235 to
S275,
S280GD to
S350GD
3 ≤ t
II
≤ 5 mm 2.5 kN18 mm
22 mm
13 mm
t
II
≥ 5 mm 2.7 kN18 mm
22 mm
13 mm
S355, S420,
S390GD to
S420GD
3 ≤ t
II
≤ 5 mm 3.0 kN18 mm
22 mm
13 mm
t
II
≥ 5 mm
3.2 kN
18 mm 3.2 kN
22 mm 2.9 kN
X-FCM-M NG
combined with
S-BT-GR NG
M8/7 SN 6
Rectangular
grating
13 mm
S235 to
S275,
S280GD to
S350GD
3 ≤ t
II
≤ 5 mm
2.5 kN
18 mm 2.5 kN
22 mm 1.7 kN
13 mm
t
II
≥ 5 mm
2.7 kN
18 mm 2.7 kN
22 mm 1.7 kN
13 mm
S355, S420,
S390GD to
S420GD
3 ≤ t
II
≤ 5 mm
3.0 kN
18 mm 3.0 kN
22 mm 1.7 kN
13 mm
t
II
≥ 5 mm
3.2 kN
18 mm 2.9 kN
22 mm 1.7 kN
X-FCM-M NG
combined with
S-BT-GF NG
M8/7 AN 6
Rectangular
grating
13 mm
S235 to
S275,
S280GD to
S350GD
3 ≤ t
II
≤ 5 mm
2.7 kN
18 mm 2.7 kN
22 mm 1.7 kN
13 mm
t
II
≥ 5 mm
2.8 kN
18 mm 2.8 kN
22 mm 1.7 kN
13 mm
S355, S420,
S390GD to
S420GD
3 ≤ t
II
≤ 5 mm
3.2 kN
18 mm 2.9 kN
22 mm 1.7 kN
13 mm
t
II
≥ 5 mm
3.3 kN
18 mm 2.9 kN
22 mm 1.7 kN