Operating Instruction DG 150

10 English
Quick stop after power OFF
2 s
Optimum gap between lamellar seal and work surface
0 mm …1 mm
(0 in …0.04 in)
4.2 Technical data, DPC 20
Note
If the device is powered by a generator or transformer, the generator or transformer’s power output
must be at least twice the rated input power shown on the rating plate of the device. The operating
voltage of the transformer or generator must always be within +5 % and -15 % of the rated voltage of
the device.
The information given applies for a rated voltage of 230 V. Actual figures can vary for country-specific
versions and if the voltage supply differs. For rated voltage, frequency, input power and rated current,
refer to the country-specific type identification plate.
110 V
Rated current
16 A
Power input
1,760 W
Rated frequency
50/60 Hz
Weight of the DPC 20 in accordance with EPTA procedure 01/2003
3.8 kg
(8.4 lb)
5 Operation
5.1 Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1 Adjusting the guard
1. Set the device on the work surface.
2. Release the clamping lever.
3. Turn the retaining ring with lamellar seal until the gap between lamellar seal and work surface is correct.
4. Turn the guard to the desired position.
5. Close the clamping lever.
Note
If the guard is not secure when the lever is in the closed position, tighten the clamping band by
turning the adjusting screw clockwise with a screwdriver.
If the guard is too tight to move when the lever is in the open position, slacken the clamping band
by turning the adjusting screw counter-clockwise with a screwdriver.
5.1.2 Adjusting the guard for working close to an edge
1. Release the clamping lever.
2. Turn the top part of the guard relative to the bottom part until the desired position is reached.
3. Set the device on the work surface.
4. Turn the retaining ring with lamellar seal until the gap between lamellar seal and work surface is correct.
5. Close the clamping lever.
Note
More dust can escape past the guard when the device is used for working close to an edge.
Printed: 20.11.2017 | Doc-Nr: PUB / 5385705 / 000 / 01