Operating Instruction VC 300-17 X (01)

12 English
7.4 Checking the container level monitoring system
1. Engage the wheel brakes so that the vacuum cleaner stands securely.
2. Disconnect the supply cord plug from the power outlet.
3. Open the two catches.
4. Lift the vacuum cleaner top section away from the waste material container and place it on a level surface.
5. Check the cut-out contacts and clean them with a brush if necessary (if dirty).
6. Check the seal at the vacuum cleaner top section and clean it with a cloth if necessary.
7. Fit the vacuum cleaner top section onto the waste material container and close the two catches.
7.5 Checks after cleaning and maintenance
1. After cleaning or carrying out maintenance, check that the vacuum cleaner is assembled correctly and
that it functions faultlessly.
2. Test each of the functions.
7.6 Transport
Do not carry the appliance when it is full of waste material.
The appliance may not be lifted directly by crane.
Remove the power conditioner (if applicable) or loose accessory tools from the holder.
Empty the appliance before carrying it to another location.
Do not tip the appliance or transport it lying on its side after using it to pick up liquids.
Use the tapered adapter to connect both ends of the hose together conveniently for transport.
7.7 Storage
Store the vacuum cleaner in a secure, dry place where it is inaccessible to unauthorized users.
8 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
8.1 Troubleshooting
Trouble or fault Possible cause Action to be taken
The vacuum turbine doesn’t
start.
No electric power. Check the power outlet and
fuse.
The probes are clogged with dirt. Check the container level
monitoring system.
The vacuum turbine switches
itself off.
The container is full. Empty the container.