Operating Instruction AG 500-11S (05)

Table Of Contents
English 19
6.2.1 Installing the guard
The guard is keyed to ensure that only guards of a type suitable for use
with the product can be installed. The keyed locating lug also prevents
the guard from coming into contact with the tool.
1. Fit the guard on to the arbor collar so that the two triangular marks on the
guard and on the product are in alignment.
2. Press the guard on to the drive spindle collar.
3. Press the guard release button and turn the guard until it engages in the
desired position.
The guard release button jumps back.
6.2.2 Adjusting the guard
Press the guard release button and then rotate the guard until it engages
in the desired position.
6.2.3 Removing the guard
1. Press the guard release button and turn the guard until the triangular
marks on the guard and on the product are in alignment.
2. Lift off the guard.
Printed: 19.10.2018 | Doc-Nr: PUB / 5402264 / 000 / 01