SIW 6 ATA22 en fr es pt Original operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Mode d'emploi original . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Manual de instruções original . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Manual de instrucciones original . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Printed: 05.12.
Printed: 05.12.
1 Information about the documentation 1.1 About this documentation • • • Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and use of the product. Observe the safety instructions and warnings in this documentation and on the product. Always keep the operating instructions with the product and make sure that the operating instructions are with the product when it is given to other persons. 1.2 Explanation of symbols used 1.2.
1.4 Declaration of conformity We declare, on our sole responsibility, that the product described here complies with the applicable directives and standards. A copy of the declaration issued by the certification department can be found at the end of this documentation. The technical documentation is filed and stored here: Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistrasse 6 | 86916 Kaufering, Germany 2 Safety 2.
▶ ▶ ▶ ▶ ▶ ▶ Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired. Disconnect the battery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
Electrical safety ▶ Before starting work, check the working area for concealed electric cables or gas and water pipes. If you damage an electric cable accidentally, external metal parts of the power tool may become live and present a risk of electric shock. Careful handling and use of power tools ▶ Switch the power tool off immediately if the accessory tool jams. The power tool may go off course and veer to the side. ▶ Wait until the power tool has come to a complete stop before setting it down. 2.
Rated speed under no load Setting III Impact speed Torque adjustment Large standard bolts Large high-strength bolts Chuck 0 Hz … 45.0 Hz (0 /min … 2,700 /min) ≤ 3,500 bpm Three settings (additional settings are possible when using the intelligent torque module SIAT22 and the torque display shows "AT") M8 to M16 M6 to M12 /2″ square drive with ball-notch retention 1 5 Operation 5.1 Preparations at the workplace CAUTION Risk of injury! Inadvertent starting of the product.
5.1.4 Removing the accessory tool CAUTION Risk of injury. The accessory tool may be hot or have sharp edges. ▶ Wear protective gloves when using the power tool and when changing accessory tools. 1. Set the forward/reverse switch to the middle position or remove the battery from the power tool. 2. Pull the accessory tool off the square drive. 5.1.5 Setting the torque ▶ Select one of the following alternatives: 5.1.5.
Conditions + Operation without the intelligent torque module 1. Move the forward/reverse switch into the middle position. 2. Use the torque selector button to set the desired torque. → page 6 3. Set the forward/reverse switch to the desired direction of rotation. Note When using the intelligent torque module, the torque selector button does not work.
Storage CAUTION Inadvertent damage caused by defective battery. A leaking battery may damage the tool. ▶ ▶ ▶ ▶ ▶ Always remove the battery before storing the tool. Store the tool and batteries in a place that is as cool and dry as possible. Never store batteries in direct sunlight, on heating units or behind a window pane. Store the tool and batteries in a place where they cannot be accessed by children or unauthorized persons.
9 Disposal WARNING Risk of injury. Hazards presented by improper disposal. ▶ ▶ ▶ Improper disposal of the equipment may have the following consequences: The burning of plastic components generates toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit unauthorized and improper use of the equipment.