3.4 MI Components, Allowable Load Data and Specications
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I MI/MQ Technical Guide 2015
56
MI steel connectors: MIC-S120-A/B
MIC-S120-A
1
5
1
/
2
"
(140)
MIC-S120-B
2
5
1
/
2
"
(140)
Allowable loads for MIC-S120-A on steel ange
± Fx (lb) ± Fy (lb) ± Fz (lb) ± Mx (ft-lb) ± My (ft-lb) ± Mz (ft-lb)
+4900/-5160 1100 1100 325 900 675
Allowable loads for MIC-S120-A + MIB on steel web
± Fx (lb) ± Fy (lb) ± Fz (lb) ± Mx (ft-lb) ± My (ft-lb) ± Mz (ft-lb)
+4900/-6770 1325 1325 390 590 675
1 Fastened with four MI-SGC-M12 beam clamps (item 233859), order separately.
Allowable loads for MIC-S120-B on steel ange
± Fx (lb) ± Fy (lb) ± Fz (lb) ± Mx (ft-lb) ± My (ft-lb) ± Mz (ft-lb)
+3530/-5160 1100 1100 430 900 675
Allowable loads for MIC-S120-B + MIB on steel web
± Fx (lb) ± Fy (lb) ± Fz (lb) ± Mx (ft-lb) ± My (ft-lb) ± Mz (ft-lb)
+3530/-3200 1325 1325 510 900 675