Trouble or fault Possible cause Action to be taken
The exhaust gas piston return
unit jams.
Build-up of combustion residues. Service the tool.
The tool cannot be fired The tool was not pressed fully
against the working surface.
Press the tool fully against the
working surface.
The piston is incorrectly
positioned.
Remove the cartridge strip and
clean the tool.
Check the piston and buffer and
replace if necessary.
7.2 Problems with fasteners to be driven into steel
Malfunction Possible cause Action to be taken
The fastener doesn’t pene-
trate deep enough
Driving power is too low. Increase driving power (adjust
power regulating wheel).
Use a more powerful cartridge.
The application limits have been
exceeded (very hard material).
Use a more powerful system,
e.g. DX 76 (PTR).
The fastener doesn’t hold in
the base material.
Thin supporting steel (45 mm) Use a different power setting or
different cartridge power level.
Fastener breakage.
Driving power is too low. Increase driving power (adjust
power regulating wheel).
Use a more powerful cartridge.
The application limits have been
exceeded (very hard material).
Use a more powerful system,
e.g. DX 76 (PTR).
Driving power is too high. Reduce driving power (adjust
the power regulating wheel).
Use a less powerful cartridge.
Use the nails with a "top hat".
Use the nails with a washer.
The fastener is driven too
deep.
Driving power is too high. Reduce driving power (adjust
the power regulation wheel).
Use a less powerful cartridge.
7.3 Problems with the cartridges
Malfunction Possible cause Action to be taken
The cartridge strip doesn’t
advance.
The cartridge strip is damaged. Change the cartridge strip.
The tool has too much built-up dirt
and residues.
Service the tool.
If necessary, have the tool
checked by Hilti Service.
The tool is damaged. If the problem persists, contact
Hilti Service.
Printed: 02.08.2018 | Doc-Nr: PUB / 5292636 / 000 / 02