6. Power on the device again.
The barrier will open automatically and turns back to the closed position. At this circumstance,
the device enters the normal mode.
Note: For details about the DIP switch value and meaning, see Appendix B DIP Switch
Description.
5.2 Pairing Keyfob (Optional)
Purpose:
Pair the keyfob to the device through DIP switch to open/close the barrier remotely.
Note: for details about the keyfob’s operations, see the related user manual.
Before you start:
Ask our technique supports or sales and buy the keyfob.
Steps:
1. Power off the swing barrier.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board according to the figure
below.
3. Power on the swing barrier and it will enter the keyfob pairing mode.
4. Hold the Close button for more than 10 seconds.
The keyfob’s indicator will flash twice if the pairing is completed.
Notes:
You can also pair the keyfob via the client software. For details, see Managing keyfob in
7.2.6 Remote Configuration.
Only one swing barrier can pair the keyfob. If multiple swing barriers are in the keyfob
pairing mode, the keyfob will select only one of them to pair.
For details about DIP switch value and meaning, see Appendix B DIP Switch Description.
5.3 Initializing Device
Steps:
1. Remove the JP11 jumper cap.
2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep.
3. When the beep stopped, plug the jumper cap back.
4. Disconnect the power and reboot the device.
Note: The initializing of the device will restore all the parameters to the default setting and all
the device events are deleted.