Manual

Network Video Recorder User Manual
UM NVR v4.xx 111717NA 161
The camera connection will be disabled when the device works in hot spare mode.
It is highly recommended
to restore the the device defaults after switching the working
mode of the hot spare device to normal mode to ensure normal operation afterwards.
17.2 Set Working Device
Step 1 Go to System > Hot Spare.
Step 2 Set the Work Mode to Normal Mode.
Step 3 Check Enable.
Step 4 Enter the IP address and admin password of the hot spare device.
Figure 17-3 Hot Spare
Step 5 Click Apply.
17.3 Manage Hot Spare System
Step 1 Go to System > Hot Spare in the hot spare device.
Step 2 Check working devices on the device list and click Add to link the working device to the
hot spare device.
A hot spare device can connect up to 32 working devices.