Data Sheet

FIVENORM
HAR-UL-CSA-AWM-MTW,PVCsinglecore,ULStyle10269/ULStandard1063,
600V,105°C
PropertiesCablestructureTechnicaldata
Barecopperfinewirestrandedto
DINVDE0295cl.5,BS6360cl.5and
IEC60228cl.5,acc.toULStd.758
PVC-singlecoresacc.to
DINVDE0285-525-2-31/
DINEN50525-2-31,ULStd.1063,
ULStyle10269andCSA-TEWand
CSA-AWMIA/B
Thematerialsusedduringmanufacturing
arecadmium-free,containnosilicone
andarefreefromsubstancesharmful
tothewettingpropertiesoflacquers CoreinsulationofPVC
compoundtypeTI3to
DINVDE0207-363-3/DINEN50363-3
CSA-C22.2No.210tab.12classH
andclass43acc.toULStd.1581
Tests
Temperaturerange
H05V2-K/H07V2-K
flexing+5°Cto+90°C
fixedinstallation-40°Cto+90°C
UL(AWM)-40°Cto+105°C
UL(MTW)-40°Cto+90°C
CSA(TEW)-40°Cto+105°C
PCVself-extinguishingandflameretardant
acc.toDINVDE0482-332-1-2,
DINEN60332-1-2,IEC60332-1-2
(equivalentDINVDE0472part804
testmethodB),ULVW-1,CSAFT1
CoreidentificationtoDINVDE0293
Note
Nominalvoltage
upto1mm²H05V2-K:U
0
/U300/500V
from1,5mm²H07V2-K:U
0
/U450/750V
UL(AWM)1000V(AC)
UL(AWM)1250V(DC)
UL(MTW)600V
CSA(TEW)600V
Tinnedconductoronrequest.
upto=1,0mm²=H05V2-K,
from1,5mm²upto35mm²=H07V2-K.
Cross-sectionsupto35mm²isacc.to
DINVDE0285-525-2-31.Duetothis
crosssection>35mm²isthetypeH07V-K
butwithanincreasedheat-resistant
PVC-compoundTI3.
Testvoltage
H05V2-K=2000V
H07V2-K=2500V
TypeH05V:
approvedone-colourmark:black,blue,
brown,grey,orange,pink,red,turquoise,
violet,white,greenandyellow.
Two-colouredmarkinanycombinationof
theaboveindividualcolours.
Testvoltage(SparkTest)
0,5mm²=5kV
≥0,75mm²=6kV
Insulationresistance
min.20MOhmxkm
TypeH07V:
approvedmark:black,blue,brown,grey,
orange,pink,red,turquoise,violet,white
andgreen-yellow.
Othermarksareavailableas(H).
Minimumbendingradius
fixedinstallationforcoreØ:
≤8mm:4xcoreØ
>8-12mm:5xcoreØ
>12mm:6xcoreØ
Application
Fivenormsapprovedconnectingjumperwireprimarilydesignedforexportes,usedinmachinetools.TheapprobationofHAR,UL-AWM,UL-MTW,
CSA-AWM,CSA-Equipment-wiremakepossibleaneconomicalstorekeepingandsimplificationofpartslist.
=ProductconformswithLow-VoltageDirective2014/35/EU.
Cop.
weight
kg/km
OuterØ
app.mm
Cross-sec.
mm²
/AWG-no.
2-col.o.col.OGD-BUTRANSGNPKYEVTGYWHRDBNBUGN-YEBK
--20035010-601830151021400570001013300080035015-9005
app.RAL
64090640896408864087640866408564084640836408264081640806407964078640776407664075Partno.
5,22,50,5 /22
64106641056410464103641026410164100640996409864097640966409564094640936409264091Partno.
7,22,650,75 /20
64122641216412064119641186411764116641156411464113641126411164110641096410864107Partno.
9,62,81 /18
Continuation
27.09.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.