INSTRUCTION FOR INSTALLATION AND USE - GARANTY You have just acquired this radiant radiator DIAMANT/EMERAUDE And we thank you for your choice. This device has been studied, designed and realized with care, In order to give you full satisfaction.
Summary I. Markings & Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 II. General Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Precautions for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 III. Installation of radiator DIAMANT/EMERAUDE . . . . . . . . . . . . . . . . . . . . . . . . 6 Composition . . .
I. Markings and indications DIAMANT/DIAMANT/EMERAUDE 400 x 1200 cm / 16’ x 48’ reference : THERMAL POWER Nominal Thermal Power P nom 500 W Minimal Thermal Power ( indicative) P min 450 W Maximal Thermal Power (constant) P max 525 W At nominal thermal power C el 500 W/h At minimal thermal power C el min 450 W/h In Sleep mode C el veil 0.
II. General Instructions Before installing and using your DIAMANT/EMERAUDE radiator, please read these instructions carefully and observe the following instructions : SAFETY INSTRUCTIONS -The electrical connection must be carried out by a qualified electrician. The installation must be protected by a 25 or 30 mA differential circuit- breaker (NFC15-100 electrical safety standard). The power supply outage must be of omnipolar type (phase and neutral cut-off).
For a bathroom installation, observe the zone of use in compliance with the protection index IP44: zones 2 and more Bath Volume Shower with receiver Volume Shower without receiver Volume IPPROTECTION ACCESSORIES No Plug Plug supplied by safety transformer Plug protected by 30mA RCD MATERIAL Low voltage (12 to 30V) Class II and RCD 30mA or Low voltage Plug protected by 30mA RCD The heater should not be placed directly below a power outlet.
This device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or persons without experience or knowledge, unless they have been By a person responsible for their safety, supervision or prior instructions relating to the use of the appliance and that the risks incurred have been apprehended. The radiator DIAMANT/ EMERAUDE is a certified device for its performance and safety.
III. Installation of radiator DIAMANT/ EMERAUDE COMPOSITION The DIAMANT/EMERAUDE extra-fine design radiator consists of: • From a tempered glass decorative surface, • From an aluminum heating film (patented), • A mounting system for an installation Horizontal or vertical wall, • IN OPTION; An electrical box and a radio receiver for proper operation of the thermostat (See package insert).
INSTALLATION AND FITTING To facilitate installation of your DIAMANT/EMERAUDE radiator, a template is provided. It is represented on the back of the packaging (actual dimensions). • Reminder of drilling centers Horizontal SPACING In mm DIAMANT/EMERAUDE 400x1200 DIAMANT/EMERAUDE 400x1800 HORIZONTAL SPACING x 966 / 38,03’ VERTICAL SPACING Y 290/ 11.42’ 1566 /61.65’ 290 /11.42’ VERTICAL SPACING In mm DIAMANT/EMERAUDE 400x1200 DIAMANT/EMERAUDE 400x1800 HORIZONTAL SPACING x 290 /11.
• Attaching the radiator to the wall Fix the 2 wall brackets with 4 dowels and 4 screws adapted to the material of your wall. Glue the 4 foam pads underneath each Hole as shown in the illustration opposite. Position the radiator on the wall brackets By sliding it correctly into the holes. Lock the radiator the lateral safety screw provided. (Left or right of choice).
• Electrical connection Connect electrically. L = Phase (brown) N = Neutral (blue) The electrical connexion must be made with a IPX4 box , class II, in compliance with regulation. PILOT WIRE = FP (black) Do not plug in if you are not connected to an automated system that manages the Pilot wire. Please go page 24 for more detailled information. Protect the supply line with a circuit breaker differential of 25 or 30 mA. Clean with a soft, damp cloth before heating.
IV. Technical characteristics of radiator DIAMANT/EMERAUDE Voltage: ~120V/AC (60Hz) Maximal Intensity per radiator: 5A Protection Class: II Potection Index: IP44 Indicated power per room: 54W/m² Conformity: UL499 & UL2021 DIAMANT/DIAMANT/EMERAUDE RANGE TO DISCOVER www.ilo-international.com Power - Area to heat 500W - 10m² 750w - 15m² 750W - 15m² 1100W - 20m² WIDTH 400mm 400mm 600mm 600mm LENGTH 1200mm 1800mm 1200mm 1800mm ATTENTION: Electric Chocs danger.
V. Help with diagnosis NATURE OF THE PROBLEM THE RADIATOR DOESN’T HEAT THE RADIATOR HEAT PERMANANTLY CONTROL 1. Ensure that the green light is lighting (power) and the red light is lighting too 2. The status light Function is on (green), the Heater is switched off, the Red light is not lit on the side of your radiator 3.
VI. Guarantee • 5 years for the heating element of the radiator DIAMANT/EMERAUDE and 2 years for the Programmable electronic thermostat. • The warranty period starts from the date of purchase on the Invoice or receipt. • This warranty applies in addition to all standard laws. GUARANTEE CONDITIONS Any request for guarantee is subject to compliance with the following terms and conditions: • This warranty is valid only for domestic use in dry space.
GUARANTEE CERTIFICATE In case of damage during the warranty period or later, please Contact the manufacturer below: • email : derrick@heatstorm.com • HOT LINE : +1 435.752.6611 In the case of a return service, please attach this document filled with the invoice. N ame: Email : Street : Product : ZIP code: Date of purchase : City : Installater : Country : Date of installation : Tel. : Please attach a copy of the purchase invoice. HEATSTORM / ENERGYWISE SOLUTIONS 700 W. 1700 S.