Figure 17 - Equipment Shuto Valve
Open
Closed
Equipment
Shuto󰀨 Valve
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shuto󰀨 valve (see Fig-
ure 17).
2. Pressurize supply piping system by either
opening propane supply tank valve for
propane gas or opening main gas valve
located on or near gas meter for natural
gas or using compressed air.
3. Check all joints from gas meter to
equipment shuto󰀨 valve for natural gas
or propane supply to equipment shuto󰀨
valve for propane (see Figure 18 or 19).
Apply a noncorrosive leak detection uid
to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on
page 18). Check all other internal joints
for leaks.
7. Turn o󰀨 heater (see To Turn O Gas Ap-
pliance, page 19).
8. Replace front panel.
1. Open equipment shuto󰀨 valve (see Fig-
ure 17).
2. Open main gas valve located on or near
gas meter for natural gas or open propane
gas supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shuto󰀨
valve to control valve (see Figure 18 or
19). Apply a noncorrosive leak detection
uid to all joints. Bubbles forming show a
leak.
Gas Valve
Equipment
Shuto󰀨 Valve
Propane
Supply Tank
Figure 18 - Checking Gas Joints for
Propane Gas
Figure 19 - Checking Gas Joints for
Natural Gas
INSTALLATION
Gas Valve
Equipment Shuto󰀨 Valve
Gas
Meter
External
Regulator
Supplied by
Gas Supplier