Figure 3-11 Gang Box
Note
•
The dimension of g
ang box is: 343 (W) × 113 (H) × 55 (D) mm.
•
The dimensions above are for reference only. The actual size can be slightly
dierent from the
theorecal dimension.
3.3.2 Flush Mounng with Gang Box
Steps
1.
Drill a hole in the w
all for inserng the gang box. The size of the hole should be
lar
ger than that of the gang box. The suggested size of the hole is 343.5 (W) ×
113.5 (H) × 55.5 (D) mm.