Figure 2-4 Exit
Buon Wiring
Note
Terminal BTN1/BTN2 can both connect to exit buon.
2.2.4 External Card Reader Wiring
Note
•
Please se
t the DIP switch rst before connecng the card reader.
•
If the DIP s
witch should be congured when the card reader is power-on, please
r
eboot the card reader aer conguring the DIP switch.
•
The DIP switch descripon is shown in the following table:
Table 2-2 DIP Switch Descripon
No. Descripon How to Congure
1 to 4 Set the RS-485 address ON: 1
OFF: 0
6 Select Wiegand protocol or
R
S-485 protocol
ON: Wiegand
Video Intercom D Series Door Staon User Manual