User's Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Model
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Local Settings
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.4.1 Add Organization
- 7.4.2 Configure Basic Information
- 7.4.3 Issue a Card to One Person
- 7.4.4 Collect Fingerprint via Client
- 7.4.5 Collect Fingerprint via Access Control Device
- 7.4.6 Configure Access Control Information
- 7.4.7 Customize Person Information
- 7.4.8 Configure Resident Information
- 7.4.9 Configure Additional Information
- 7.4.10 Import and Export Person Identify Information
- 7.4.11 Import Person Information
- 7.4.12 Export Person Information
- 7.4.13 Get Person Information from Access Control Device
- 7.4.14 Move Persons to Another Organization
- 7.4.15 Issue Cards to Persons in Batch
- 7.4.16 Report Card Loss
- 7.4.17 Set Card Issuing Parameters
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.7.1 Configure Device Parameters
- 7.7.2 Configure Remaining Open/Closed
- 7.7.3 Configure Multi-Factor Authentication
- 7.7.4 Configure Custom Wiegand Rule
- 7.7.5 Configure Card Reader Authentication Mode and Schedule
- 7.7.6 Configure First Person In
- 7.7.7 Configure Anti-Passback
- 7.7.8 Configure Device Parameters
- 7.8 Configure Linkage Actions for Access Control
- 7.9 Door Control
- 7.10 Event Center
- 7.11 Time and Attendance
- 7.12 Remote Configuration (Web)
- 7.12.1 View Device Information
- 7.12.2 Change Device Password
- 7.12.3 Time Management
- 7.12.4 System Maintenance
- 7.12.5 Configure RS-485 Parameters
- 7.12.6 Security Mode Settings
- 7.12.7 Network Parameters Settings
- 7.12.8 Report Strategy Settings
- 7.12.9 Network Center Parameters Settings
- 7.12.10 Configure Wi-Fi
- 7.12.11 Set Relay Parameters
- 7.12.12 Set Access Control Parameters
- 7.12.13 Set CPU Card Reading Mode
- 7.12.14 Configure Volume Input or Output
- 7.12.15 Operate Relay
- 7.13 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. Dimension
- Appendix C. Communication Matrix and Device Command
7. Click Add to import the devices.
8. Perform the following operaons aer adding the devices.
Remote
Conguraon
Click on Operaon column to set remote conguraon of the
c
orresponding device.
Note
• For some models of devices, you can open its web window. To open
the original r
emote conguraon window, press Ctrl and click
.
•
For detail operaon steps for the remote conguraon, see the user
manual of the de
vice.
Device Status Click on Operaon column to view device status.
7.2.2 Reset Device Password
If you forgot the password of the detected online devices, you can reset the device password
thr
ough the client.
Steps
1. Enter Device Management page.
2. Click Online Device to show the online device area.
All the online devices in the same subnet will display in the list.
3. Select the device from the list and click
on the Operaon column.
4. Click Export t
o save the device le on your PC and then send the le to our technical support.
Note
For the following operaons for
reseng the password, contact our technical support.
Cauon
The password strength of the device can be automacally checked. We highly recommend you
chang
e the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case leers, lower case leers, numbers, and special
characters) in order to increase the security of your product. And we recommend you change
your password regularly, especially in the high security system, changing the password monthly
or weekly can beer protect your product.
Proper conguraon of all passwords and other security sengs is the responsibility of the
installer and/or end-user.