6771 STOP! Call Us First! DO NOT RETURN TO STORE. For immediate help with assembly or product information call our toll-free number: 1--800-221-1849 or email: customerservice@backyardproductsllc.com Our staff is ready to provide assistance.
(This page intentionally left blank.
ASSEMBLY MANUAL 16771 3/15/2013 A Backyard Products Company MONTANA 8' x 9' 8-5/8" (244 x 296 cm) ACTUAL FLOOR SIZE IS 96 x 116-5/8" (244 x 296 cm) KEEP THIS MANUAL FOR FUTURE REFERENCE IMPORTANT! READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY.
TOOLS Required ❑ Phillips Screwdriver ❑ Drill / Driver ❑ #2 Philips Drive Bit ❑ Drill / Driver ❑ 1/4" (0,6 cm) Drill Bit ❑ 3/8" (1 cm) Drill Bit ❑ 1/2" (1,3 cm) Drill Bit Optional ❑ Utility Knife ❑ Shingle Blades ❑ Tool Belt/ Nail Pouch ❑ Caulk Gun ❑ Tin Snips (for drip edge) ❑ Saws-All/ Sabre Saw ❑ Chalk Line ❑ Nail Gun ❑ Gun nails ❑ Paint Tools ❑ Hammer ❑ Level ❑ Safety Glasses ❑ Pencil ❑ Ladder ❑ Tape Measure ❑ Gloves ❑ Square or Safety! Always use approved safety glasses during assembly.
ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • This shed kit provides directions for a wood floor system, which is not included. • This shed does not include any leveling materials. • See the FLOOR LEVELING section on page 9 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site. REINFORCED WOOD FLOOR FRAME (OPTIONAL) IMPORTANT! The included floor has been designed for general use.
PARTS IDENTIFICATION AND SIZES WOOD SIZE CONVERSION CHART Part identification is stamped on some parts. Nominal Board Size Actual Size 2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) RS 1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm) RS 2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) 1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm) • Check these locations for part stamp. PARTS LIST TRIM LOFT RAFTERS WALLS FLOOR INVENTORY YOUR PARTS before you begin.
WALL PANEL & DOORS PARTS LIST x1 x1 PANEL PARTS LIST NOTE: Panel parts are not stamped with part identification. Loft panel is 7/16" (1,1 cm) thick.
WALL PANEL & DOORS PARTS LIST x1 x1 x1 x1 LEFT BACK LEFT FRONT RIGHT FRONT RIGHT BACK NOTE: Panels have a primed side.
MATERIAL NOT INCLUDED (FOR 24" O.C. FLOOR) NAIL BOXES FLOOR PANELS Floor panels are 5/8" (1,6 cm) thick Oriented Strand Board (OSB).
BUILDING ANATOMY 8 6 4 4 7 3 2 5 1 9 This building has been designed using our patented EZ Frame construction method. EZ Frame is a unique construction method which has been engineered to use fewer framing members. This reduces assembly time and cost by as much as 30% compared to conventional construction methods. EZ Frame patent no. 5,666,766 All of our buildings have been engineered to withstand demanding wind and snow loads.
FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS 4x4 Runners (not included) • 3" Screw angled into 4x4. • (2) at each point frame and 4x4 touch. 12" (30,5 cm) 12" (30,5 cm) MATERIAL REQUIRED 96" (244 cm) Measurements to centers of 4x4's. x2 4" x 4" x 10' (10 x 10 x 305 cm)Treated Lumber Fasteners for Frame to 4"x 4".
CONCRETE FOUNDATION Your kit contains all materials to construct a wooden floor. If you choose to install your kit on a concrete slab refer to the diagram below. Treated Sill Plate Caulk between sill plate and concrete. 3-1/2" (8,9 cm) B C A DOOR Building Size 4" (10 cm) Actual Floor Size A 8' x 10' (244 x 305 cm) 8' x 9'-8-5/8" (244 x 296 cm) 96" (244 cm) B C 109-5/8" (278 cm) 116-5/8" (296 cm) Requires: x2 2 x 4 x 10' (5 x 10 x 305 cm) MUST be treated lumber.
FLOOR FRAME PARTS REQUIRED: x2 x6 x2 x28 3" (7,6 cm) TREATED 2 x 4 x 24" (5 x 10 x 61 cm) NOTE: Look for TREATED 2 x 4 x 93" (5 x 10 x 236 cm) Stamp. TREATED 2 x 4 x 92-5/8" (5 x 10 x 235,3 cm) BEGIN 1 Orient parts as shown on flat surface. Measure and mark from end of boards. 2 Use two 3" nails at each mark. 3 DO OR FINISH You have finished your floor frame. Proceed to level and square frame.
FLOOR FRAME LEVEL AND SQUARE FLOOR FRAME Before attaching floor decking, it is important to level and square the floor frame. A level and square floor frame is required to correctly construct your shed. BEGIN 1 See page 8 for the preferred floor leveling method. Use level and check the frame is level before applying floor panels. 3 Check for frame squareness by measuring diagonally across corners. If the measurements are the same, the frame is square.
FLOOR PANELS (Not included) PARTS REQUIRED: x1 x55 2" (5 cm) Floor panels not included. See page 3 for panel sizes and quantities. 5/8 x 48 x 96" (1,6 x 122 x 244 cm) Ensure your floor frame is square by installing one panel and squaring frame. BEGIN Attach the 48 x 96" panel with the rough side up (painted-grid lines side) with the 48" edge and corner flush to the floor frame (Fig A). Secure panel with two 2" nails in the corners. 2 Move to the opposite end.
FLOOR PANELS (Not included) PARTS REQUIRED: x1 x95 2" (5 cm) x1 5/8 x 48" x 96" (1,6 x 122 x 244 cm) 5/8 x 20-5/8 x 96" (1,6 x 52,4 x 244 cm) 5 Continue installing panels with rough side up (painted grid lines). 6 Use a chalk line or grid lines on panels for 2" nails 6" apart on edges and 12" apart inside panel. . 7 DO OR FINISH You have finished installing your floor panels.
IMPORTANT! IMP O R TA N T ! Check the floor frame is level after installing floor panels. Re-level if needed. OR DO • The floor should be used as a stable work surface for wall construction. HINT: • Organize your assembly procedure during the build process to avoid over-handling of the walls.
BACK WALL FRAME x2 PARTS REQUIRED: x1 3" (7,6 cm) NK 2 x 3 x 48" (5 x 7,6 x 144 cm) x1 PT 2 x 3 x 96" (5 x 7,6 x 243,8 cm) BEGIN 1 Orient parts on edge on floor as shown. Measure and mark. Nail using two 3" nails at connection. DO OR 2 HINT: For easier nailing stand on frame.
BACK WALL FRAME x2 PARTS REQUIRED: x1 3" (7,6 cm) LT 2 x 3 x 22-1/8" (5 x 7,6 x 56,2 cm) 3 Orient parts on edge on floor as shown. 4 Use two 3" screws at middle connection. FINISH You have finished building your back wall frame.
BACK WALL PANELS PARTS REQUIRED: 1-1/4" (3,2 cm) RIGHT LEFT x1 x24 x2 x1 x1 OB 2 x 3 x 72-5/8" (5 x 7,6 x 184,5 cm) OO 2 x 3 x 69" (5 x 7,6 x 175,3 cm) TEMPORARY SUPPORT BEGIN Place OB on floor. Place the left back wall panel primed side down onto OB (Fig. A) and flush to panel edges as shown. 2 Secure flush to edges using twelve 1-1/4" (3 cm) screws 6" apart. 3 Repeat Steps 1-2 to assemble the right back wall panel.
INSTALL BACK WALL JOIST PARTS REQUIRED: x1 x6 OO 1-1/4" (3,2 cm) 2 x 3 x 69" (5 x 7,6 x 175,3 cm) TEMPORARY SUPPORT x1 VW 1 x 4 x 96" (2,5 x 10 x 243,8 cm) BEGIN 1 Place VW on floor. Place the left back wall panel primed side up onto VW as shown. Measure and mark for correct placement. Secure using six 1-1/4" (3 cm) screws as shown.
BACK WALL PANELS PARTS REQUIRED: DU 2 x 3 x 36" (5 x 7,6 x 91,4 cm) x1 3 GAA LEFT Pre-assembled Place LEFT panel on BACK WALL FRAME as shown with primed side facing up. Use a 3/4" gauge block at edges of panel. 4 3/4" (19 mm) Position DU as shown. Maintain 1/2" (12 mm) gap as shown (For loft deck installed later.) 5 3/4" GAUGE BLOCK x1 Pre-assembled 2" (5 cm) Secure using 2" nails 6" apart on edges and 12" apart inside panel.
BACK WALL PANELS PARTS REQUIRED: x6 x21 1-1/4" (3,2 cm) 2" (5 cm) RIGHT LEFT x1 x1 Pre-assembled Pre-assembled 6 Place RIGHT panel on back frame as shown with primed side facing up. 7 Secure using 2" nails 6" apart on edges and 12" apart inside panel. 8 Secure VW using six 1-1/4" (3 cm) screws as shown. 9 DO OR FINISH You have finished the lower back wall.
GABLE PANELS AND TRIM PARTS REQUIRED: x4 NX x2 x24 2 x 3 x 35-7/16" (5 x 7,6 x 90 cm) x2 LEFT 1-1/4" (3 cm) RIGHT BEGIN 1 You will be attaching trim NX from the backside of the gable panels (Fig. A). You will assemble TWO RIGHT and TWO LEFT assemblies. 2 Place trim NX on floor. 3 Place a left or right gable panel onto trim primed side down (Fig.A). 4 Locate trim NX flush to edges and secure with six 1-1/4" screws 6" apart. 5 Repeat steps 1-4 to assemble two left and two right assemblies.
BACK WALL GABLE PANELS INSTALL PARTS REQUIRED: x6 GAA x1 Pre-assembled LEFT LEFT 2" (5 cm) 3/4" GAUGE BLOCK RIGHT RIGHT x1 Pre-assembled BEGIN Position lower back wall and LEFT BACK GABLE primed side UP on floor. Place flush to top and use a 3/4" gauge block at edge of panel as shown. (Fig. A) Fig. A Primed side UP Secure with 2" nails 6" apart. Flush DO OR 1 3/4" GAUGE BLOCK LEFT Use 2 x 3 for temporary support Fig.
BACK WALL GABLE TRIM PARTS REQUIRED: x2 3 x12 NY 1-1/4" (3 cm) 2 x 3 x 34-1/8" (5 x 7,6 x 86,7 cm) Place NY between existing trim under backwall primed side down and secure with 1-1/4" screws 6" apart. Repeat on other side. FINISH You have finished building your backwall. DO OR 4 Two points contact each other Primed side is down. 1-1/4" (3 cm) Screws NY NY 6" (15 cm) Apart Carefully slide the back wall off the floor.
FRONT WALL FRAME PARTS REQUIRED: x1 x2 x1 LG 2 x 3 x 12-1/4" (5 x 7,6 x 31 cm) x18 LN 3" (7,6 cm) 2 x 3 x 16-1/2" (5 x 7,6 x 42 cm) NZ 2 x 3 x 22-7/8" (5 x 7,6 x 58,1 cm) x3 OZ 2 x 3 x 70-1/4" (5 x 7,6 x 178 cm) x1 PS 2 x 3 x 91" (5 x 7,6 x 231 cm) BEGIN 1 Orient parts on edge on floor as shown. Measure and mark. 2 Nail using two 3" nails at each connection.
FRONT WALL PANELS PARTS REQUIRED: x1 x24 x1 x2 1-1/4" (3,2 cm) OB 2 x 3 x 72-5/8" (5 x 7,6 x 184,5 cm) BEGIN Place OB on floor. Place the right front wall panel primed side down onto OB (Fig. A) and flush to panel edges as shown. 2 Secure flush to edges using twelve 1-1/4" (3 cm) screws 6" apart. 3 Repeat Steps 1-2 to assemble the left front wall panel. DO OR 1 FINISH You have finished building your front wall panels.
FRONT WALL PANELS PARTS REQUIRED: x1 x6 x25 2" (5 cm) 2" (5 cm) 96" (244 cm) Z-STRIP - Cut into two 29" (73,7 cm) lengths BEGIN Place right panel on front frame as shown with primed side facing up. 2 Measure and cut Z-Strip into two 29" lengths. 3 Position Z-strip as shown. Secure Z-strip using six 2" finish nails 6" apart. 4 Secure the rest of panel using (16) 2" nails 6" apart.
FRONT WALL PANELS PARTS REQUIRED: x25 2" (5 cm) x6 2" (5 cm) x1 Place left panel on front frame flush to right panel as shown with primed side facing up. 6 Repeat Steps 3-4. FINISH 7 Angle nails to draw panels tight at seams You have finished the lower front wall.
FRONT WALL GABLE PANELS PARTS REQUIRED: x16 GAA 2" (5 cm) 3/4" GAUGE BLOCK x1 LEFT RIGHT Pre-assembled x1 DO O R Pre-assembled BEGIN 1 Place the left gable panel primed side up onto wall frame and Z-strip and onto LN. Nail with 2" nails 6" apart. 2 3/4" GAUGE BLOCK Flush LEFT 6" (15 cm) Apart Place right gable panel primed side up onto wall frame and Z-strip and onto LN and flush to left gable panel. RIGHT Flush 6" (15 cm) Apart Nail with 2" nails 6" apart.
FRONT WALL GABLE TRIM PARTS REQUIRED: x2 4 x14 1-1/4" (3,2 cm) NY 2 x 3 x 34-1/8" (5 x 7,6 x 86,7 cm) Place NY onto front wall between existing trim, and secure from inside with 1-1/4" screws 6" apart. FINISH You have finished building your front wall.
SIDE WALL FRAMES PARTS REQUIRED: x4 x40 NH 3" (7,6 cm) 2 x 3 x 46-1/4" (5 x 7,6 x 117,5 cm) x8 OU 2 x 3 x 68-3/4" (5 x 7,6 x 174,6 cm) x4 OZ 2 x 3 x 70-1/4" (5 x 7,6 x 178 cm) BEGIN 1 Orient parts as shown on flat surface. Measure and mark each dimension from end of boards. 2 Use two 3" nails at each mark, and toenail at seam. 3 Repeat Steps 1-2 to assemble the second wall frame. 46-1/4" (117,5 cm) 22-1/4" (57 cm) DO OR IMPORTANT! You will build two walls the same.
SIDE WALL PANELS PARTS REQUIRED: x40 GAA 3/8 x 48 x 72" (1 x 122 x 183 cm) x2 2" (5 cm) 3/4" GAUGE BLOCK Ensure your wall frame is square by installing one panel and squaring frame. 4 Place the 48 x 72" panel onto wall frame with primed side up as shown. Measure and mark overhangs and top spacing. Ensure measurements result in correct dimensions for 1" bottom spacing. DO OR Use the gauge block to mark the 3/4" measurement on the wall stud. Secure panel with two 2" nails in the top corners (Fig.
10' x 8' SIDE WALL PANELS PARTS REQUIRED: 3/8 x 23-7/8 x 72" (1 x 61 x 183 cm) 3/8 x 48 x 72" (1 x 122 x 183 cm) For squareness maintain 3/4" side measurement and 5/8" measurement at top plate. 7 2" (5 cm) x2 5/8" (16 mm) DO OR x2 x80 Place 48" panel on frame as shown with primed side facing up. Secure panels with two 2" nails at the upper corners. 3/4" (19 mm) Secure using 2" nails 6" apart on edges and 12" apart inside panels.
BACK WALL INSTALLATION PARTS REQUIRED: x4 x17 x1 3" (7,6 cm) 2" (5 cm) OO 2 x 3 x 69" (5 x 7,6 x 175,3 cm) TEMPORARY SUPPORT BEGIN 1 Center back wall assembly on the 96" (244 cm) floor dimension. 2 Use OO as a temporary brace. Secure with two 3" screws. DO OR 3" (7,6 cm) Screws 3 First, nail lower edge of panel to floor frame using 2" nails 6" apart. Angle nail to hit floor frame (Fig. A). 4 Screw back wall uprights to floor using two 3" screws (Fig. B).
SIDE WALLS INSTALLATION PARTS REQUIRED: x20 x70 x4 3" (7,6 cm) 3" (7,6 cm) 2" (5 cm) BEGIN Stand right side wall on floor. It is important to secure the side wall in the following order. Center side wall on floor front to back. DO OR 1 Trim Nail the lower side wall corner to the back wall trim with one 2" nail (Fig. A). 2" (5 cm) Nail DOOR Fig. A CENTER 2 Be sure the measurement between the panel edge and the trim is the same along the entire length.
FRONT WALL INSTALLATION PARTS REQUIRED: x10 x32 3" (7,6 cm) 2" (5 cm) BEGIN Stand front wall on floor. It is important to secure the front wall in the following order. 1 Center front wall on floor side-to-side. DO OR Nail the front wall flush to the floor using 2" nails 6" apart. Angle nails to hit floor frame (Fig. A). Nail the lower side wall corner to the front wall trim with one 2" nail (Fig. B). Fig. A Trim 2" (5 cm) Nail 2 6" (15 cm) 6" (15 cm) CENTER Fig.
RAFTERS PARTS REQUIRED: x96 Pre-assembled x8 RAFTER-HALF x1 OO 2" (5 cm) x8 GUSSET 2 x 3 x 69" (5 x 7,6 x 175,3 cm) TEMPORARY SUPPORT BEGIN You will build FOUR assemblies; Place two rafter-halves in the corner of back and side walls. The RED ENDS identify the ends to be connected at the center. 96" (244 cm) HINT: Use floor and walls to help assemble rafters! DO OR 1 Fit base of rafters in corners of back wall.
GABLE TRIM INSTALL PARTS REQUIRED: x1 x10 3/4" (1,9 cm) HQA 1 x 3 x 70-1/2" (2,5 x 7,6 x 179,1 cm) BEGIN 1 On outside of back wall, center HQA on seam between existing trim. Secure with ten 3/4" (1,9 cm) screws 6" (15 cm) apart) from inside as shown. 3 DO OR FINISH You have finished installing your gable trim.
RAFTERS PARTS REQUIRED: x16 3" (7,6 cm) Rafter Assemblies x4 BEGIN 1 Measure and mark center of wall studs onto side of top plate. Center four rafters on marks. (Fig. A). The rafters also line up directly over the wall studs. Check you have the measurements shown. DO OR Toenail with two 3" screws at each end (Fig. A). FINISH 2 You have finished installing your rafters.
LOFT JOISTS PARTS REQUIRED: x2 x8 3" (7,6 cm) VW 1 x 4 x 95" (2,5 x 10 x 241,3 cm) BEGIN 1 Place a loft joist flush on the back side of each of the back two rafters. 2 Attach each joist with one 3" screw toenailed through the joist into the top plate. Screw through each loft joist into the rafters with another 3" screw as shown. 3 DO OR Check rafters are still 24" on center. FINISH 4 You have finished installing your loft joists.
LOFT PANEL PARTS REQUIRED: x1 x4 2" (5 cm) 7/16 x 48 x 84-3/8" (1,1 x 122 x 214,3 cm) BEGIN 1 IMPORTANT! Using only four 2" nails, nail loft panel in place to allow racking of the roof. You will complete nailing the loft panel later. DO OR 2 Place loft panel grid side up onto the three loft joists centered from side-to-side and flush with the back wall panel. Panel will fit into the gap left earlier and on the jloist of the back wall.
ROOF PANELS PARTS REQUIRED: x4 2" (5 cm) GAA x1 7/16 x 35-3/8 x 96" (1,1 x 89,9 x 244 cm) 3/4" GAUGE BLOCK Roof panels may cause serious injury until securely fastened. DO OR You must square the roof by attaching one panel fist. You will use the panels’ long edge as a lever to bring your roof into square. Commonly known as “racking”.
ROOF PANELS PARTS REQUIRED: x1 x2 3 x170 x2 7/16 x 35-3/8 x 96" (1,1 x 89,9 x 244 cm) x2 7/16 x 23-7/8 x 96" (1,1 x 61 x 244 cm) 7/16 x 23-7/8 x 35-3/8" (1,1 x 61 x 89,9 cm) x2 x2 7/16 x 11-1/2 x 96" (1,1 x 29,2 x 244 cm) 7/16 x 11-1/2 x 35-3/8" (1,1 x 29,2 x 89,9 cm) GAA 3/4" GAUGE BLOCK 7/16 x 23-7/8 x 23-7/8" (1,1 x 61 x 61 cm) Keep spacing between the center of the rafters at the lower edge of the panel and secure with one 2" nail into each rafter (Fig. A). Fig.
LOFT PANEL PARTS REQUIRED: x11 2" (5 cm) BEGIN 1 Complete installation of loft panel using 2" nails spaced 24" apart. FINISH You have finished your loft panel. DO OR 2 2" (5 cm) Nails Attention: Load not to exceed 400 lbs (181 kg) evenly distributed across Loft.
COLLAR TIES PARTS REQUIRED: x2 ¸1 x12 2" (5 cm) WO 1 x 4 x 72" (2,5 x 10 x 183 cm) BEGIN 2 Install collar tie WO on the two rafters closest to the door opening. Use three 2" nails at each side of collar tie. Collar ties should be flush to the roof panels. Ensure the collar ties are level before nailing. FINISH You have finished attaching your collar ties. DO OR 3 WO Flush Flush Flush Flush DOOR HINT: For best appearance, install collar ties on back side of rafters.
DOORS PARTS REQUIRED: x1 x2 OO 2 x 3 x 69" (5 x 7,6 x 175,3 cm) 1-1/4" (3 cm) x4 GAA 3" (7,6 cm) 3/4" GAUGE BLOCK HINT: x1 Left Door x1 Right Door Look for 3/8" SPACER attached to doors. BEGIN 1 Orient parts as shown on flat surface. 3/8" offset is to top. Look for red (right) and green (left) on hinge board. 2 Attach temporary support OO with 3" screws. Tighten securely. DO OR Attach temporary support GAA at bottom with 1-1/4" screws. Tighten securely.
DOORS x7 PARTS REQUIRED: x1 3" (7,6 cm) OO 2 x 3 x 69" (5 x 7,6 x 175,3 cm) Attach temporary support OO as a ledger board flush under wall panels for doors to rest on, using three 3" screws (Fig. A). DO OR 3 OO Flush against Fig. A wall panels. OO 4 Center doors on panel seam as shown (Fig. B). Check ledger board is still flush under panels. 5 Screw hinge boards into wall supports and floor using four 3" screws as shown. Make sure screws go into framing and floor (Fig. C, D).
DOORS PARTS REQUIRED: x38 3/4" (19 mm) BEGIN 1 Reinforce the door trim using 3/4" screws through door panel into trim (Fig. A). Locate screws as shown in Fig. B. Use two screws at seams. FINISH You have finished securing your doors. DO OR 2 Door Panel Install 3/4" screws from inside. Hinge Board Fig. A Door Trim 17-1/2" (44,5 cm) Approximately CENTER CENTER CENTER CENTER Two Screws Fig.
DOOR TRIM x8 PARTS REQUIRED: x2 2" (5 cm) ZJ 19/32 x 3 x 72" (15 mm x 7,6 x 183 cm) BEGIN 1 Center a ZJ over the Doors as shown. Secure with eight 2" finish nails 8" apart. FINISH You have finished installing your over door trim.
DOOR WEATHERSTRIP x14 PARTS REQUIRED: x2 2" (5 cm) OO 2 x 3 x 69" (5 x 7,6 x 175 cm) 1 With left door closed, center a weatherstrip OO vertically on the left door in the door opening (Fig. A). OO will offset the left door 1" OUT past the door trim 1" (Fig. B). 2 Secure OO using seven 3" screws through outside trim into OO (Fig. B) 3 On right door center OO vertically in door opening (Fig. A). OO will offset the right door 1" IN from the door trim (Fig. C).
DOOR HARDWARE PARTS REQUIRED: x1 x4 x1 1" (2,5 cm) x7 5/16" (0,8 cm) Drill Bi t 3/4" (1,9 cm) BEGIN 1 Place bolt onto OO in open position with bolt end 3/8" down from frame. Bolt is open when loop is contacting base (Fig A). 2 Install bolt with screws supplied and drill 5/16" hole for bolt to extend into. 3 Install hasp on right door and latch on left door. Bottom edge of hasp is 35-1/2" (90 cm) up from bottom edge of door trim.
WINDOW x14 PARTS REQUIRED: x1 12 x 12" (30,5 x 30,5 cm) Window x14 x2 EU 2" (5 cm) 3/4" (15 mm) 1 x 3 x 17" (2,5 x 7,6 x 43 cm) x2 DI 1 x 3 x 12" (2,5 x 7,6 x 30,5 cm) BEGIN 1 Caulk behind window flange and secure window in opening using 3/4" screws as shown. 2 Position EU and DI over window, and secure with 2" finish nails. 3 DO OR FINISH You have finished installing your window.
BATTENS x56 PARTS REQUIRED: 2" (5 cm) x8 1-3/4 x 3 x 72" (4,4 cm x 7,6 x 183 cm) BEGIN 1 Secure battens over wall studs and seams using 2" finish nails 12" apart. Repeat on other side. FINISH You have finished installing your battens .
PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: • Bottom edge of all siding and trim • Inside of doors and all 4 edges Note: Prime all un-primed exterior wood before painting.
SHINGLES - NOT INCLUDED • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. SHINGLE NAIL PATTERN Notch 1" (2,5 cm) 1/2" (1,3 cm) Notch Sealing Strip 1" (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS. BEGIN 1 Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle.
SHINGLES continued... 3 Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row. BACK OF SHED FRONT OF SHED Bend in roof 1" (2,5 cm) Notch Flush with rain slots. 4 Continue installing rows of shingles by staggering at front. Flush with rain slots. 1" (2,5 cm) Notch FRONT OF SHED 5 The shingle over the bend in the roof will be nailed down.
SHINGLES continued... 6 After shingles are installed over bend, nail down overlap using two roofing nails per tab. (2) Nails per tab 7 Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. Cut Off. 5" (12,7 cm) MAX. CUT Top of rain slot. 5" (12,7 cm) or less. • If more than 5" to rain slot you must install another row of shingles.
SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN 1 Cut shingles into THREE pieces. 2" (5 cm) Hint: Use cut-off pieces first. 2" (5 cm) 2" (5 cm) 2" (5 cm) 2" (5 cm) 2" (5 cm) Score shingle, then snap-off angled cut. Weather Seal Top of slot. Note: • You will need about 20 - 22 cut pieces. 2 20 to 22 Pieces Install first ridge cap flush to shingles at front, as shown. (1) Nail per side through weather seal.
SHINGLES - RIDGE CAP continued... 4 Continue installing ridge cap to back of roof. 5 Make sure there is 4" between the shingle-color and edge of shingles. 4" (10 cm) 6 Trim cap off flush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot. Cap 7 Install flush to shingles. Flush to shingles (2) Nails per side. FINISH 8 You have finished your ridge cap.
WARRANTY Backyard Storage Solutions, LLC warrants the following: Limited Conditional 1. Every product is warranted from defects in workmanship and manufacturing for one year. Warranty * 2. All hardware and metal components are warranted for two years. 3. Trim is warranted for 10 years. 4. Waferboard siding and sheathing is warranted for two years. 5. SmartSide™ siding is warranted for 10 years on all Marco series buildings and 15 years on all Premier Series buildings. 6.