Check hinge actuator motor is working.
Clutch worn, increase spring tension.
F11
Latch Actuator Fault, Lid fails to latch or unlatch within 4s.
Check that nothing is obstructing the lid.
Check latched and unlatched micro switches for continuity.
Check latch actuator motor is working.
F12
(Logged Only)
Hinge Actuator Current monitoring, an object has been detected that would interfere
with the lid closing.
F13
(Logged Only)
Latch Actuator Current monitoring, an object has been detected that would interfere
with the lid latching.
F14
(Logged Only)
Lid Closed Manually, Lid closed without foot pedal activation.
F15
Latch Actuator Current Monitoring (F13) triggered consecutively 3 times.
No indicators illuminated:
Power failure
No power to machine.
Check indicator membrane is connected properly.
Check fuses / electrical connections.