CASSETTE TYPE AIR CONDITIONER Indoor Unit Operation & Installation Manual AB094FAAHA AB124FAAHA AB184FCAHA AB244FCAHA AB424FCAHA AB484FCAHA No.0010576722A Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
Contents Cautions ........................................................................................... 1-5 Part name of the unit........................................................................ 6 Maintenance...................................................................................... 7-9 Trouble Shooting .......................................................................... 10-11 When Trouble Happens..................................................................
Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled.
Cautions All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Cautions Safety cautions Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. INSTRUCTIONS: These information can ensure the correct operation of the machine.
Cautions CAUTIONS! Don't operate the air-conditioner with damp hands. Otherwise will be shocked. Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged. Only use correctly-typed fuse.
Cautions Installation Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. WARNING ! Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. CAUTION ! Air-conditioner can't be installed in the environment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard. Connect earthing wire.
Introduction to Spare Parts Discharge unit (built in) In cooling operation, to discharge the water from inside the room.
Maintenance [Clean air filter] NOTE When having to clean, don't dismantle air-filter,otherwise may cause faults. In the environment where there is too much dust, air filter should be cleaned for more times. (about half a year one time) (B) Wash with water. With too much dust, use soft brush and neutral detergent. Swing off the water, and then place in cool place. 1. Open inlet grill 5. Install air filter Press the elliptical "PUSH" knob, the inlet grill will automatically drop.
Maintenance 2. Take off airfilter 3. Take of inlet grill [Dismantle and install swing plate ] 1. Fix the swing plate at the bottom. 2. Dismantle the swing plate. CAUTION! Use water to clean the plate and don't heavily scrub, otherwise the fine hair may fall off. Unscrew the screw at both ends of the swing plate. 4. Clean CAUTION! NOTE [Dismantle and install swing plate ] When the filter too much dust To spray the special detergent for vent fan or utensils. 3.
Maintenance Seasonal Reserve Post-season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency.
Trouble Shooting The followings are not malfuncition When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds Bi- Bi- or Godo-Godo. It is the flowing sound of the refrigerant , not a malfunction. Water flowing sound is heard Hua Hua Cracking sound is heard This is caused by heat expansion or contraction of plastics It smells. Air blown out from the indoor unit sometimes smells.
Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting This happens when the frost accumulated on the outdoor unit is removed (during defrosting operation). Water or vapor generated from the outdoor unit during heating. Defrosting operation During heating,indoor fan is still running even unit is stopped.
When Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Any obstacle exists at the air inlet or outlet? Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Door or window left opened ? Insufficient cooling Any other heat sources in the room? Sunlight direct into the room ? Too crowed in the room ? Cooled air blown out ( when heating) When the air conditioner does not operate properly after you have checked the above-mentioned items or whe
When Trouble Happens 1.
Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place. After installation ,please use the air conditioner according to the specification in the operation manual.
Installation Procedure Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil Following in the list are the accessories supplied with the unit,which can be used as required No.
Installation Procedure CAUTIONS: To ensure proper installation, read "Cautions" carefully before working. After installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed. WARNING! Installation shall be done by professional people, don't install unit by yourself.
Installation Procedure 1 BEFORE INSTALLATION 1. Determine the way to carry unit to installation place. Don't remove packing until unit reaches installation place. If unpacking is unavoidable, protect unit properly. 2 SELECTION OF INSTALLATION PLACE 2. (1) Installation place shall meet the following and agreed by customers: Place where proper air flow can be ensured. No block to air flow. Water drainage is smooth. Place strong enough to support unit .
Installation Procedure 3 PREPARATION FOR THE INSTALLATION 3. (1) Position of ceiling opening between unit and suspending bolt.
Installation Procedure 4 INSTALLATION OF INDOOR UNIT 4. In the case of new ceiling (1) Install unit temporarily Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket. (2) As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details. Center of the hole is marked on the paper pattern. Center of the unit is marked on the card in the unit and on the paper pattern. Mount paper pattern 5 onto unit using 3 screws 6 .
Installation Procedure 5. 5 REFRIGERANT PIPING (As for outdoor piping, please refer to installation Manual of outdoor unit.) Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant oil at both inside and outside of lflare nut. Tighten it band tight 3-4 turns then tighten it. Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).
Installation Procedures 7. 7 INSTALLING THE DECORATED BOARD ON THE BODY OF INDOOR UNIT As shown in Fig. 1, make the wind deflector motor of the decorated board face to the orifice of the indoor 6 unit, and then mount the decorated board onto the body of the indoor unit. 1 swing ring orifice location 2 2 deflector motor 3 4 Fig.1 Mounting the decorated board: a.
Installation Procedures Attention Inappropriate tightening of screws might cause the faults as shown in Fig. 3. Tighten the screws properly. air leakage If there is still a gap between the decorated board and the ceiling leakage after tightening the screws, please readjust the height of the body from roof of the indoor unit. (Fig.
Installation Procedures Mounting Air Inlet Grid and Angle Covers (1) Mounting the air inlet grid: Take care not to wind the lead of the wind deflector motor during mounting the air inlet grid. (2)For Model AB184-484FCAHA units, the angle covers should be mounted on the angles. ¢ ¢ Tie the thread of the angle cover onto the cleat on the decorated board as shown in Fig. 6. Mount the angle cover onto the decorated board (as shown in Fig. 7).
Installation Procedures Piping Materials & Heat Insulating Materials Piping Material Heat Insulating Material As to prevent condensation, heat insulating treatment should be performed. The heat insulating treatment for piping should be done respectively. Hard PVC tube VP31.5mm (inner bore) Vesicant polythene thickness: over 7mm Hose eccentricity adjustment (max.20mm) 20 The attached hoses can be used to adjust the eccentricity and angle of the hard PVC tube.
Installation Procedure Tubing Permissible Length & Height Difference Please refer to the attached manual of outdoor units. Tubing Materials & Specifications Model Tubing Size Gas pipe (mm) Liquid pipe Tubing Material AB094~ 124FAAHA AB184~ 244FCAHA AB424~ 484FCAHA 12.70 15.88 19.05 6.35 9.52 9.52 Phosphor deoxybronze seamless pipe (TP2) for air conditioner Refrigerant Filling Amount Add the refrigerant according to the installation instruction of outdoor unit.
Electrical Wiring Warning Electrical construction should be made with specific mains circuit by the qualified personnel according to the installation instruction. Electric shock and fire may be caused if the capacity of power supply is not sufficient. During arranging the wiring layout, specified cables should be used as the mains line, which accords with the local regulations on wiring.
Electrical Wiring Field setting Field setting the unit number Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for setting the indoor unit number and fan speed level on the computer board of the indoor unit.
Electrical Wiring The unit has temperature compensation function. (Only used for remote controller) You can use [swing] button of the remote controller to set or cancel temperature compensation function. (1) About temperature compensation function setting * The setting method for heating mode: press [ON/OFF] button of the remote controller to start the indoor unit, setting temperature: 24¡ , press [swing] button 7 times in 5 seconds, the buzzer will ring twice, and enter heating temp. compensation mode.
Technical Specifications Model AB094FAAHA AB124FAAHA A184FCAHA AB244FCAHA Power Supply 1PH.220V~,60Hz 1PH.220V~,60Hz 1PH.220V~,60Hz 1PH.