Capacity and power usage are measured under the assumption of indoor humidity of 46%
Capacity and power usage are measured under the assumption of indoor humidity of 46%
Heating Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-4
O
F (-20
O
C) 20,460 2,650 17,640 2,670 16,410 3,580
5
O
F (-15
O
C) 23,980 2,810 21,230 2,610 20,690 3,090
17
O
F (-8
O
C) 25,360 2,820 24,260 3,090 22,370 3,180
47
O
F (8
O
C) 37,580 3,180 36,500 3,330 34,250 3,460
Heating Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-4
O
F (-20
O
C) 18,970 2,170 15,640 2,450 14,330 2,370
5
O
F (-15
O
C) 23,020 2,760 20,040 2,870 17,530 2,920
17
O
F (-8
O
C) 25,300 2,890 23,320 3,170 21,750 3,250
47
O
F (8
O
C) 36,850 3,090 35,300 3,430 33,540 3,580
Cooling Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 25,410 1,850 26,900 1,880 30,520 1,900
65
O
F (18
O
C) 34,250 2,830 36,520 2,950 38,400 3,050
75
O
F (24
O
C) 33,760 2,940 34,700 3,010 36,580 3,150
85
O
F (29
O
C) 31,500 3,460 32,420 3,650 34,890 3,720
95
O
F (35
O
C) 32,100 3,680 33,540 3,780 35,100 3,950
105
O
F (41
O
C) 25,620 3,440 26,280 3,520 29,260 3,660
115
O
F (46
O
C) 22,200 3,050 23,680 3,180 25,380 3,250
Cooling Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 24,870 1,870 26,340 1,900 29,400 1,940
65
O
F (18
O
C) 34,120 2,780 35,790 2,860 36,850 2,980
75
O
F (24
O
C) 33,570 3,020 34,260 3,160 35,780 3,240
85
O
F (29
O
C) 30,840 3,490 31,580 3,630 33,520 3,750
95
O
F (35
O
C) 31,960 3,710 33,200 3,820 34,500 4,030
105
O
F (41
O
C) 25,130 3,480 25,430 3,610 28,460 3,850
115
O
F (46
O
C) 21,800 3,070 23,400 3,220 24,300 3,350