Manual
Table Of Contents
- SAFETY INSTRUCTIONS
- GETTING STARTED
- QUICK REFERENCE
- Menu Tree / Operation Shortcuts
- Convention
- Acquire Key
- Acquire Key - Segments
- Autoset Key
- CH1 ~ 4 Key
- Cursor Key
- Display Key
- Help Key
- Math Key
- Measure Key
- Hardcopy Key
- Run/Stop Key
- REF Key
- Save/Recall Key
- Test Key
- Test Key – Go-NoGo
- Trigger Type Menu
- Trigger Edge Menu
- Trigger Delay Menu
- Trigger Pulse Width Menu
- Trigger Video Menu
- Trigger Pulse Runt Menu
- Trigger Rise & Fall Menu
- Trigger Timeout Menu
- Utility Key
- Utility Key – I/O
- Utility Key – File Utilities
- Utility Key – Wave Generator - Demo Outputs
- Search - Edge
- Search – Pulse Width
- Search - Runt
- Search – Rise/Fall Time
- Zoom Key
- Option Key
- Default Settings
- Built-in Help
- Menu Tree / Operation Shortcuts
- MEASUREMENT
- CONFIGURATION
- OPTIONAL SOFTWARE and APPS.
- SAVE/RECALL
- FILE UTILITIES
- HARDCOPY KEY
- REMOTE CONTROL CONFIG
- MAINTENANCE
- FAQ
- I connected the signal but it does not appear on the display.
- I want to remove the (Measurement result / FFT result / Help contents) from the display.
- The waveform does not update (frozen).
- The probe waveform is distorted.
- Autoset does not catch the signal well.
- I can’t save files to the internal memory.
- The display image printout is too dark on the background.
- The date and time settings are not correct.
- The accuracy does not match the specification.
- APPENDIX
- INDEX
GDS-2000A Series User Manual
188
entire long memory length (See page 109 for
information on the record length). All points are
recorded as integers.
Note, however, that only fast CSV can be recalled
to the internal memory. Detailed CSV, LM Fast
CSV and LM Detailed CSV cannot be recalled.
Waveform Type
CH1 ~ 4
Input channel signal
Ref1~4
Reference waveform
Math
Math operation result (page 93)
D0~D15
Digital channels
All
Displayed
All the waveforms on the display.
Contents:
Detail CSV
&
LM Detail CSV
Detail CSV waveform data contains channel
information such as vertical and horizontal
position of a signal for 5000 points.
The following information is included in Detail
CSV, where applicable:
Format (scope type)
Memory length
Trigger Level
Source
Label
Probe ratio
Vertical units
Vertical scale
Vertical position
Horizontal units
Horizontal scale
Horizontal position
Horizontal mode
Sampling period
Firmware
Time
Mode
Vertical data
Horizontal data
Contents:
Fast CSV
The following information is included in the Fast
CSV waveform files, where applicable: